ABB 1SDA056843R1 E4H3200 is a 3200 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LI R3200 electronic release providing long-time overload and instantaneous short-circuit protection.
£32,158.13
The ABB E4H3200 PR122/P-LI, order code 1SDA056843R1, is a high-performance SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole withdrawable configuration combines a 3200 A rated uninterrupted current with the PR122/P-LI R3200 electronic overcurrent release.
The PR122/P-LI release provides long-time overload and instantaneous short-circuit protection. These LI functions help protect high-current conductors, busbars, switchboards and connected equipment against sustained overload conditions and severe short-circuit faults, making the breaker suitable for major industrial and infrastructure power-distribution networks.
This model is the four-pole withdrawable moving part of the E4H3200 circuit breaker and is designed for use with the corresponding ABB SACE Emax fixed part. Its H short-circuit performance level provides an ultimate breaking capacity of 100 kA at 400 V AC, while the breaker includes four auxiliary contacts and open/closed position indication for switchboard signalling and control.
The ABB SACE Emax E4H3200 is engineered for switching and protection at main incomer and high-current feeder levels within substantial low-voltage distribution systems. Its PR122/P-LI electronic release provides long-time protection against sustained overloads together with instantaneous intervention against severe short-circuit currents, helping protect conductors, switchboards and connected electrical equipment.
The combination of a 3200 A current rating, four-pole construction and 100 kA short-circuit breaking capacity at 400 V AC makes the 1SDA056843R1 particularly suitable for installations with high prospective fault currents. Its withdrawable moving-part construction supports serviceability by allowing the breaker to be used with the corresponding fixed part in switchboards where inspection, maintenance and equipment availability are important.
| Product group | New Emax |
|---|---|
| Series | SACE Emax E4 |
| ABB order code | 1SDA056843R1 |
| Extended product type | E4H3200PR122/P-LIIn=3200A4pWMP |
| Catalog description | E4H 3200 PR122/P-LI In=3200A 4p W MP |
| Product type | Air circuit breaker moving part |
| Frame | E4 |
| Short-circuit performance level | H |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Number of poles | 4P |
| Release | PR122/P-LI R3200 |
| Release type | Electronic overcurrent release |
| Protection functions | LI — long-time and instantaneous |
| Long-time overload protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Short-time protection function | No |
| Integrated earth-fault protection | No |
| Version | Withdrawable moving part |
| Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 230 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| EAN | 8015644581831 |
| Standard | IEC |
The ABB 1SDA056843R1 is a 3200 A four-pole SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in high-current, high-fault-level low-voltage power-distribution systems.
This circuit breaker is fitted with the ABB PR122/P-LI R3200 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.
The circuit breaker has a rated uninterrupted current of 3200 A.
The 1SDA056843R1 is a four-pole withdrawable moving part designed for use with the corresponding ABB SACE Emax fixed part.
LI denotes long-time overload and instantaneous short-circuit protection. This configuration does not incorporate the S short-time or G earth-fault protection functions found on LSI and LSIG release configurations.
ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, high short-circuit performance and service-friendly withdrawable construction for critical electrical infrastructure.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.