1SDA056715R1 ABB E3V3200 PR122/P-LI 3200 A 4-Pole Air Circuit Breaker

1SDA056715R1 ABB E3V3200 PR122/P-LI 3200 A 4-Pole Air Circuit Breaker

ABB 1SDA056715R1 E3V3200 is a 3200 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LI electronic trip unit for high-current low-voltage power distribution protection.

SKU: 1SDA056715R1MPN: 1SDA056715R1
Price
List Price £50,125.66 ex VAT
Your Price (ex VAT) Save 25%
£37,594.25 25% OFF
You save £12,531.42 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £37,594.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£37,594.25

Why Choose the ABB E3V3200 PR122/P-LI Air Circuit Breaker?

The ABB 1SDA056715R1 is a high-performance SACE Emax E3V air circuit breaker moving part designed for switching and protection in high-current low-voltage electrical distribution systems. Identified as E3V3200PR122/P-LI, this four-pole withdrawable circuit breaker combines a 3200 A rated current with ABB's advanced PR122/P-LI electronic overcurrent release.

As part of the ABB SACE Emax / New Emax range, the E3V3200 is engineered for demanding industrial, commercial and infrastructure power distribution applications. Its V performance level provides an ultimate short-circuit breaking capacity of 130 kA at 400 V AC, while the withdrawable construction allows the breaker moving part to be disconnected from its fixed section for convenient inspection and maintenance.

The integrated PR122/P-LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. With a rated operational voltage of up to 690 V AC, four-pole configuration and 3200 A rated uninterrupted current, the 1SDA056715R1 is well suited to main incoming, distribution and high-current protection duties in substantial low-voltage installations.

Key Advantages

  • High-capacity 3200 A air circuit breaker for low-voltage power distribution.
  • Four-pole configuration for switching and protection across four conductors.
  • PR122/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • High 130 kA Icu at 400 V AC ultimate short-circuit breaking capacity.
  • Withdrawable construction supports convenient inspection and maintenance.
  • Rated for operation at voltages up to 690 V AC.
  • Four auxiliary contacts and open/closed circuit breaker position indication.
  • Part of ABB's proven SACE Emax circuit breaker range for demanding power distribution applications.

Key Features

  • ABB SACE Emax E3V series.
  • 3200 A rated operational and uninterrupted current.
  • Four-pole circuit breaker configuration.
  • PR122/P-LI electronic overcurrent release.
  • Long-time overload and instantaneous short-circuit protection functions.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 130 kA Icu at 400 V AC.
  • 100 kA Ics at 400 V AC.
  • 85 kA short-time withstand current for 1 s.
  • Withdrawable circuit breaker moving-part design.
  • Fitted with four auxiliary contacts and open/closed position indication.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E3V3200 provide switching and protection for high-current low-voltage distribution systems. The circuit breaker interrupts abnormal current conditions to help protect cables, busbars, switchgear and connected equipment against damage caused by overloads and short circuits.

The PR122/P-LI electronic release provides configurable long-time overload and instantaneous short-circuit protection. Combined with the E3V's high short-circuit performance and withdrawable construction, this makes the 1SDA056715R1 suitable for distribution boards, switchboards and industrial installations where dependable electrical protection and straightforward maintenance are required.

Typical Applications

  • Main incoming circuit protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • Large commercial and infrastructure electrical installations.
  • Protection of distribution feeders and busbar systems.
  • Manufacturing plants and process facilities.
  • Generator and transformer secondary distribution systems.
  • High-current switchgear and electrical distribution installations.

Technical Specifications

Series SACE Emax / New Emax
Product group 310513-New Emax
ABB order code 1SDA056715R1
Product type Air circuit breaker moving part
Frame / performance level E3V
Rated current (In) 3200 A
Rated operational current (Ie) 3200 A
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Trip unit PR122/P-LI
Trip unit type Electronic
Protection functions L and I
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 130 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 85 kA
Short-time withstand current (Icw), 1 s 85 kA
Short-time withstand current (Icw), 3 s 65 kA
Installation type Withdrawable
Auxiliary contacts 4
Position indication Open / closed
Mechanical endurance 20,000 operations
Electrical endurance at ≤440 V AC 6,000 operations
Electrical endurance at 500–690 V AC 5,000 operations
Dimensions (H × W × D) 461 × 558 × 396.5 mm
Net weight 81 kg
Standard IEC
EAN 8015644580551

Frequently Asked Questions

What is the ABB 1SDA056715R1 used for?

The ABB 1SDA056715R1 is a 3200 A four-pole air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution systems.

What trip unit is fitted to the ABB E3V3200?

This version is fitted with the ABB PR122/P-LI electronic trip unit, providing long-time overload and instantaneous short-circuit protection.

What is the rated current of the 1SDA056715R1?

The circuit breaker has a rated current of 3200 A.

What is the breaking capacity of the ABB E3V3200?

The E3V performance version has an ultimate short-circuit breaking capacity (Icu) of 130 kA at 400 V AC and a service short-circuit breaking capacity (Ics) of 100 kA at 400 V AC.

Is the ABB 1SDA056715R1 a withdrawable circuit breaker?

Yes. The 1SDA056715R1 is a withdrawable SACE Emax circuit breaker moving part, allowing it to be disconnected from the corresponding fixed section for inspection, servicing and maintenance.

Trusted ABB Power Distribution Protection

ABB SACE Emax air circuit breakers are engineered for demanding low-voltage power distribution applications, combining high breaking performance, electronic protection and serviceable withdrawable construction for dependable electrical system protection.