1SDA054887R1 ABB UVR-C T4-T5-T6 24–30 V AC/DC Undervoltage Release

1SDA054887R1 ABB UVR-C T4-T5-T6 24–30 V AC/DC Undervoltage Release

ABB 1SDA054887R1 UVR-C is a wired 24–30 V AC/DC undervoltage release designed for compatible ABB SACE Tmax T4, T5 and T6 moulded case circuit breakers.

SKU: 1SDA054887R1Alt SKU: T4-5MPN: 1SDA054887R1
Price
List Price £315.85 ex VAT
Your Price (ex VAT) Save 25%
£236.89 25% OFF
You save £78.96 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £236.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£236.89

Why Choose the ABB 1SDA054887R1 UVR-C Undervoltage Release?

The ABB 1SDA054887R1 is a wired UVR-C undervoltage release designed for use with compatible ABB SACE Tmax T4, T5 and T6 moulded case circuit breakers. As part of the ABB Tmax circuit breaker accessory range, it provides automatic circuit breaker opening when the control supply voltage falls below the required operating level.

The UVR-C is designed to enhance electrical protection and control by preventing a compatible circuit breaker from remaining closed when adequate control voltage is unavailable. This makes it particularly useful in industrial distribution systems, machinery and automation applications where controlled disconnection following loss or reduction of supply voltage is required.

With a rated control voltage of 24–30 V AC/DC, the 1SDA054887R1 is suitable for both AC and DC control circuits. Its cabled configuration is designed for ABB SACE Tmax T4, T5 and T6 circuit breakers and supports straightforward integration into compatible switchboards and electrical control systems.

Key Advantages

  • Provides undervoltage protection for compatible ABB Tmax circuit breakers.
  • 24–30 V AC/DC rated control voltage supports both AC and DC control systems.
  • Designed specifically for ABB SACE Tmax T4, T5 and T6 circuit breakers.
  • Cabled UVR-C configuration for convenient electrical integration.
  • Supports automatic breaker opening following an unacceptable reduction or loss of control voltage.
  • Suitable for industrial switchboards, machinery, automation and power distribution systems.

Key Features

  • ABB UVR-C wired undervoltage release.
  • 24–30 V AC rated voltage.
  • 24–30 V DC rated voltage.
  • Compatible with Tmax T4, T5 and T6 moulded case circuit breakers.
  • Cabled version for connection within compatible circuit breaker installations.
  • AC/DC current type for flexible control circuit integration.
  • Designed to initiate circuit breaker opening under undervoltage conditions.
  • IEC-compliant ABB circuit breaker accessory.

Reliable Undervoltage Protection for Circuit Breakers

An undervoltage release monitors its control supply and operates the associated circuit breaker when the voltage falls below the level required to maintain normal operation. This provides a controlled means of disconnecting electrical loads following a significant voltage reduction or complete loss of the control supply.

The ABB UVR-C range is engineered for integration with compatible SACE Tmax circuit breakers. The cabled 1SDA054887R1 is designed for T4, T5 and T6 devices and provides a practical solution for industrial installations requiring undervoltage-operated breaker control from a 24–30 V AC/DC supply.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Machinery requiring undervoltage-operated disconnection.
  • Industrial automation and control panels.
  • Motor control and protection systems.
  • Power distribution and electrical protection systems.
  • ABB Tmax T4, T5 and T6 circuit breaker installations requiring a wired undervoltage release.

Technical Specifications

Series SACE Tmax T
Order code 1SDA054887R1
Product type Wired undervoltage release
Accessory type UVR-C
Compatible circuit breakers Tmax T4, T5 and T6
Rated AC voltage 24–30 V AC
Rated DC voltage 24–30 V DC
Current type AC/DC
Configuration Cabled / wired
Standards IEC
Product class Moulded case circuit breaker accessory
Product net weight 0.169 kg
EAN 8015644560157

Frequently Asked Questions

What is the ABB 1SDA054887R1 used for?

The ABB 1SDA054887R1 is a wired undervoltage release designed to operate compatible ABB SACE Tmax T4, T5 and T6 circuit breakers when the control supply voltage falls below the required operating level.

Which ABB circuit breakers are compatible with the 1SDA054887R1?

The UVR-C is designed for use with ABB SACE Tmax T4, T5 and T6 moulded case circuit breakers.

What control voltage does the ABB 1SDA054887R1 use?

The 1SDA054887R1 has a rated control voltage of 24–30 V AC/DC, making it suitable for compatible AC and DC control circuits.

What does UVR-C mean on this ABB accessory?

UVR identifies the accessory as an undervoltage release, while the UVR-C designation identifies the cabled version designed for electrical connection within compatible ABB Tmax circuit breaker installations.

Where is the ABB 1SDA054887R1 typically installed?

It is typically fitted to a compatible ABB Tmax T4, T5 or T6 circuit breaker within an industrial switchboard, distribution panel, machinery control panel or automation system requiring undervoltage-operated circuit breaker control.

Trusted ABB Circuit Breaker Accessories

ABB SACE Tmax circuit breaker accessories provide flexible control and protection functionality for industrial and commercial power distribution systems, with UVR-C undervoltage releases enabling compatible circuit breakers to respond automatically to unacceptable reductions or loss of control voltage.