1SDA057015R1 ABB E6H 6300 PR123/P-LSIG 6300A 3P Fixed Air Circuit Breaker

1SDA057015R1 ABB E6H 6300 PR123/P-LSIG 6300A 3P Fixed Air Circuit Breaker

ABB 1SDA057015R1 is a SACE Emax E6H 6300 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR123/P-LSIG R6300 electronic release providing long-time, short-time, instantaneous and earth-fault protection.

SKU: 1SDA057015R1MPN: 1SDA057015R1
Price
List Price £87,700.13 ex VAT
Your Price (ex VAT) Save 25%
£65,775.10 25% OFF
You save £21,925.03 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £65,775.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£65,775.10

Why Choose the ABB E6H 6300 PR123/P-LSIG 6300A 3P Fixed Air Circuit Breaker?

The ABB 1SDA057015R1 is a high-performance SACE Emax E6H air circuit breaker designed for protection and switching in high-current low-voltage electrical distribution systems. Rated at 6300 A, this three-pole fixed breaker incorporates an ABB PR123/P-LSIG R6300 electronic overcurrent release providing long-time, short-time, instantaneous and earth-fault protection.

As part of the proven ABB SACE Emax series, the E6H 6300 is engineered for demanding industrial, infrastructure and commercial power distribution applications. Its fixed construction with rear horizontal terminals provides a robust connection arrangement for permanent integration into high-capacity low-voltage switchboards.

With a rated operational voltage of 690 V AC and ultimate and service short-circuit breaking capacities of 100 kA up to 690 V AC, the E6H platform is suited to installations with substantial prospective fault currents. The advanced PR123/P-LSIG trip unit combines comprehensive LSIG protection with the monitoring capabilities required for critical high-current distribution systems.

Key Advantages

  • High-current 6300 A SACE Emax air circuit breaker for major power distribution systems.
  • Three-pole configuration for three-phase electrical networks.
  • Advanced PR123/P-LSIG R6300 electronic overcurrent release.
  • LSIG functionality provides long-time, short-time, instantaneous and earth-fault protection.
  • 100 kA ultimate and service breaking capacity up to 690 V AC.
  • 100 kA short-time withstand current for 1 s.
  • Fixed construction with rear horizontal terminals for robust switchboard integration.
  • Four auxiliary contacts and open/closed position indication support signalling and control systems.

Key Features

  • ABB SACE Emax E6H air circuit breaker platform.
  • 6300 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed execution.
  • Rear horizontal terminals.
  • PR123/P-LSIG R6300 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Earth-fault protection.
  • 690 V AC rated operational voltage.
  • Four auxiliary contacts with open/closed circuit-breaker position indication.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E6H provide switching and overcurrent protection for major low-voltage distribution circuits. The electronic trip unit monitors electrical conditions and initiates circuit-breaker operation when configured overload, short-circuit or earth-fault thresholds are exceeded, helping protect busbars, cables, transformers and connected electrical equipment.

The PR123/P-LSIG release combines long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection in an advanced electronic trip unit. Together with the E6H frame's 6300 A current rating and high short-circuit performance, it provides comprehensive protection for critical industrial and infrastructure distribution networks.

Typical Applications

  • Main incoming circuit breakers in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current feeder protection.
  • Transformer secondary protection and switching.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Generator and utility distribution systems.
  • Fixed switchboard installations requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax
Frame / type E6H
ABB order code 1SDA057015R1
EAN 8015644583552
Product type Air circuit breaker
Execution Fixed
Terminal connection Rear horizontal
Number of poles 3
Rated current (In) 6300 A
Rated uninterrupted current (Iu) 6300 A
Rated operational current (Ie) 6300 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Trip unit PR123/P-LSIG R6300
Release type Electronic
Protection functions LSIG – long-time, short-time, instantaneous and earth-fault
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 100 kA
Short-time withstand current (Icw), 1 s 100 kA
Short-time withstand current (Icw), 3 s 85 kA
Power loss 650 W
Electrical durability 2000 cycles at Ue ≤ 440 V; 1500 cycles at 500–690 V
Mechanical durability 12000 cycles
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Product net dimensions (W × H × D) 782 × 418 × 302 mm
Product net weight 112 kg
Standard IEC
Product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA057015R1?

The ABB 1SDA057015R1 is a SACE Emax E6H 6300 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR123/P-LSIG R6300 electronic overcurrent release.

What protection functions does the PR123/P-LSIG trip unit provide?

The PR123/P-LSIG electronic release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB E6H 6300?

The E6H 6300 provides ultimate and service short-circuit breaking capacities of 100 kA at both 415 V AC and 690 V AC, together with a short-time withstand current of 100 kA for 1 s.

How many poles does the ABB 1SDA057015R1 have?

This E6H circuit breaker has three poles for switching and protecting high-current three-phase electrical distribution systems.

Is the ABB 1SDA057015R1 fixed or withdrawable?

The 1SDA057015R1 is a fixed circuit breaker equipped with rear horizontal terminals for permanent integration into a compatible low-voltage switchboard.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for reliable protection and switching in demanding low-voltage power distribution systems, combining high-current capability, advanced electronic protection and robust switchboard integration.