ABB 1SDA056867R1 E4H4000 is a 4000 A three-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LI electronic trip unit providing long-time overload and instantaneous short-circuit protection for demanding high-current low-voltage power distribution systems.
£33,017.98
The ABB 1SDA056867R1 is a high-performance SACE Emax E4H air circuit breaker moving part designed for switching and protection in high-current low-voltage electrical distribution systems. Identified as E4H4000 PR122/P-LI, this three-pole withdrawable circuit breaker combines a 4000 A rated current with ABB's PR122/P-LI electronic overcurrent release for dependable overload and instantaneous short-circuit protection.
As part of the ABB SACE Emax / New Emax range, the E4H4000 is engineered for demanding industrial, commercial and infrastructure power distribution applications. Its H short-circuit performance level provides an ultimate and service short-circuit breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC, together with a rated short-time withstand current of 100 kA for 1 s.
The integrated PR122/P-LI R4000 electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. With a rated operational voltage of 690 V AC, three-pole configuration and withdrawable moving-part construction, the 1SDA056867R1 is well suited to main incoming and distribution protection duties where high fault-current performance and convenient circuit breaker servicing are required.
Air circuit breakers such as the ABB E4H4000 provide switching and protection for high-current low-voltage distribution systems. The E4H performance level is designed for installations with substantial prospective fault currents, providing both ultimate and service short-circuit breaking capacities of 100 kA through the 220–500 V AC range and 85 kA at 660–690 V AC.
The PR122/P-LI electronic release provides long-time overload and instantaneous short-circuit protection, helping protect cables, busbars, switchgear and connected equipment against sustained overloads and severe fault currents. Combined with its 4000 A rating and withdrawable moving-part construction, the 1SDA056867R1 is suitable for major switchboards and industrial distribution systems where high fault-current capability and maintainability are important requirements.
| Series | SACE Emax / New Emax |
|---|---|
| Product group | 310513-New Emax |
| Extended product type | E4H4000PR122/P-LIIn=4000A3pWMP |
| ABB order code | 1SDA056867R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4 |
| Short-circuit performance level | H |
| Rated current (In) | 4000 A |
| Rated operational current (Ie) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | PR122/P-LI |
| Trip unit rating | R4000 |
| Trip unit type | Electronic |
| Protection functions | L and I |
| Ultimate short-circuit breaking capacity (Icu) at 220 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 220 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 230 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 230 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 380 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 380 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 415 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 500 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 660 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 660 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Installation type | Withdrawable |
| Component type | Moving part (MP) |
| Version | W |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Mechanical endurance | 15,000 operations |
| Electrical endurance at ≤440 V AC | 5,000 operations |
| Electrical endurance at 500–690 V AC | 4,000 operations |
| Power loss | 660 W |
| Dimensions (W × H × D) | 594 × 461 × 396.5 mm |
| Net weight | 85 kg |
| Standard | IEC |
| EAN | 8015644582074 |
| Customs tariff number | 85362090 |
The ABB 1SDA056867R1 is a 4000 A three-pole withdrawable air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution systems.
This circuit breaker is fitted with the ABB PR122/P-LI R4000 electronic trip unit, providing long-time overload and instantaneous short-circuit protection.
The circuit breaker has a rated operational and uninterrupted current of 4000 A.
The E4H4000 has ultimate and service short-circuit breaking capacities of 100 kA at 400 V AC and 85 kA at 690 V AC, together with a rated short-time withstand current of 100 kA for 1 s and 75 kA for 3 s.
Yes. The 1SDA056867R1 is a withdrawable three-pole SACE Emax circuit breaker moving part designed for use with the corresponding fixed part, supporting convenient inspection, servicing and replacement.
ABB SACE Emax air circuit breakers are designed for demanding low-voltage power distribution applications, combining high breaking performance, electronic protection and serviceable withdrawable construction for dependable high-current electrical system protection.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.