1SDA056317R1 ABB E3S 3200 PR122/P-LSIG 3200A 4P Fixed Air Circuit Breaker

1SDA056317R1 ABB E3S 3200 PR122/P-LSIG 3200A 4P Fixed Air Circuit Breaker

ABB 1SDA056317R1 E3S 3200 four-pole fixed air circuit breaker rated at 3200 A with rear horizontal terminals and a PR122/P-LSIG electronic trip unit providing comprehensive LSIG protection for high-current low-voltage power distribution.

SKU: 1SDA056317R1MPN: 1SDA056317R1
Price
List Price £31,805.05 ex VAT
Your Price (ex VAT) Save 25%
£23,853.79 25% OFF
You save £7,951.26 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £23,853.79
Trade pricing is personalised to your account

Manufacturer Lead Time

£23,853.79

Why Choose the ABB E3S 3200 PR122/P-LSIG 3200A 4P Fixed Air Circuit Breaker?

The ABB 1SDA056317R1 is a high-performance SACE Emax E3S air circuit breaker designed for switching and protection in demanding high-current low-voltage power distribution systems. Rated at 3200 A, this four-pole fixed circuit breaker incorporates ABB's advanced PR122/P-LSIG electronic overcurrent release for comprehensive protection of industrial, commercial and infrastructure electrical networks.

Part of the proven ABB SACE Emax E3 series, the E3S 3200 combines substantial current-handling capability with strong short-circuit performance. The S performance level provides rated ultimate and service short-circuit breaking capacities of 75 kA across specified AC voltages up to 690 V AC, making the breaker suitable for demanding main distribution and high-fault-level applications.

The PR122/P-LSIG release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. This version features a four-pole fixed configuration with rear horizontal terminals and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication for integration into low-voltage switchboards and power distribution systems.

Key Advantages

  • High-current 3200 A SACE Emax air circuit breaker for demanding power distribution.
  • Four-pole configuration for comprehensive switching and protection.
  • Advanced PR122/P-LSIG electronic trip unit with overload, short-circuit and earth-fault protection.
  • 75 kA ultimate and service short-circuit breaking capacity at 400 V AC.
  • Suitable for AC distribution systems with operational voltages up to 690 V AC.
  • Fixed construction with rear horizontal terminals for permanent switchboard installation.
  • Four auxiliary contacts and open/closed position indication support monitoring and control.

Key Features

  • ABB SACE Emax E3S 3200 air circuit breaker.
  • 3200 A rated uninterrupted current.
  • Four-pole configuration.
  • PR122/P-LSIG electronic overcurrent release.
  • LSIG protection: long-time, short-time, instantaneous and earth-fault functions.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 75 kA rated ultimate short-circuit breaking capacity across specified AC voltages up to 690 V.
  • 75 kA rated service short-circuit breaking capacity across specified AC voltages up to 690 V.
  • 75 kA short-time withstand current for 1 s.
  • Fixed construction with rear horizontal terminal connections.

Advanced LSIG Protection for High-Current Distribution

Air circuit breakers such as the ABB E3S 3200 provide switching, isolation and automatic protection for high-current low-voltage distribution circuits. The electronic release monitors circuit conditions and commands the breaker to open when configured overload, short-circuit or earth-fault thresholds are reached, helping protect conductors, switchgear and connected electrical equipment.

The PR122/P-LSIG release combines long-time, short-time, instantaneous and earth-fault protection functions for comprehensive protection and coordination within complex electrical networks. Together with the E3S breaker's 75 kA short-circuit performance and fixed rear-terminal arrangement, the 1SDA056317R1 is well suited to critical switchboards requiring dependable high-current protection.

Typical Applications

  • Main incoming protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current feeder and distribution circuits.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure power distribution.
  • Transformer and generator distribution switchboards.
  • Critical installations requiring comprehensive LSIG electronic protection.

Technical Specifications

Series SACE Emax E3
ABB order code 1SDA056317R1
Product type Air circuit breaker
Frame E3
Short-circuit performance level S
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Rated operational current (Ie) 3200 A
Number of poles 4
Current type AC
Trip unit PR122/P-LSIG
Release type Electronic
Protection functions LSIG – long-time, short-time, instantaneous and earth-fault
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 75 kA
Rated service short-circuit breaking capacity (Ics) at 400 V AC 75 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 75 kA
Rated service short-circuit breaking capacity (Ics) at 690 V AC 75 kA
Rated short-time withstand current (Icw), 1 s 75 kA
Rated short-time withstand current (Icw), 3 s 65 kA
Power loss 330 W
Installation Fixed
Terminal connection Rear horizontal
Auxiliary contacts 4
Position indication Open / closed
Electrical durability at ≤440 V 6000 cycles
Electrical durability at 500–690 V 5000 cycles
Mechanical durability 20,000 cycles
Weight 90 kg
EAN 8015644576578
Product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA056317R1?

The ABB 1SDA056317R1 is a SACE Emax E3S 3200 four-pole fixed air circuit breaker rated at 3200 A and equipped with a PR122/P-LSIG electronic overcurrent release.

What protection functions does the PR122/P-LSIG provide?

The PR122/P-LSIG provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection functions.

What is the current rating of the ABB E3S 3200 1SDA056317R1?

The circuit breaker has a rated current and rated uninterrupted current of 3200 A.

What is the breaking capacity of the ABB E3S 3200?

The E3S 3200 has rated ultimate and service short-circuit breaking capacities of 75 kA at 400 V AC, with the E3S performance level maintaining 75 kA at specified AC voltages up to 690 V.

What installation and terminal arrangement does the ABB 1SDA056317R1 use?

The 1SDA056317R1 is a fixed four-pole circuit breaker with rear horizontal terminals, designed for permanent installation within compatible low-voltage switchboards.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax air circuit breakers provide dependable high-current switching and protection for demanding low-voltage power distribution systems, combining advanced electronic protection, high short-circuit performance and robust switchboard construction.