Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056860R1 E4H4000 is a 4000 A four-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR122/P-LSI R4000 electronic release providing long-time, short-time and instantaneous overcurrent protection.
£33,698.32
The ABB E4H4000 PR122/P-LSI, order code 1SDA056860R1, is a high-performance SACE Emax air circuit breaker designed for switching and overcurrent protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole fixed circuit breaker combines a 4000 A rated uninterrupted current with the PR122/P-LSI R4000 electronic overcurrent release.
The PR122/P-LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These LSI functions help protect high-current conductors, busbars, switchboards and connected equipment against sustained overloads and short circuits while supporting selective protection and coordinated fault clearing across complex power-distribution networks.
This configuration is a four-pole fixed circuit breaker equipped with rear horizontal terminals. Its E4H high short-circuit performance level provides an ultimate breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC, making it suitable for installations with substantial prospective fault currents.
The ABB SACE Emax E4H4000 is engineered for switching and protection at main incomer, bus-coupler and high-current feeder levels within substantial low-voltage distribution systems. Its PR122/P-LSI electronic release combines long-time protection against sustained overloads, short-time protection for coordinated fault clearing and instantaneous intervention against severe short-circuit currents.
The combination of a 4000 A current rating, four-pole construction and 100 kA short-circuit breaking capacity at 400 V AC makes the 1SDA056860R1 particularly suitable for installations with high prospective fault currents. Its fixed construction and rear horizontal terminals provide permanent switchboard integration, while the auxiliary contacts provide useful status information for associated monitoring, signalling and control systems.
| Product group | New Emax |
|---|---|
| Series | SACE Emax E4 |
| ABB order code | 1SDA056860R1 |
| Extended product type | E4H4000PR122/P-LSIIn=4000A4pFHR |
| Catalog description | E4H 4000 PR122/P-LSI In=4000A 4p F HR |
| Product type | Air circuit breaker |
| Frame | E4 |
| Short-circuit performance level | H |
| Rated current (In) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Number of poles | 4P |
| Current type | AC |
| Release | PR122/P-LSI R4000 |
| Release type | Electronic overcurrent release |
| Protection functions | LSI — long-time, short-time and instantaneous |
| Long-time overload protection | Yes |
| Short-time short-circuit protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Integrated earth-fault protection | No |
| Version | Fixed |
| Terminal connection | Rear horizontal |
| Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 230 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Electrical durability at Ue ≤ 440 V | 5000 cycles |
| Electrical durability at Ue 500–690 V | 4000 cycles |
| Electrical operating frequency | 10 cycles per hour |
| Mechanical durability | 15,000 cycles |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Product width | 656 mm |
| Product height | 418 mm |
| Product depth | 302 mm |
| Product net weight | 92 kg |
| EAN | 8015644582005 |
| HS code | 85362090 |
| Standard | IEC |
The ABB 1SDA056860R1 is a 4000 A four-pole SACE Emax air circuit breaker designed for switching and LSI overcurrent protection in demanding high-current, high-fault-level low-voltage power-distribution systems.
This circuit breaker is fitted with the ABB PR122/P-LSI R4000 electronic overcurrent release, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.
The ABB E4H4000 PR122/P-LSI has a rated uninterrupted current of 4000 A.
The 1SDA056860R1 is a four-pole fixed circuit breaker equipped with rear horizontal terminals for permanent installation within a compatible low-voltage switchboard.
LSI denotes long-time overload, short-time short-circuit and instantaneous short-circuit protection. This release configuration does not incorporate the G earth-fault protection function found on PR122/P-LSIG versions.
ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, high short-circuit performance and configurable electronic protection for critical electrical infrastructure.
We use cookies