ABB 1SDA055804R1 SACE Emax E2B 1600 is a 1600 A four-pole fixed air circuit breaker with a PR122/P-LSI electronic release, rear horizontal terminals and 42 kA short-circuit breaking capacity at 415 V AC.
£10,685.97
The ABB 1SDA055804R1 is a high-performance SACE Emax E2B 1600 air circuit breaker designed for switching and overcurrent protection in low-voltage AC power distribution systems. This four-pole fixed circuit breaker has a rated current of 1600 A and is equipped with an electronic PR122/P-LSI R1600 overcurrent release providing long-time, short-time and instantaneous protection.
Part of the proven ABB SACE Emax range, the E2B 1600 combines high-current switching capability with configurable electronic protection for industrial switchboards and power distribution assemblies. Its B performance level provides rated ultimate and service short-circuit breaking capacities of 42 kA at 415 V AC, with the same 42 kA rating specified across the breaker’s 220–690 V AC operating range.
The 1SDA055804R1 is a four-pole fixed (F) circuit breaker with rear flat horizontal terminals. It has a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V and rated impulse withstand voltage of 12 kV. Four auxiliary contacts and circuit-breaker open/closed position indication are included for integration with switchboard signalling and monitoring systems.
Air circuit breakers such as the ABB SACE Emax E2B 1600 provide switching and overcurrent protection for high-current low-voltage distribution circuits. The PR122/P-LSI electronic release provides long-time protection against sustained overloads, short-time protection for selective fault coordination and instantaneous protection against severe short-circuit currents.
The combination of 1600 A current capacity, four-pole construction, fixed mounting and 42 kA short-circuit performance at 415 V AC makes the 1SDA055804R1 well suited to main incoming and high-current feeder applications. Its rear horizontal terminals and auxiliary signalling contacts also support effective integration into industrial switchboards and power distribution assemblies.
| Series | SACE Emax |
|---|---|
| ABB order code | 1SDA055804R1 |
| Product type | Air circuit breaker |
| Frame / sub-type | E2 |
| Performance level | B |
| Rated current (In) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Number of poles | 4 |
| Current type | AC |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) at 415 V AC | 42 kA |
| Rated short-time withstand current (Icw) | 42 kA for 1 s |
| Release | PR122/P-LSI R1600 |
| Release type | Electronic |
| Protection functions | LSI – long-time, short-time and instantaneous |
| Long-time protection (L) | Overload protection |
| Short-time protection (S) | Selective short-circuit protection |
| Instantaneous protection (I) | Instantaneous short-circuit protection |
| Installation | Fixed |
| Terminal connection | Rear flat horizontal |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 115 W |
| Mechanical durability | 25,000 cycles |
| Electrical durability at ≤440 V | 12,000 cycles |
| Electrical durability at 500–690 V | 10,000 cycles |
| Standard | IEC |
| Weight | 68 kg |
| EAN | 8015644571443 |
The ABB 1SDA055804R1 is a 1600 A four-pole air circuit breaker designed for switching and overcurrent protection in industrial, commercial and infrastructure low-voltage power distribution systems.
The breaker is fitted with a PR122/P-LSI R1600 electronic release providing long-time, short-time and instantaneous overcurrent protection.
LSI denotes long-time, short-time and instantaneous protection, providing protection against sustained overloads and different levels of short-circuit current while supporting selective fault coordination.
The 1SDA055804R1 is a fixed four-pole circuit breaker with rear flat horizontal terminals for permanent installation within a low-voltage switchboard.
The E2B 1600 has rated ultimate and service short-circuit breaking capacities of 42 kA at 415 V AC and a rated short-time withstand current of 42 kA for both 1 s and 3 s.
ABB SACE Emax air circuit breakers provide robust switching and electronic protection for low-voltage power distribution, combining high current capability, configurable protection and dependable short-circuit performance for demanding industrial switchboards and infrastructure.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.