ABB 1SDA056432R1 E3H 2000 three-pole fixed air circuit breaker rated at 2000 A with rear horizontal flat terminals and a PR121/P-LI R2000 electronic trip unit providing overload and instantaneous short-circuit protection for demanding low-voltage power distribution.
£12,522.47
The ABB 1SDA056432R1 is a high-performance SACE Emax E3H air circuit breaker designed for switching and protection in demanding low-voltage power distribution systems. Rated at 2000 A, this three-pole fixed circuit breaker incorporates an ABB PR121/P-LI R2000 electronic overcurrent release, providing dependable overload and instantaneous short-circuit protection.
Part of the ABB SACE Emax E3 series, the E3H 2000 combines a 2000 A continuous current rating with high short-circuit interruption capability. It provides a rated ultimate short-circuit breaking capacity of 100 kA at 400 V AC and a rated service short-circuit breaking capacity of 85 kA at 400 V AC, making it suitable for installations with substantial prospective fault currents.
The PR121/P-LI release provides long-time overload (L) and instantaneous short-circuit (I) protection. This version uses a three-pole fixed configuration with rear horizontal flat terminals and is fitted with four change-over auxiliary contacts plus circuit-breaker open/closed position indication for integration into low-voltage switchboards.
Air circuit breakers such as the ABB E3H 2000 provide switching, isolation and automatic protection for important low-voltage distribution circuits. The PR121/P electronic release monitors circuit current and commands the breaker to open when configured overload or instantaneous short-circuit thresholds are exceeded, helping protect conductors, busbars, switchgear and connected equipment.
The combination of LI electronic protection, 100 kA Icu at 400 V AC and 75 kA short-time withstand capability for 1 s makes the 1SDA056432R1 suitable for demanding high-current distribution. Its fixed construction and rear horizontal flat terminals provide a robust arrangement for permanent installation within compatible low-voltage switchboards.
| Series | SACE Emax E3 |
|---|---|
| ABB order code | 1SDA056432R1 |
| Product type | Air circuit breaker |
| Frame | E3 |
| Short-circuit performance level | H |
| Rated current (In) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated operational current (Ie) | 2000 A |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | PR121/P-LI R2000 |
| Release type | Electronic |
| Protection functions | LI – long-time overload and instantaneous short-circuit |
| Overload release adjustment range | 800–2000 A |
| Instantaneous short-circuit release adjustment range | 3000–30,000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 400 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 75 kA |
| Rated short-time withstand current (Icw), 3 s | 65 kA |
| Power loss | 130 W |
| Installation | Fixed |
| Terminal connection | Rear flat horizontal |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Open / closed |
| Motor operator | Optional |
| Electrical durability at ≤440 V | 9000 cycles |
| Electrical durability at 500–690 V | 9000 cycles |
| Mechanical durability | 20,000 cycles |
| Dimensions (W × H × D) | 404 × 418 × 302 mm |
| Net weight | 60 kg |
| Standard | IEC |
| EAN | 8015644577728 |
| Customs tariff number | 85362090 |
| Product group | 310513-New Emax |
The ABB 1SDA056432R1 is a SACE Emax E3H 2000 three-pole fixed air circuit breaker rated at 2000 A and equipped with a PR121/P-LI R2000 electronic overcurrent release.
The PR121/P-LI provides long-time overload (L) and instantaneous short-circuit (I) protection functions.
The circuit breaker has a rated uninterrupted current of 2000 A, with adjustable overload protection from 800–2000 A.
At 400 V AC, the E3H 2000 has a rated ultimate short-circuit breaking capacity of 100 kA and a rated service short-circuit breaking capacity of 85 kA.
The 1SDA056432R1 is a three-pole fixed air circuit breaker with rear horizontal flat terminals, designed for permanent installation within compatible low-voltage switchboards.
ABB SACE Emax air circuit breakers combine electronic overcurrent protection, high short-circuit interruption capability and robust switchboard integration for demanding low-voltage power distribution systems.