Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056874R1 E4H4000 PR121/P-LSIG is a 4000 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LSIG R4000 electronic release providing long-time, short-time, instantaneous and earth-fault protection.
£39,600.23
The ABB E4H4000 PR121/P-LSIG, order code 1SDA056874R1, is a high-performance SACE Emax E4H air circuit breaker moving part designed for protection and switching in high-current low-voltage electrical distribution systems. Rated at 4000 A, this four-pole withdrawable configuration combines the robust ABB SACE Emax platform with a PR121/P-LSIG R4000 electronic overcurrent release.
The PR121/P-LSIG release provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection, delivering comprehensive protection against overload, short-circuit and earth-fault conditions. This combination supports selective protection and dependable fault management for main feeders, busbars and other critical circuits in demanding power-distribution networks.
This configuration is supplied as the four-pole withdrawable moving part of the E4H4000 circuit breaker and is designed for use with the corresponding ABB SACE Emax fixed part. The E4H performance level provides an ultimate short-circuit breaking capacity of 100 kA from 400 V to 500 V AC and 85 kA at 690 V AC, while the withdrawable construction facilitates inspection, servicing and replacement.
The ABB SACE Emax E4H platform is designed for high-capacity low-voltage distribution systems where substantial short-circuit performance and comprehensive electronic protection are required. The PR121/P-LSIG release combines long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, helping safeguard busbars, feeders and connected electrical equipment while supporting coordinated system protection.
The withdrawable E4H4000 configuration is particularly suitable for switchboards where serviceability and operational flexibility are important. The circuit-breaker moving part can be withdrawn from its corresponding fixed part for inspection, maintenance or replacement, while its 4000 A rating and up to 100 kA ultimate short-circuit breaking capacity make it suitable for demanding industrial, commercial and infrastructure distribution systems.
| Series | SACE Emax E4H |
|---|---|
| ABB order code | 1SDA056874R1 |
| Product group | 310513-New Emax |
| Product type | Air circuit breaker moving part |
| Rated current (In) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Number of poles | 4 |
| Execution | Withdrawable |
| Component | Moving part |
| Protection release | PR121/P-LSIG R4000 |
| Release technology | Electronic |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) and earth-fault (G) |
| Rated operational voltage | 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Short-circuit performance level | H |
| Overload release adjustment range | 1250–4000 A |
| Short-time delayed short-circuit adjustment range | 4000–40000 A |
| Instantaneous short-circuit adjustment range | 6000–60000 A |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Weight | 116 kg |
| Standard | IEC |
| EAN | 8015644582142 |
| HS code | 85362090 |
The ABB 1SDA056874R1 is the withdrawable moving part of an E4H4000 SACE Emax air circuit breaker rated at 4000 A, with four poles and a PR121/P-LSIG R4000 electronic overcurrent release.
The ABB E4H4000 PR121/P-LSIG 1SDA056874R1 has a rated uninterrupted current of 4000 A.
The PR121/P-LSIG electronic release provides long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and earth-fault protection (G).
ABB 1SDA056874R1 is a withdrawable circuit-breaker moving part designed for use with the corresponding ABB SACE Emax fixed part.
The E4H4000 provides an ultimate short-circuit breaking capacity of 100 kA from 400 V to 500 V AC and 85 kA at 690 V AC.
Yes. Its PR121/P-LSIG electronic release includes the G protection function for earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable high-current switching, comprehensive electronic protection, high short-circuit performance and serviceable withdrawable construction are required.