1SDA054679R1 ABB MA160-2240 T4 3p Magnetic Trip Unit

1SDA054679R1 ABB MA160-2240 T4 3p Magnetic Trip Unit

ABB 1SDA054679R1 MA160-2240 three-pole magnetic-only trip unit for compatible SACE Tmax T4 circuit breakers with a 160 A rated current and adjustable instantaneous short-circuit protection from 960–2240 A.

SKU: 1SDA054679R1MPN: 1SDA054679R1
Price
List Price £2,902.85 ex VAT
Your Price (ex VAT) Save 25%
£2,177.14 25% OFF
You save £725.71 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,177.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,177.14

Why Choose the ABB MA160-2240 T4 3p?

The ABB MA160-2240 T4 3p, order code 1SDA054679R1, is a three-pole magnetic-only trip unit designed for compatible ABB SACE Tmax T4 moulded case circuit breakers. With a rated current of 160 A and an adjustable instantaneous trip threshold of 960–2240 A, it provides dedicated short-circuit protection for demanding motor circuits.

The MA magnetic release provides instantaneous magnetic protection without incorporating thermal overload protection. This makes it particularly suitable for motor protection arrangements where overload protection is provided by a separate device, while the Tmax circuit breaker and MA release provide rapid interruption of short-circuit currents.

Designed for three-pole Tmax T4 circuit breaker configurations, the MA160-2240 provides an instantaneous magnetic setting range equivalent to approximately 6–14 × In. Its adjustable threshold helps accommodate normal motor starting currents while allowing the protection system to respond rapidly to severe electrical faults.

Key Advantages

  • Genuine ABB SACE Tmax T4 magnetic-only trip unit.
  • 160 A rated current for compatible Tmax T4 circuit breakers.
  • Adjustable instantaneous magnetic protection from 960–2240 A.
  • Three-pole configuration for three-phase motor circuits.
  • Magnetic-only protection provides rapid response to short-circuit faults.
  • Ideal for motor protection applications where overload protection is provided separately.
  • Adjustable magnetic threshold helps coordinate protection with motor starting characteristics.

Key Features

  • ABB SACE Tmax T4 series.
  • MA160-2240 magnetic-only release.
  • 160 A rated current.
  • Three-pole configuration.
  • Instantaneous magnetic short-circuit protection.
  • 960–2240 A instantaneous trip adjustment range.
  • Magnetic adjustment equivalent to approximately 6–14 × In.
  • Designed for compatible ABB SACE Tmax T4 circuit breakers.
  • Suitable for coordinated motor circuit protection.
  • No thermal overload protection incorporated in the MA release.

Adjustable Magnetic Protection for Motor Circuits

Motor circuits typically require protection against both overloads and short circuits, but these functions can be provided by separate coordinated devices. The ABB MA160-2240 provides the instantaneous short-circuit element, with an adjustable magnetic threshold of 960–2240 A that allows protection to be coordinated with the characteristics of the connected motor.

Because the MA release does not provide thermal overload protection, appropriate separate overload protection should be incorporated where required by the application. This arrangement helps prevent normal motor starting currents from causing unwanted operation while retaining rapid protection against high-current short-circuit faults.

Typical Applications

  • Three-phase motor protection circuits.
  • Industrial motor control centres.
  • Manufacturing machinery and production equipment.
  • Pumps, fans and compressor systems.
  • Conveyor and material handling equipment.
  • HVAC motor circuits.
  • Industrial control panels and switchboards.
  • Replacement or configuration of compatible ABB Tmax T4 circuit breakers.

Technical Specifications

Series SACE Tmax T4
Order code / MPN 1SDA054679R1
Product group Tmax T4 - T8
Product type Magnetic-only trip unit / magnetic release
Trip unit MA
Rated current (In) 160 A
Instantaneous trip current (I3) 960–2240 A
Magnetic adjustment approximately 6–14 × In
Number of poles 3
Protection function Instantaneous magnetic short-circuit protection
Thermal overload protection Not included
Compatible circuit breaker family ABB SACE Tmax T4

Frequently Asked Questions

What is the ABB 1SDA054679R1?

The ABB 1SDA054679R1 is an MA160-2240 three-pole magnetic-only trip unit designed for compatible ABB SACE Tmax T4 moulded case circuit breakers.

What is the rated current of the ABB MA160-2240?

The MA160-2240 trip unit has a rated current of 160 A.

What is the magnetic protection range of the ABB MA160-2240?

The instantaneous magnetic trip current is adjustable from 960–2240 A, corresponding to approximately 6–14 × In.

Does the ABB MA160-2240 provide overload protection?

No. The MA160-2240 provides instantaneous magnetic short-circuit protection and does not incorporate thermal overload protection, so suitable separate overload protection should be used where required.

What circuit breakers are compatible with ABB 1SDA054679R1?

The 1SDA054679R1 is designed for compatible three-pole ABB SACE Tmax T4 moulded case circuit breaker configurations.

Trusted ABB Motor Circuit Protection

ABB SACE Tmax circuit protection components provide flexible solutions for industrial power distribution and motor applications, with MA magnetic-only releases enabling adjustable instantaneous short-circuit protection as part of a coordinated motor protection system.