Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056105R1 SACE Emax E2L1600 four-pole withdrawable air circuit breaker moving part with a 1600 A rating, PR121/P-LSI electronic protection and 130 kA breaking capacity at 415 V AC for demanding low-voltage power distribution.
£13,557.65
The ABB 1SDA056105R1 is a high-performance SACE Emax E2L air circuit breaker (ACB) moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the ABB New Emax product group, this four-pole withdrawable circuit breaker combines a 1600 A rated uninterrupted current with the PR121/P-LSI R1600 electronic overcurrent release for dependable protection of industrial, commercial and infrastructure power networks.
The E2L1600 provides long-time, short-time and instantaneous protection through its LSI trip functionality. The PR121/P electronic release protects against overload and short-circuit conditions while providing adjustable protection characteristics that support coordination and selectivity with other protective devices throughout the electrical distribution system.
With a rated uninterrupted current of 1600 A, a 690 V AC rated operational voltage and an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, the E2L1600 is particularly suitable for networks with substantial prospective fault currents. This version is a four-pole withdrawable moving part, allowing removal from a compatible ABB SACE Emax fixed part for inspection, testing, servicing or replacement.
Air circuit breakers such as the ABB SACE Emax E2L1600 provide switching, isolation and overcurrent protection at critical points within high-current low-voltage distribution systems. The E2L performance level provides exceptionally high short-circuit interruption capability, making it suitable for switchboards supplied by large transformers, generators and other sources capable of producing substantial prospective fault currents.
The PR121/P-LSI electronic trip unit provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. Combined with the withdrawable Emax construction, this provides dependable electrical protection while allowing the circuit-breaker moving part to be removed from compatible switchgear for inspection, testing, maintenance or replacement.
| Series | SACE Emax |
|---|---|
| Product group | 310513-New Emax |
| ABB order code | 1SDA056105R1 |
| EAN | 8015644574451 |
| Customs tariff number | 85362090 |
| Product type | Air circuit breaker moving part |
| Frame / size | E2 |
| Short-circuit performance level | L |
| Rated current (In) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Current type | AC |
| Number of poles | 4 |
| Version | Withdrawable moving part (W MP) |
| Trip unit | PR121/P-LSI R1600 |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload release adjustment range | 640–1600 A |
| Short-time delayed short-circuit release adjustment range | 1600–16000 A |
| Instantaneous short-circuit release adjustment range | 2400–24000 A |
| Rated operational voltage | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–415 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 110 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–415 V AC | 130 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 110 kA |
| Rated service short-circuit breaking capacity (Ics) at 500–690 V AC | 65 kA |
| Rated short-time withstand current (Icw), 1 s | 10 kA |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open/closed |
| Mechanical durability | 20,000 operating cycles |
| Maximum mechanical operating frequency | 60 cycles per hour |
| Electrical durability at ≤440 V | 3,000 operating cycles |
| Electrical durability at 500–690 V | 2,000 operating cycles |
| Maximum electrical operating frequency | 20 cycles per hour |
| Power loss | 265 W |
| Dimensions (W × H × D) | 414 × 461 × 396.5 mm |
| Net weight | 61 kg |
| Standard | IEC |
The ABB 1SDA056105R1 is an E2L1600 withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution systems against overload and short-circuit conditions.
This circuit breaker has a rated uninterrupted current of 1600 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.
The PR121/P-LSI electronic overcurrent release provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. This LSI version does not include integrated earth-fault protection.
The E2L1600 has a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC, 110 kA at 440 V AC and 85 kA at 500–690 V AC.
The 1SDA056105R1 is a four-pole withdrawable circuit breaker moving part designed for use with a compatible ABB SACE Emax fixed part, allowing removal for inspection, testing, servicing or replacement.
ABB SACE Emax air circuit breakers provide dependable switching and protection for demanding low-voltage power distribution systems, combining high short-circuit performance with electronic overcurrent protection and service-friendly withdrawable construction.
We use cookies