ABB 1SDA055856R1 SACE New Emax E2N1250 three-pole fixed air circuit breaker with 1250 A rated current, PR121/P-LI R1250 electronic protection, rear horizontal terminals and 65 kA Icu at 400 V AC.

SKU: 1SDA055856R1MPN: 1SDA055856R1
Price
List Price £10,128.22 ex VAT
Your Price (ex VAT) Save 25%
£7,596.17 25% OFF
You save £2,532.06 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,596.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,596.17

Why Choose the ABB 1SDA055856R1 E2N1250 Air Circuit Breaker?

The ABB 1SDA055856R1 is a SACE New Emax E2N1250 air circuit breaker (ACB) designed for dependable switching and protection in demanding low-voltage electrical distribution systems. This three-pole fixed circuit breaker has a rated uninterrupted current of 1250 A and is equipped with the ABB PR121/P-LI R1250 electronic overcurrent release.

The PR121/P-LI trip unit provides long-time (L) overload and instantaneous (I) short-circuit protection. Its adjustable protection characteristics help protect conductors, switchgear and connected equipment against damaging overcurrent conditions, making the breaker suitable for industrial, commercial and infrastructure power distribution.

This E2N1250 configuration features a three-pole fixed construction with rear horizontal terminals. It is rated at 690 V AC and provides a rated ultimate short-circuit breaking capacity of 65 kA at 400 V AC, 50 Hz, while four auxiliary contacts and open/closed position indication support integration into switchboard control and monitoring systems.

Key Advantages

  • Genuine ABB SACE New Emax E2N1250 air circuit breaker.
  • 1250 A rated uninterrupted current for high-current low-voltage distribution.
  • Three-pole fixed configuration for three-phase electrical systems.
  • PR121/P-LI R1250 electronic overcurrent release.
  • Provides long-time overload and instantaneous short-circuit protection.
  • 65 kA Icu at 400 V AC, 50 Hz for demanding fault-current applications.
  • Rear horizontal terminals provide a practical connection arrangement for fixed switchgear installations.

Key Features

  • ABB SACE New Emax E2N1250 series.
  • 1250 A rated uninterrupted current.
  • 690 V AC rated voltage.
  • Three-pole fixed construction.
  • PR121/P-LI R1250 electronic trip unit.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 500–1250 A overload release setting range.
  • 1875–18750 A instantaneous short-circuit release adjustment range.
  • 65 kA rated ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • Rear horizontal main circuit terminals.
  • Four auxiliary contacts for status signalling.
  • Open/closed circuit-breaker position indication.
  • Optional motor operating mechanism capability.

High-Performance Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE New Emax E2N1250 provide switching, isolation and overcurrent protection for high-current low-voltage distribution circuits. With a rated ultimate short-circuit breaking capacity of 65 kA at 400 V AC, the E2N performance level is suitable for installations where substantial prospective fault currents must be safely interrupted.

The PR121/P-LI release combines adjustable long-time overload protection with instantaneous short-circuit protection. Together with the 1250 A current rating, fixed three-pole construction and rear horizontal terminals, the 1SDA055856R1 provides a practical solution for permanent installation within industrial switchboards and main low-voltage distribution assemblies.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming circuit protection.
  • High-current feeder protection.
  • Commercial building electrical distribution systems.
  • Manufacturing and process industry power systems.
  • Infrastructure and utility electrical installations.
  • Distribution systems with high prospective short-circuit currents.

Technical Specifications

Series SACE New Emax E2N
Extended product type E2N1250PR121/P-LIIn=1250A3pFHR
Order code / MPN 1SDA055856R1
ABB product group 310513-New Emax
Product type Air circuit breaker (ACB)
Breaker frame E2N1250
Rated uninterrupted current (Iu) 1250 A
Rated voltage 690 V AC
Current type AC
Number of poles 3
Trip unit PR121/P-LI R1250
Release technology Electronic
Protection functions L (long-time) and I (instantaneous)
Overload release setting range 500–1250 A
Instantaneous short-circuit release adjustment range 1875–18750 A
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 65 kA
Construction Fixed
Main terminals Rear horizontal
Auxiliary contacts 4
Open/closed position indication Yes
Motor operating mechanism Optional
Mechanical durability 25,000 cycles
Electrical durability 15,000 cycles
Dimensions (W × H × D) 296 × 418 × 302 mm
Net weight 45 kg
EAN 8015644571962
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA055856R1 used for?

The ABB 1SDA055856R1 is a 1250 A three-pole fixed air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution circuits.

What protection functions does the ABB 1SDA055856R1 provide?

The fitted PR121/P-LI R1250 electronic trip unit provides long-time overload and instantaneous short-circuit protection.

What is the breaking capacity of the ABB 1SDA055856R1?

The E2N1250 has a rated ultimate short-circuit breaking capacity of 65 kA at 400 V AC, 50 Hz.

Is the ABB 1SDA055856R1 fixed or withdrawable?

The 1SDA055856R1 is a fixed three-pole air circuit breaker equipped with rear horizontal terminals for permanent installation within compatible low-voltage switchgear.

What are the protection adjustment ranges of the ABB 1SDA055856R1?

The PR121/P-LI configuration provides an overload release setting range of 500–1250 A and an instantaneous short-circuit release adjustment range of 1875–18750 A.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage power distribution systems, combining high-current capability, electronic overcurrent protection and robust switchgear integration.