1SDA056795R1 ABB E4S4000 PR122/P-LI 4000A 4P Air Circuit Breaker

1SDA056795R1 ABB E4S4000 PR122/P-LI 4000A 4P Air Circuit Breaker

ABB 1SDA056795R1 E4S4000 PR122/P-LI is a 4000 A four-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR122/P-LI R4000 electronic release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056795R1MPN: 1SDA056795R1
Price
List Price £37,881.57 ex VAT
Your Price (ex VAT) Save 25%
£28,411.18 25% OFF
You save £9,470.39 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28,411.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£28,411.18

Why Choose the ABB E4S4000 PR122/P-LI 4000A 4P Air Circuit Breaker?

The ABB E4S4000 PR122/P-LI, order code 1SDA056795R1, is a high-performance SACE Emax E4S air circuit breaker designed for protection and switching in high-current low-voltage electrical distribution systems. Rated at 4000 A, this four-pole fixed circuit breaker combines the robust ABB SACE Emax platform with a PR122/P-LI R4000 electronic overcurrent release.

The PR122/P-LI release provides long-time (L) and instantaneous (I) overcurrent protection, helping protect electrical installations against sustained overloads and severe short-circuit conditions. The advanced electronic release and E4S performance level make this breaker suitable for main distribution switchboards, industrial power systems and other high-capacity installations requiring dependable circuit protection.

This configuration is supplied as a four-pole fixed circuit breaker with rear horizontal terminals. It has a rated operational voltage of 690 V AC and a rated ultimate short-circuit breaking capacity of 75 kA across its specified AC voltage range, providing robust performance for demanding industrial, commercial and infrastructure distribution systems.

Key Advantages

  • High-current 4000 A SACE Emax E4S air circuit breaker for demanding low-voltage distribution.
  • Four-pole configuration provides switching and protection across four conductors.
  • PR122/P-LI electronic overcurrent release provides long-time and instantaneous protection functions.
  • Fixed construction for permanent integration into high-capacity electrical switchboards.
  • Rear horizontal terminals provide a practical connection arrangement for switchboard busbars.
  • 75 kA ultimate and service short-circuit breaking capacity across the specified AC voltage range.
  • 75 kA short-time withstand current for 1 s and 3 s supports robust system coordination.
  • Four auxiliary contacts provide useful circuit-breaker open/closed status signalling.

Key Features

  • ABB SACE Emax E4S series.
  • 4000 A rated current.
  • Four-pole circuit-breaker configuration.
  • PR122/P-LI R4000 electronic overcurrent release.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • Fixed circuit-breaker execution.
  • Rear horizontal main terminals.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary contacts with open/closed position indication.

Reliable 4000A Protection for High-Capacity Electrical Distribution

Air circuit breakers such as the ABB SACE Emax E4S protect high-capacity low-voltage distribution systems against damaging overcurrent conditions. The PR122/P-LI electronic release provides long-time overload and instantaneous short-circuit protection, helping safeguard busbars, feeders and connected electrical equipment while maintaining dependable system operation.

The E4S4000 PR122/P-LI combines a substantial 4000 A current rating, four-pole construction and fixed rear-connected design with 75 kA short-circuit performance. These characteristics make it particularly suitable for main switchboards and other high-capacity distribution assemblies where reliable fault interruption and electronic overcurrent protection are essential.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • High-capacity industrial power distribution systems.
  • Main incoming and high-current feeder protection.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Transformer and generator distribution systems.
  • High-current busbar and distribution-board protection.
  • Electrical installations requiring four-pole switching and overcurrent protection.

Technical Specifications

Series SACE Emax E4S
ABB order code 1SDA056795R1
Product group 310513-New Emax
Product type Air circuit breaker
Rated current (In) 4000 A
Rated operational current (Ie) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Execution Fixed
Main terminal arrangement Rear horizontal
Protection release PR122/P-LI R4000
Release type Electronic
Protection functions Long-time (L) and instantaneous (I)
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 75 kA
Rated short-time withstand current (Icw), 1 s 75 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Short-circuit performance level S
Mechanical endurance 15000 cycles
Electrical endurance at ≤440 V AC 5000 cycles
Electrical endurance at 500–690 V AC 4000 cycles
Power loss 360 W
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Weight 111 kg
Standard IEC
EAN 8015644581350
HS code 85362090

Frequently Asked Questions

What is the ABB 1SDA056795R1?

The ABB 1SDA056795R1 is an E4S4000 SACE Emax air circuit breaker rated at 4000 A, with four poles, fixed construction, rear horizontal terminals and a PR122/P-LI R4000 electronic overcurrent release.

What is the rated current of the E4S4000 PR122/P-LI?

The ABB E4S4000 PR122/P-LI 1SDA056795R1 has a rated operational and uninterrupted current of 4000 A.

What protection functions does the PR122/P-LI release provide?

The PR122/P-LI electronic release provides long-time overload protection (L) and instantaneous short-circuit protection (I).

Is ABB 1SDA056795R1 fixed or withdrawable?

ABB 1SDA056795R1 is a fixed four-pole air circuit breaker equipped with rear horizontal main terminals.

What is the rated operational voltage of ABB 1SDA056795R1?

The E4S4000 PR122/P-LI has a rated operational voltage of 690 V AC, with a rated insulation voltage of 1000 V and rated impulse withstand voltage of 12 kV.

What is the short-circuit breaking capacity of ABB 1SDA056795R1?

The E4S4000 provides a rated ultimate and service short-circuit breaking capacity of 75 kA across its specified AC operating-voltage range.

Trusted by Electrical Engineers Worldwide

ABB SACE Emax air circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable high-current switching, electronic overcurrent protection and robust low-voltage switchgear performance are required.