1SDA054614R1 ABB PR222DS/P-LSIG In=250 T4 3p Electronic Trip Unit

1SDA054614R1 ABB PR222DS/P-LSIG In=250 T4 3p Electronic Trip Unit

ABB 1SDA054614R1 PR222DS/P-LSIG is a 250 A three-pole electronic trip unit providing LSIG overload, short-circuit and ground-fault protection for compatible SACE Tmax T4 moulded case circuit breakers.

SKU: 1SDA054614R1MPN: 1SDA054614R1
Price
List Price £2,524.20 ex VAT
Your Price (ex VAT) Save 25%
£1,893.15 25% OFF
You save £631.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,893.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,893.15

Why Choose the ABB PR222DS/P-LSIG In=250 T4 3p Electronic Trip Unit?

The ABB PR222DS/P-LSIG In=250 T4 3p, order code 1SDA054614R1, is a 250 A three-pole electronic trip unit designed for compatible ABB SACE Tmax T4 moulded case circuit breakers. It provides advanced electronic protection for three-phase AC distribution circuits as part of the modular Tmax T4 circuit breaker system.

The PR222DS/P-LSIG incorporates LSIG protection functions, combining long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. These functions provide comprehensive protection against sustained overloads, high-current faults and earth-fault conditions while supporting coordination within industrial electrical distribution systems.

Supplied as a protection release rather than a complete circuit breaker, the 1SDA054614R1 is intended to be combined with a compatible ABB Tmax T4 breaking part. Its 250 A rated current, three-pole configuration and solid-state protection technology make it suitable for switchboards, machinery, distribution panels and OEM power equipment.

Key Advantages

  • Genuine ABB PR222DS/P-LSIG electronic trip unit.
  • 250 A rated current for compatible Tmax T4 circuit breakers.
  • Three-pole configuration for three-phase AC systems.
  • Comprehensive LSIG electronic protection.
  • Long-time protection against sustained overload conditions.
  • Short-time and instantaneous protection against short-circuit faults.
  • Integrated ground-fault protection.
  • Designed specifically for compatible ABB SACE Tmax T4 circuit breakers.

Key Features

  • PR222DS/P-LSIG electronic protection release.
  • 250 A rated current.
  • Three-pole configuration.
  • L – Long-time overload protection.
  • S – Short-time short-circuit protection.
  • I – Instantaneous short-circuit protection.
  • G – Ground-fault protection.
  • Solid-state electronic current sensing.
  • Designed for compatible ABB SACE Tmax T4 MCCBs.
  • Modular format for circuit breaker assembly, servicing and replacement.

Comprehensive LSIG Protection for ABB Tmax T4

The PR222DS/P-LSIG combines four principal protection functions in one electronic release. Long-time protection responds to sustained overload currents, short-time protection enables controlled response to short-circuit conditions, instantaneous protection provides rapid intervention for severe faults, and ground-fault protection detects damaging current paths to earth.

Because the 1SDA054614R1 is the protection release rather than the complete MCCB, the breaking capacity and installation characteristics of the finished circuit breaker depend on the compatible Tmax T4 breaking part selected for the assembly. ABB's modular approach allows the protection release and breaking unit to be matched to the current rating, fault level and protection requirements of the installation.

Typical Applications

  • ABB SACE Tmax T4 moulded case circuit breaker assemblies.
  • Industrial switchboards and distribution panels.
  • Three-phase AC power distribution circuits.
  • Circuits requiring electronic ground-fault protection.
  • Industrial machinery and process power systems.
  • Compatible Tmax T4 trip-unit replacement applications.
  • OEM electrical distribution and control equipment.

Technical Specifications

Series SACE Tmax T
ABB order code 1SDA054614R1
Product type Electronic trip unit / protection release
Release PR222DS/P-LSIG
Trip technology Electronic / solid-state
Rated current (In) 250 A
Number of poles 3
Protection functions LSIG
Long-time overload protection Yes
Short-time short-circuit protection Yes
Instantaneous short-circuit protection Yes
Ground-fault protection Yes
Compatible circuit breaker ABB SACE Tmax T4
Application Low-voltage power distribution circuit protection
Installation role Protection release for compatible modular MCCB assembly

Frequently Asked Questions

What is the ABB 1SDA054614R1?

The ABB 1SDA054614R1 is a PR222DS/P-LSIG three-pole electronic trip unit rated at 250 A for compatible ABB SACE Tmax T4 moulded case circuit breakers.

What protection functions does the ABB PR222DS/P-LSIG provide?

The PR222DS/P-LSIG provides LSIG protection: long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.

What is the rated current of the ABB 1SDA054614R1?

The electronic trip unit has a rated current of 250 A.

Which circuit breaker is the ABB 1SDA054614R1 designed for?

The 1SDA054614R1 is designed for compatible ABB SACE Tmax T4 moulded case circuit breakers in three-pole configurations.

Is the ABB 1SDA054614R1 a complete circuit breaker?

No. The 1SDA054614R1 is an electronic protection release that must be combined with a compatible ABB Tmax T4 breaking part and any other components required for the completed circuit breaker assembly.

Trusted ABB Electronic Circuit Protection

ABB SACE Tmax electronic trip units provide dependable solid-state protection for modular moulded case circuit breaker assemblies, combining overload, short-circuit and ground-fault protection for demanding industrial power distribution applications.