ABB 1SDA055900R1 E2N1600 is a 1600 A four-pole fixed SACE Emax air circuit breaker with PR122/P-LSI electronic protection, rear horizontal terminals and 65 kA breaking capacity at 400 V AC.
£10,928.51
The ABB 1SDA055900R1 is a high-performance SACE Emax E2N air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. Rated at 1600 A, this four-pole fixed circuit breaker is equipped with the PR122/P-LSI R1600 electronic overcurrent release for comprehensive overload and short-circuit protection.
As part of the ABB SACE Emax / New Emax range, the E2N1600 combines high short-circuit performance with electronic protection for industrial and commercial power distribution. The PR122/P-LSI release provides long-time, short-time and instantaneous protection functions, helping protect cables, busbars, transformers and connected equipment against sustained overloads and short-circuit faults.
The E2N1600 PR122/P-LSI is a four-pole fixed circuit breaker with rear flat horizontal terminals, a rated uninterrupted current of 1600 A and a rated operational voltage of 690 V AC. Its N performance level provides an ultimate and service short-circuit breaking capacity of 65 kA at 400 V AC and 55 kA at 690 V AC, making it suitable for high-fault-level three-phase four-wire distribution systems.
Air circuit breakers such as the ABB E2N1600 provide switching, isolation and protection for high-current low-voltage distribution circuits. The four-pole configuration is particularly suitable for three-phase four-wire systems, while the E2N performance level provides substantial short-circuit interruption capability for installations with elevated prospective fault currents.
The PR122/P-LSI electronic release provides long-time protection against sustained overloads, short-time protection to support selective short-circuit coordination and instantaneous protection against severe fault currents. Together with adjustable protection settings and the E2N's high breaking capacity, these functions support dependable protection and coordination throughout demanding electrical distribution networks.
| Series | SACE Emax / New Emax |
|---|---|
| ABB order code | 1SDA055900R1 |
| Product group | 310513-New Emax |
| Product type | Air circuit breaker (ACB) |
| Rated current (In) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Rated operational voltage | 690 V AC |
| Number of poles | 4 |
| Current type | AC |
| Installation | Fixed |
| Main terminals | Rear flat horizontal (HR) |
| Trip unit | PR122/P-LSI R1600 |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload release adjustment | 640–1600 A |
| Short-time short-circuit release adjustment | 960–16000 A |
| Instantaneous short-circuit release adjustment | 2400–24000 A |
| Short-circuit performance level | N |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 400 V AC | 65 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 65 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 55 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 55 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 55 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 55 kA |
| Rated short-time withstand current (Icw) | 55 kA for 1 s; 42 kA for 3 s |
| Protection rating | IP2X |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Trip indication | Yes |
| Motor operating mechanism | Optional |
| Standards | IEC |
| Weight | 68 kg |
| EAN | 8015644572402 |
The ABB 1SDA055900R1 is a 1600 A four-pole fixed SACE Emax air circuit breaker used for switching and protecting high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure installations.
The circuit breaker has a rated uninterrupted current of 1600 A.
The breaker is fitted with an ABB PR122/P-LSI R1600 electronic overcurrent release, providing long-time, short-time and instantaneous protection.
The E2N1600 provides an ultimate and service short-circuit breaking capacity of 65 kA at 400 V AC and 55 kA at 690 V AC, with a short-time withstand current of 55 kA for 1 s.
The 1SDA055900R1 is a four-pole fixed air circuit breaker with rear flat horizontal terminals for permanent integration into compatible low-voltage switchboards.
ABB SACE Emax air circuit breakers are designed for dependable switching and protection in demanding low-voltage power distribution systems, combining high short-circuit performance, adjustable electronic LSI protection and robust switchboard integration.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.