1SDA055666R1 ABB E1B 1600 PR121/P-LSIG 1600 A 3-Pole Fixed Air Circuit Breaker

1SDA055666R1 ABB E1B 1600 PR121/P-LSIG 1600 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA055666R1 E1B 1600 PR121/P-LSIG is a 1600 A three-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR121/P-LSIG R1600 electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection.

SKU: 1SDA055666R1MPN: 1SDA055666R1
Price
List Price £11,793.06 ex VAT
Your Price (ex VAT) Save 25%
£8,844.80 25% OFF
You save £2,948.27 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,844.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,844.80

Why Choose the ABB E1B 1600 PR121/P-LSIG Air Circuit Breaker?

The ABB E1B 1600 PR121/P-LSIG, order code 1SDA055666R1, is a SACE Emax fixed air circuit breaker designed for high-current low-voltage power distribution and protection. This three-pole configuration is rated at 1,600 A and features rear horizontal terminals together with the PR121/P-LSIG R1600 electronic overcurrent release.

The PR121/P-LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. This comprehensive LSIG protection makes the breaker suitable for main distribution, transformer and generator applications where coordinated protection against overloads and multiple fault conditions is required.

The E1B performance level provides rated ultimate and service short-circuit breaking capacities of 42 kA at 400/415 V AC, together with a rated short-time withstand current of 42 kA for 1 s. Four auxiliary contacts and open/closed position indication further support integration into switchboard signalling, monitoring and control systems.

Key Advantages

  • High-current 1,600 A SACE Emax air circuit breaker for demanding distribution systems.
  • PR121/P-LSIG electronic trip unit provides comprehensive LSIG protection.
  • Integrated earth-fault protection complements overload and short-circuit protection.
  • 42 kA Icu and Ics at 400/415 V AC.
  • 42 kA short-time withstand current for 1 s.
  • Fixed three-pole construction with rear horizontal terminals for permanent switchboard installation.
  • Four auxiliary contacts and open/closed indication support status monitoring and control.

Key Features

  • ABB SACE Emax E1B series.
  • 1,600 A rated current.
  • Three-pole configuration.
  • Fixed execution.
  • Rear horizontal terminals.
  • PR121/P-LSIG R1600 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Earth-fault protection.
  • 690 V AC rated operational voltage.
  • 1,000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 42 kA Icu and Ics at 400/415 V AC.
  • 42 kA Icw for 1 s and 36 kA for 3 s.
  • Four auxiliary contacts with open/closed position indication.

Comprehensive LSIG Protection for High-Current Distribution

The ABB SACE Emax E1B combines 1,600 A switching capacity with electronic protection for demanding low-voltage distribution circuits. Its PR121/P-LSIG R1600 release provides long-time, short-time, instantaneous and earth-fault protection, helping safeguard cables, busbars, transformers and downstream equipment against sustained overloads, short circuits and earth faults.

The fixed three-pole construction with rear horizontal terminals is designed for permanent installation in low-voltage switchboards. With a 42 kA breaking capacity at 400/415 V AC and four auxiliary contacts for status signalling, the E1B 1600 is well suited to main distribution and other high-current protection duties where dependable operation and system coordination are required.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Transformer secondary protection.
  • Generator distribution and protection systems.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical installations.
  • High-current feeder and busbar protection.

Technical Specifications

Series SACE Emax E1
ABB order code 1SDA055666R1
Product group 310513-New Emax
Product type Air circuit breaker
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated operational current (Ie) 1600 A
Number of poles 3
Execution Fixed
Terminal connection Rear horizontal
Trip unit PR121/P-LSIG R1600
Release type Electronic
Protection functions L-S-I-G
Long-time overload protection Yes
Short-time short-circuit protection Yes
Instantaneous short-circuit protection Yes
Earth-fault protection Yes
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) at 400/415 V AC 42 kA
Rated short-time withstand current (Icw), 1 s 42 kA
Rated short-time withstand current (Icw), 3 s 36 kA
Short-circuit performance level B
Auxiliary contacts 4
Position indication Open / closed
Power loss 253 W
Standard IEC
EAN 8015644570064
Net weight 50 kg

Frequently Asked Questions

What is the ABB 1SDA055666R1?

The ABB 1SDA055666R1 is an E1B 1600 three-pole fixed SACE Emax air circuit breaker rated at 1,600 A, with rear horizontal terminals and a PR121/P-LSIG R1600 electronic overcurrent release.

What protection does the PR121/P-LSIG trip unit provide?

The PR121/P-LSIG electronic release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB E1B 1600?

The E1B 1600 has rated ultimate and service short-circuit breaking capacities of 42 kA at 400/415 V AC.

Does the ABB 1SDA055666R1 provide earth-fault protection?

Yes. The G function of the PR121/P-LSIG release provides earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.

What type of installation does the ABB 1SDA055666R1 use?

The 1SDA055666R1 is a fixed three-pole circuit breaker with rear horizontal terminals, designed for permanent installation in a compatible low-voltage switchboard or distribution assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax air circuit breakers provide dependable protection and control for low-voltage power distribution systems, combining high-current switching capability, electronic protection and robust construction for demanding industrial, commercial and infrastructure installations.