1SDA054625R1 ABB PR222DS/P-LSIG In=160 T4 4P Electronic Trip Unit

1SDA054625R1 ABB PR222DS/P-LSIG In=160 T4 4P Electronic Trip Unit

ABB PR222DS/P-LSIG In=160 T4 4P electronic trip unit providing LSIG protection for ABB Tmax T4 moulded case circuit breakers.

SKU: 1SDA054625R1MPN: 1SDA054625R1
Price
List Price £2,999.04 ex VAT
Your Price (ex VAT) Save 25%
£2,249.28 25% OFF
You save £749.76 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,249.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,249.28

Why Choose the ABB PR222DS/P-LSIG In=160 T4 4P Electronic Trip Unit?

The ABB PR222DS/P-LSIG In=160 T4 4P is an advanced electronic trip unit designed for ABB Tmax T4 moulded case circuit breakers, providing comprehensive protection and monitoring for low-voltage electrical distribution systems. Part of the ABB Tmax electronic release family, this unit delivers reliable long-time, short-time, instantaneous and earth fault protection functions for industrial and commercial applications.

Engineered for use with compatible ABB Tmax T4 circuit breakers, the PR222DS/P-LSIG combines advanced electronic protection technology with adjustable settings to improve system safety, selectivity and operational reliability. Its integrated protection functions help safeguard cables, motors and electrical equipment against overload, short-circuit and earth fault conditions.

With a rated current setting of 160 A and four-pole Tmax T4 compatibility, the ABB PR222DS/P-LSIG electronic release is suitable for applications requiring comprehensive LSIG protection in modern low-voltage power distribution systems.

Key Advantages

  • Electronic LSIG protection for complete overload, short-circuit and earth fault protection.
  • 160 A rated current setting suitable for industrial and commercial distribution applications.
  • Designed specifically for ABB Tmax T4 moulded case circuit breakers.
  • Adjustable protection parameters improve system flexibility and selectivity.
  • Enhances circuit breaker performance and electrical system reliability.
  • Reliable ABB electronic protection technology for demanding installations.

Key Features

  • ABB PR222DS/P-LSIG electronic trip unit.
  • Compatible with ABB Tmax T4 circuit breakers.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground fault (G) protection.
  • Rated current setting: 160 A.
  • Four-pole Tmax T4 application.
  • Electronic protection release for improved accuracy and reliability.

Reliable Protection for Industrial Power Systems

The ABB PR222DS/P-LSIG electronic trip unit enhances Tmax T4 circuit breaker performance by providing precise electronic protection against overload, short-circuit and earth fault conditions. This helps protect electrical equipment, cables and distribution networks while supporting reliable system operation.

ABB Tmax electronic releases are designed for professional electrical installations, combining advanced protection functionality with straightforward integration into established moulded case circuit breaker platforms.

Typical Applications

  • Industrial switchboards and distribution panels.
  • Electrical protection assemblies.
  • Motor and machinery supply systems.
  • Commercial power distribution equipment.
  • Industrial automation installations.
  • Low-voltage switchgear systems.

Technical Specifications

Series Tmax T4
Order code 1SDA054625R1
Product type Electronic trip unit
Compatible circuit breaker ABB Tmax T4
Rated current setting 160 A
Protection functions Long-time, short-time, instantaneous and ground fault protection
Trip unit type Electronic LSIG release
Number of poles 4 poles
Application Low-voltage AC distribution systems

Frequently Asked Questions

What is the ABB PR222DS/P-LSIG In=160 T4 4P used for?

This electronic trip unit provides long-time, short-time, instantaneous and ground fault protection for compatible ABB Tmax T4 moulded case circuit breakers.

What is the rated current setting of this trip unit?

The ABB PR222DS/P-LSIG In=160 has a rated current setting of 160 A.

Which circuit breaker series is this release compatible with?

The trip unit is designed for use with ABB Tmax T4 moulded case circuit breakers.

What protection functions are included?

The PR222DS/P-LSIG provides long-time, short-time, instantaneous and ground fault protection functions.

How many poles is this application designed for?

This trip unit configuration is intended for four-pole ABB Tmax T4 circuit breaker applications.

Trusted by Industrial Engineers Worldwide

ABB Tmax electronic trip units are widely selected by electrical engineers and system designers for accurate protection, reliable operation and seamless integration with ABB moulded case circuit breakers.