1SDA056105R1 ABB E2L1600 PR121/P-LSI 1600A 4P Withdrawable Air Circuit Breaker

1SDA056105R1 ABB E2L1600 PR121/P-LSI 1600A 4P Withdrawable Air Circuit Breaker

ABB 1SDA056105R1 SACE Emax E2L1600 four-pole withdrawable air circuit breaker moving part with a 1600 A rating, PR121/P-LSI electronic protection and 130 kA breaking capacity at 415 V AC for demanding low-voltage power distribution.

SKU: 1SDA056105R1MPN: 1SDA056105R1
Price
List Price £18,076.86 ex VAT
Your Price (ex VAT) Save 25%
£13,557.65 25% OFF
You save £4,519.22 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,557.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,557.65

Why Choose the ABB E2L1600 PR121/P-LSI 1600A 4P Withdrawable Air Circuit Breaker?

The ABB 1SDA056105R1 is a high-performance SACE Emax E2L air circuit breaker (ACB) moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the ABB New Emax product group, this four-pole withdrawable circuit breaker combines a 1600 A rated uninterrupted current with the PR121/P-LSI R1600 electronic overcurrent release for dependable protection of industrial, commercial and infrastructure power networks.

The E2L1600 provides long-time, short-time and instantaneous protection through its LSI trip functionality. The PR121/P electronic release protects against overload and short-circuit conditions while providing adjustable protection characteristics that support coordination and selectivity with other protective devices throughout the electrical distribution system.

With a rated uninterrupted current of 1600 A, a 690 V AC rated operational voltage and an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, the E2L1600 is particularly suitable for networks with substantial prospective fault currents. This version is a four-pole withdrawable moving part, allowing removal from a compatible ABB SACE Emax fixed part for inspection, testing, servicing or replacement.

Key Advantages

  • High-performance ABB SACE Emax air circuit breaker moving part for demanding low-voltage distribution.
  • 1600 A rated uninterrupted current for high-current electrical installations.
  • Four-pole withdrawable configuration suitable for three-phase systems requiring neutral switching.
  • Advanced PR121/P-LSI R1600 electronic overcurrent release.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • Exceptional 130 kA Icu and Ics at 415 V AC.
  • 85 kA Icu at 690 V AC for demanding higher-voltage low-voltage networks.
  • Withdrawable construction facilitates inspection, testing, maintenance and replacement within compatible switchgear.

Key Features

  • ABB SACE Emax E2L1600 air circuit breaker moving part.
  • 1600 A rated uninterrupted current.
  • Four-pole construction.
  • Withdrawable circuit-breaker configuration.
  • PR121/P-LSI R1600 electronic overcurrent release.
  • Long-time, short-time and instantaneous (LSI) protection functions.
  • 690 V AC rated operational voltage.
  • 130 kA Icu at 220–415 V AC.
  • 110 kA Icu at 440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.

Reliable High-Capacity Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E2L1600 provide switching, isolation and overcurrent protection at critical points within high-current low-voltage distribution systems. The E2L performance level provides exceptionally high short-circuit interruption capability, making it suitable for switchboards supplied by large transformers, generators and other sources capable of producing substantial prospective fault currents.

The PR121/P-LSI electronic trip unit provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. Combined with the withdrawable Emax construction, this provides dependable electrical protection while allowing the circuit-breaker moving part to be removed from compatible switchgear for inspection, testing, maintenance or replacement.

Typical Applications

  • Main incoming circuit breakers in low-voltage switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and process plants.
  • Transformer-fed distribution systems.
  • Generator distribution and protection systems.
  • High-fault-level electrical networks.
  • Four-pole distribution systems requiring neutral switching.
  • Withdrawable power distribution and switchgear assemblies.

Technical Specifications

Series SACE Emax
Product group 310513-New Emax
ABB order code 1SDA056105R1
EAN 8015644574451
Customs tariff number 85362090
Product type Air circuit breaker moving part
Frame / size E2
Short-circuit performance level L
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated operational current (Ie) 1600 A
Current type AC
Number of poles 4
Version Withdrawable moving part (W MP)
Trip unit PR121/P-LSI R1600
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Overload release adjustment range 640–1600 A
Short-time delayed short-circuit release adjustment range 1600–16000 A
Instantaneous short-circuit release adjustment range 2400–24000 A
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 220–415 V AC 130 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 110 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) at 220–415 V AC 130 kA
Rated service short-circuit breaking capacity (Ics) at 440 V AC 110 kA
Rated service short-circuit breaking capacity (Ics) at 500–690 V AC 65 kA
Rated short-time withstand current (Icw), 1 s 10 kA
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open/closed
Mechanical durability 20,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Electrical durability at ≤440 V 3,000 operating cycles
Electrical durability at 500–690 V 2,000 operating cycles
Maximum electrical operating frequency 20 cycles per hour
Power loss 265 W
Dimensions (W × H × D) 414 × 461 × 396.5 mm
Net weight 61 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056105R1 used for?

The ABB 1SDA056105R1 is an E2L1600 withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution systems against overload and short-circuit conditions.

What is the rated current of the ABB E2L1600 1SDA056105R1?

This circuit breaker has a rated uninterrupted current of 1600 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.

What protection does the PR121/P-LSI trip unit provide?

The PR121/P-LSI electronic overcurrent release provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. This LSI version does not include integrated earth-fault protection.

What is the breaking capacity of the ABB E2L1600?

The E2L1600 has a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC, 110 kA at 440 V AC and 85 kA at 500–690 V AC.

Is the ABB 1SDA056105R1 fixed or withdrawable?

The 1SDA056105R1 is a four-pole withdrawable circuit breaker moving part designed for use with a compatible ABB SACE Emax fixed part, allowing removal for inspection, testing, servicing or replacement.

Trusted Protection from ABB

ABB SACE Emax air circuit breakers provide dependable switching and protection for demanding low-voltage power distribution systems, combining high short-circuit performance with electronic overcurrent protection and service-friendly withdrawable construction.