1SDA056843R1 ABB E4H3200 PR122/P-LI 3200 A 4-Pole Withdrawable Air Circuit Breaker

1SDA056843R1 ABB E4H3200 PR122/P-LI 3200 A 4-Pole Withdrawable Air Circuit Breaker

ABB 1SDA056843R1 E4H3200 is a 3200 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LI R3200 electronic release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056843R1MPN: 1SDA056843R1
Price
List Price £42,877.50 ex VAT
Your Price (ex VAT) Save 25%
£32,158.13 25% OFF
You save £10,719.38 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £32,158.13
Trade pricing is personalised to your account

Manufacturer Lead Time

£32,158.13

Why Choose the ABB E4H3200 PR122/P-LI Air Circuit Breaker?

The ABB E4H3200 PR122/P-LI, order code 1SDA056843R1, is a high-performance SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole withdrawable configuration combines a 3200 A rated uninterrupted current with the PR122/P-LI R3200 electronic overcurrent release.

The PR122/P-LI release provides long-time overload and instantaneous short-circuit protection. These LI functions help protect high-current conductors, busbars, switchboards and connected equipment against sustained overload conditions and severe short-circuit faults, making the breaker suitable for major industrial and infrastructure power-distribution networks.

This model is the four-pole withdrawable moving part of the E4H3200 circuit breaker and is designed for use with the corresponding ABB SACE Emax fixed part. Its H short-circuit performance level provides an ultimate breaking capacity of 100 kA at 400 V AC, while the breaker includes four auxiliary contacts and open/closed position indication for switchboard signalling and control.

Key Advantages

  • High-current 3200 A SACE Emax air circuit breaker moving part.
  • PR122/P-LI R3200 electronic release provides long-time overload and instantaneous short-circuit protection.
  • Four-pole configuration supports three-phase distribution systems requiring neutral switching.
  • Withdrawable construction facilitates inspection, maintenance and servicing within compatible switchgear.
  • 100 kA ultimate short-circuit breaking capacity at 400 V AC suits high-fault-level installations.
  • 85 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding power-distribution applications.
  • Four auxiliary contacts and open/closed indication support switchboard signalling and control.

Key Features

  • ABB SACE Emax E4H3200 air circuit breaker moving part.
  • 3200 A rated uninterrupted current.
  • Four-pole withdrawable version.
  • PR122/P-LI R3200 electronic overcurrent release.
  • L protection: long-time overload protection.
  • I protection: instantaneous short-circuit protection.
  • H short-circuit performance level.
  • 100 kA Icu at 400 V AC.
  • 85 kA Icu at 690 V AC.
  • 100 kA Icw for 1 s.
  • 75 kA Icw for 3 s.
  • Withdrawable moving-part construction for service-friendly switchgear installations.
  • Four auxiliary contacts for signalling and control.
  • Integrated circuit-breaker open/closed position indication.

Reliable LI Protection for High-Fault-Level Power Distribution

The ABB SACE Emax E4H3200 is engineered for switching and protection at main incomer and high-current feeder levels within substantial low-voltage distribution systems. Its PR122/P-LI electronic release provides long-time protection against sustained overloads together with instantaneous intervention against severe short-circuit currents, helping protect conductors, switchboards and connected electrical equipment.

The combination of a 3200 A current rating, four-pole construction and 100 kA short-circuit breaking capacity at 400 V AC makes the 1SDA056843R1 particularly suitable for installations with high prospective fault currents. Its withdrawable moving-part construction supports serviceability by allowing the breaker to be used with the corresponding fixed part in switchboards where inspection, maintenance and equipment availability are important.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-fault-level industrial power-distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary and main incomer protection.
  • High-current feeder protection.
  • Withdrawable switchgear and power-distribution assemblies.

Technical Specifications

Product group New Emax
Series SACE Emax E4
ABB order code 1SDA056843R1
Extended product type E4H3200PR122/P-LIIn=3200A4pWMP
Catalog description E4H 3200 PR122/P-LI In=3200A 4p W MP
Product type Air circuit breaker moving part
Frame E4
Short-circuit performance level H
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Number of poles 4P
Release PR122/P-LI R3200
Release type Electronic overcurrent release
Protection functions LI — long-time and instantaneous
Long-time overload protection Yes
Instantaneous short-circuit protection Yes
Short-time protection function No
Integrated earth-fault protection No
Version Withdrawable moving part
Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 230 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 660 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Auxiliary contacts 4
Position indication Open / closed
EAN 8015644581831
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056843R1 used for?

The ABB 1SDA056843R1 is a 3200 A four-pole SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in high-current, high-fault-level low-voltage power-distribution systems.

What protection release is fitted to the ABB E4H3200?

This circuit breaker is fitted with the ABB PR122/P-LI R3200 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.

What is the rated current of the ABB E4H3200 PR122/P-LI?

The circuit breaker has a rated uninterrupted current of 3200 A.

Is the ABB 1SDA056843R1 fixed or withdrawable?

The 1SDA056843R1 is a four-pole withdrawable moving part designed for use with the corresponding ABB SACE Emax fixed part.

What does LI mean on the PR122/P release?

LI denotes long-time overload and instantaneous short-circuit protection. This configuration does not incorporate the S short-time or G earth-fault protection functions found on LSI and LSIG release configurations.

Trusted Protection for Industrial Power Systems

ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, high short-circuit performance and service-friendly withdrawable construction for critical electrical infrastructure.