1SDA054733R1 ABB TMA500-5000 T5 630 500 A 4-Pole Thermomagnetic Trip Unit

1SDA054733R1 ABB TMA500-5000 T5 630 500 A 4-Pole Thermomagnetic Trip Unit

ABB 1SDA054733R1 TMA500-5000 500 A four-pole thermomagnetic trip unit with a fully rated neutral and adjustable magnetic short-circuit protection for compatible ABB Tmax T5 630 circuit breakers.

SKU: 1SDA054733R1MPN: 1SDA054733R1
Price
List Price £1,662.31 ex VAT
Your Price (ex VAT) Save 25%
£1,246.73 25% OFF
You save £415.58 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,246.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,246.73

Why Choose the ABB 1SDA054733R1 TMA500-5000 T5 Trip Unit?

The ABB 1SDA054733R1 is a four-pole TMA thermomagnetic trip unit designed for use with ABB Tmax T5 630 moulded-case circuit breakers. Part of the ABB Tmax T4–T8 circuit-breaker range, this protection release provides dependable thermal overload and magnetic short-circuit protection for industrial low-voltage electrical distribution systems.

The TMA release combines adjustable thermal overload protection with instantaneous magnetic protection against high short-circuit currents. This proven thermomagnetic protection technology operates without requiring an electronic trip system, making it a robust solution for switchboards, distribution panels, industrial machinery and other demanding electrical installations.

With a rated current of 500 A, a four-pole configuration and a fully rated neutral at 100% of phase current, the 1SDA054733R1 is particularly suitable for three-phase four-wire distribution systems. Its TMA500-5000 release provides instantaneous magnetic short-circuit protection adjustable from 2500–5000 A.

Key Advantages

  • Reliable thermomagnetic protection for ABB Tmax T5 630 circuit breakers.
  • 500 A rated current for high-current industrial distribution applications.
  • Four-pole configuration suitable for three-phase four-wire electrical systems.
  • Fully rated neutral at 100% of phase current.
  • Adjustable instantaneous magnetic protection from 2500–5000 A.
  • Combines thermal overload and magnetic short-circuit protection in a proven protection system.

Key Features

  • ABB TMA500-5000 thermomagnetic trip unit.
  • Designed for ABB Tmax T5 630 moulded-case circuit breakers.
  • 500 A rated current.
  • Four-pole (4P) configuration.
  • 100% rated neutral protection.
  • Thermal protection against sustained overload conditions.
  • Adjustable magnetic instantaneous protection from 2500–5000 A.
  • Suitable for industrial low-voltage power distribution applications.

Reliable Thermomagnetic Protection for High-Current Circuits

Thermomagnetic trip units use complementary thermal and magnetic protection mechanisms. The thermal element responds to sustained overcurrent conditions to protect against overloads, while the magnetic element provides rapid tripping when a high short-circuit current exceeds the selected instantaneous threshold.

The ABB TMA500-5000 release provides adjustable instantaneous protection from 2500–5000 A. Combined with its four-pole construction and fully rated neutral, this makes the unit particularly suitable for three-phase four-wire industrial distribution systems where dependable phase and neutral protection is required.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • ABB Tmax T5 630 moulded-case circuit breakers.
  • Three-phase four-wire electrical systems.
  • Electrical switchboards and distribution panels.
  • Industrial machinery and manufacturing installations.
  • High-current feeder circuits requiring overload and short-circuit protection.

Technical Specifications

Product group 310511-T-Max T4 - T8
Order code / MPN 1SDA054733R1
Product type Thermomagnetic trip unit / protection release
Circuit-breaker series ABB Tmax
Compatible circuit breaker Tmax T5 630
Trip unit TMA500-5000
Protection type Thermal overload and magnetic short-circuit protection
Rated current 500 A
Number of poles 4
Neutral rating 100% In
Instantaneous short-circuit setting range 2500–5000 A
Frame rating 630 A
Standards family IEC

Frequently Asked Questions

What is the ABB 1SDA054733R1 used for?

The ABB 1SDA054733R1 is a TMA500-5000 thermomagnetic trip unit designed for compatible ABB Tmax T5 630 circuit breakers, providing thermal overload and magnetic short-circuit protection for low-voltage electrical distribution systems.

What is the rated current of the ABB 1SDA054733R1?

The TMA500-5000 trip unit has a rated current of 500 A and is designed for the Tmax T5 630 frame.

What is the instantaneous short-circuit setting range?

The magnetic instantaneous short-circuit protection is adjustable from 2500–5000 A.

What does InN=100%In mean?

InN=100%In means the neutral is fully rated at 100% of the phase rated current, making the four-pole trip unit suitable for applications where full neutral-current capability is required.

Which circuit breaker is the ABB 1SDA054733R1 designed for?

The 1SDA054733R1 is a four-pole TMA thermomagnetic trip unit designed for compatible ABB Tmax T5 630 moulded-case circuit breakers.

Trusted ABB Circuit Protection

ABB Tmax circuit-breaker protection systems provide dependable low-voltage electrical protection, combining robust moulded-case circuit-breaker technology with thermomagnetic releases for industrial switchboards, distribution systems and machinery installations.