1SDA056887R1 ABB E4V3200 PR123/P-LSIG 3200 A 3-Pole Fixed Air Circuit Breaker

1SDA056887R1 ABB E4V3200 PR123/P-LSIG 3200 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA056887R1 E4V3200 is a 3200 A three-pole fixed SACE Emax air circuit breaker with a PR123/P-LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection for demanding high-current low-voltage power distribution systems.

SKU: 1SDA056887R1MPN: 1SDA056887R1
Price
List Price £39,695.60 ex VAT
Your Price (ex VAT) Save 25%
£29,771.70 25% OFF
You save £9,923.90 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29,771.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£29,771.70

Why Choose the ABB E4V3200 PR123/P-LSIG Air Circuit Breaker?

The ABB 1SDA056887R1 is a high-performance SACE Emax E4V air circuit breaker designed for switching and comprehensive protection in high-current low-voltage electrical distribution systems. Identified as E4V3200 PR123/P-LSIG, this three-pole fixed circuit breaker combines a 3200 A rated current with ABB's advanced PR123/P-LSIG electronic overcurrent release.

As part of the ABB SACE Emax / New Emax range, the E4V3200 is engineered for installations with very high prospective fault currents. Its V short-circuit performance level provides ultimate and service short-circuit breaking capacities of 150 kA at 400 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC. The fixed construction uses rear horizontal terminals for permanent integration into compatible low-voltage switchboards.

The integrated PR123/P-LSIG R3200 electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. With a rated operational voltage of 690 V AC, three-pole configuration and 3200 A rated uninterrupted current, the 1SDA056887R1 is well suited to critical main incoming, feeder and distribution protection duties requiring very high breaking capacity and comprehensive electronic protection.

Key Advantages

  • High-capacity 3200 A air circuit breaker for demanding low-voltage power distribution.
  • Three-pole configuration designed for three-phase electrical systems.
  • Advanced PR123/P-LSIG R3200 electronic trip unit with comprehensive LSIG protection.
  • Exceptional 150 kA Icu and Ics at 400 V AC short-circuit breaking performance.
  • Maintains 130 kA Icu and Ics at 500 V AC and 100 kA at 690 V AC.
  • 100 kA short-time withstand current for 1 s and 75 kA for 3 s.
  • Integrated ground-fault protection for enhanced electrical system protection.
  • Fixed construction with rear horizontal terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax E4V series.
  • 3200 A rated operational and uninterrupted current.
  • Three-pole circuit breaker configuration.
  • PR123/P-LSIG R3200 electronic overcurrent release.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated ground-fault (G) protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 150 kA Icu and Ics at 400 V AC.
  • 100 kA Icu and Ics at 690 V AC.
  • Fixed design with rear horizontal terminals.
  • Fitted with four auxiliary contacts and open/closed position indication.

Advanced High-Breaking-Capacity LSIG Protection

The ABB E4V3200 is designed for low-voltage distribution systems where very high prospective fault currents require substantial interruption capability. Its V performance level delivers ultimate and service short-circuit breaking capacities of 150 kA from 220–440 V AC, 130 kA at 500 V AC and 100 kA at 660–690 V AC, together with a short-time withstand capability of 100 kA for 1 s.

The advanced PR123/P-LSIG electronic release combines long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This comprehensive protection arrangement enables the 1SDA056887R1 to protect conductors, busbars, switchgear and connected equipment against a wide range of electrical fault conditions while supporting selective protection strategies in appropriately engineered power distribution systems.

Typical Applications

  • Main incoming circuit protection in high-current low-voltage switchboards.
  • Industrial power distribution systems with very high prospective fault currents.
  • Transformer secondary distribution and protection.
  • Protection of high-current distribution feeders and busbar systems.
  • Electrical systems requiring integrated ground-fault protection.
  • Large commercial and infrastructure electrical installations.
  • Manufacturing plants and process facilities.
  • High-fault-level switchgear and critical power distribution assemblies.

Technical Specifications

Series SACE Emax / New Emax
Product group 310513-New Emax
Extended product type E4V3200PR123/P-LSIGIn=3200A3pFHR
ABB order code 1SDA056887R1
Product type Air circuit breaker
Frame E4
Short-circuit performance level V
Rated current (In) 3200 A
Rated operational current (Ie) 3200 A
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Current type AC
Trip unit PR123/P-LSIG
Trip unit rating R3200
Trip unit type Electronic
Protection functions L, S, I and G
Overload release setting range 1250–3200 A
Ultimate short-circuit breaking capacity (Icu) at 220 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 220 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 230 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 230 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 380 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 130 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 130 kA
Ultimate short-circuit breaking capacity (Icu) at 660 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 660 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Installation type Fixed
Terminal connection Rear horizontal
Version F
Auxiliary contacts 4
Position indication Open / closed
Mechanical endurance 15,000 operations
Electrical endurance at ≤440 V AC 7,000 operations
Electrical endurance at 500–690 V AC 7,000 operations
Power loss 235 W
Net weight 95 kg
Standard IEC
EAN 8015644582272
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA056887R1 used for?

The ABB 1SDA056887R1 is a 3200 A three-pole fixed air circuit breaker used for switching and protecting high-current low-voltage electrical distribution systems, particularly where very high short-circuit breaking capacity is required.

What trip unit is fitted to the ABB E4V3200?

This circuit breaker is fitted with the ABB PR123/P-LSIG R3200 electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.

What does LSIG mean on the PR123/P-LSIG trip unit?

LSIG denotes long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection, providing comprehensive protection against multiple electrical fault conditions.

What is the breaking capacity of the ABB E4V3200?

The E4V3200 has ultimate and service short-circuit breaking capacities of 150 kA at 400 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC, together with rated short-time withstand currents of 100 kA for 1 s and 75 kA for 3 s.

Is the ABB 1SDA056887R1 fixed or withdrawable?

The 1SDA056887R1 is a fixed three-pole SACE Emax air circuit breaker with rear horizontal terminals, designed for permanent installation within compatible low-voltage switchboards and distribution assemblies.

Trusted ABB Power Distribution Protection

ABB SACE Emax air circuit breakers are designed for demanding low-voltage power distribution applications, combining very high breaking performance, advanced electronic trip protection and robust construction for dependable high-current electrical system protection.