1SDA056804R1 ABB E4S4000PR122/P-LSI 4000A 3-Pole Air Circuit Breaker Moving Part

1SDA056804R1 ABB E4S4000PR122/P-LSI 4000A 3-Pole Air Circuit Breaker Moving Part

ABB 1SDA056804R1 E4S4000PR122/P-LSI is a 4000 A three-pole withdrawable SACE Emax air circuit breaker moving part with PR122/P-LSI R4000 electronic protection, a 690 V AC rating and 75 kA short-circuit breaking capacity.

SKU: 1SDA056804R1MPN: 1SDA056804R1
Price
List Price £40,865.52 ex VAT
Your Price (ex VAT) Save 25%
£30,649.14 25% OFF
You save £10,216.38 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £30,649.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£30,649.14

Why Choose the ABB E4S4000PR122/P-LSI 4000A Air Circuit Breaker?

The ABB E4S4000PR122/P-LSI, order code 1SDA056804R1, is a high-performance 4000 A three-pole air circuit breaker moving part designed for reliable switching and protection in demanding low-voltage electrical distribution systems. As part of the proven ABB SACE Emax E4 series, this withdrawable configuration combines the E4S short-circuit performance class with the advanced PR122/P electronic overcurrent protection release.

The breaker is equipped with an ABB PR122/P-LSI R4000 electronic overcurrent release, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. These LSI functions provide comprehensive overcurrent protection and support selective coordination in industrial switchboards, transformer secondary systems, main distribution assemblies and other critical high-current installations.

With a rated current of 4000 A, a three-pole withdrawable moving-part configuration and a rated operational voltage of 690 V AC, the E4S4000PR122/P-LSI is engineered for installations where high current capacity, maintainability and service continuity are important. The E4S platform provides an ultimate short-circuit breaking capacity of 75 kA up to 690 V AC and a rated short-time withstand current of 75 kA.

Key Advantages

  • High-capacity 4000 A air circuit breaker moving part for demanding low-voltage power distribution.
  • Three-pole withdrawable configuration supports convenient servicing, inspection and replacement.
  • Advanced PR122/P-LSI R4000 electronic protection release.
  • Long-time, short-time and instantaneous protection supports effective selective coordination.
  • 75 kA ultimate and service short-circuit breaking capacity at voltages up to 690 V AC.
  • 75 kA rated short-time withstand current for both 1 s and 3 s.
  • Fitted with four auxiliary contacts for breaker status and control circuits.
  • Integrated open/closed position indication supports monitoring and signalling.

Key Features

  • ABB SACE Emax E4S air circuit breaker platform.
  • 4000 A rated uninterrupted current.
  • Three-pole construction.
  • Withdrawable moving part (W MP) configuration.
  • PR122/P-LSI R4000 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 75 kA Icu at 400/415 V AC.
  • 75 kA Icu at 690 V AC.
  • 75 kA Icw for 1 s and 3 s.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary contacts and breaker open/closed position indication.
  • IEC-compliant air circuit breaker design.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E4 protect low-voltage electrical networks against damaging overcurrents while providing dependable switching and isolation of high-current circuits. Their robust construction, high short-circuit withstand capability and electronic protection technology make them particularly suitable for main incomers, transformer secondaries, large feeders and other critical power distribution circuits.

The PR122/P electronic release monitors circuit current and initiates breaker operation when configured protection thresholds are exceeded. In this LSI configuration, long-time protection responds to sustained overloads, short-time protection enables coordinated response to short-circuit conditions, and instantaneous protection provides rapid interruption of severe faults.

Typical Applications

  • Main low-voltage switchboards and power distribution boards.
  • Industrial high-current power distribution systems.
  • Transformer secondary and main incomer protection.
  • Large feeder circuits requiring selective protection.
  • Manufacturing and process plant electrical systems.
  • Commercial buildings, utilities and infrastructure installations.

Technical Specifications

Series SACE Emax E4
ABB order code 1SDA056804R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Frame / performance class E4S 4000
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational current (Ie) 4000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Current type AC
Execution Withdrawable moving part (W MP)
Protection release PR122/P-LSI R4000 electronic overcurrent release
Protection functions L (long-time), S (short-time) and I (instantaneous)
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 400/415 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 75 kA
Rated short-time withstand current (Icw), 1 s 75 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Power loss 660 W
Electrical durability at Ue ≤ 440 V 5000 cycles
Electrical durability at Ue 500–690 V 4000 cycles
Mechanical durability 15000 cycles
Auxiliary contacts 4
Position indication Open / closed breaker indication
Standard IEC
Dimensions (W × H × D) 594 × 461 × 396.5 mm
Net weight 85 kg
EAN 8015644581442
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB E4S4000PR122/P-LSI used for?

This ABB SACE Emax air circuit breaker moving part is designed for switching and protecting high-current low-voltage distribution circuits in industrial, commercial and infrastructure electrical systems.

What is the rated current of ABB 1SDA056804R1?

The ABB 1SDA056804R1 has a rated current of 4000 A and uses a three-pole E4S withdrawable air circuit breaker configuration.

What protection release is fitted to this breaker?

The breaker is fitted with an ABB PR122/P-LSI R4000 electronic overcurrent release, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the short-circuit breaking capacity?

The E4S 4000 configuration provides an ultimate short-circuit breaking capacity of 75 kA at 400/415 V AC and maintains a 75 kA rating at 690 V AC.

Is the ABB E4S4000PR122/P-LSI a withdrawable breaker?

Yes. ABB order code 1SDA056804R1 is the withdrawable moving part of the E4S 4000 A three-pole air circuit breaker and is designed for use with the corresponding fixed part.

Trusted for Critical Power Distribution

ABB SACE Emax air circuit breakers are engineered for dependable protection, switching and control of demanding low-voltage electrical distribution systems, combining high-current capability, robust short-circuit performance and advanced electronic protection technology.