ABB 1SDA054519R1 T4V 250 PR222DS/P-LSI is a 250 A three-pole fixed moulded case circuit breaker with front terminals for copper cables, LSI electronic protection and ultimate breaking capacities of 20 kA at 1000 V AC and 12 kA at 1150 V AC.

SKU: 1SDA054519R1Alt SKU: T4V250PR222DS/P-LSMPN: 1SDA054519R1
Price
List Price £4,890.20 ex VAT
Your Price (ex VAT) Save 25%
£3,667.65 25% OFF
You save £1,222.55 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,667.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,667.65

Why Choose the ABB T4V 250 PR222DS/P-LSI In=250 3P FFC 1150VAC Circuit Breaker?

The ABB 1SDA054519R1 is a specialist SACE Tmax T4V moulded case circuit breaker (MCCB) designed for demanding AC power distribution applications operating at elevated voltages. This three-pole fixed circuit breaker combines a 250 A rated current with ABB's advanced PR222DS/P-LSI electronic trip unit.

The PR222DS/P-LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These LSI protection functions provide greater flexibility for protection coordination than basic thermomagnetic or instantaneous-only releases, making the breaker particularly useful in specialist industrial distribution systems.

This T4V configuration is designed for operation at up to 1,150 V AC. The V performance level provides an ultimate short-circuit breaking capacity of 20 kA at 1,000 V AC and 12 kA at 1,150 V AC. Fixed mounting and front terminals for copper cables support permanent integration into purpose-built switchboards and high-voltage AC distribution assemblies.

Key Advantages

  • Specialist ABB SACE Tmax T4V moulded case circuit breaker for elevated-voltage AC applications.
  • 250 A rated current for substantial three-phase distribution circuits.
  • Three-pole configuration for three-phase AC systems.
  • PR222DS/P-LSI electronic trip unit for advanced circuit protection.
  • Long-time, short-time and instantaneous protection functions.
  • Suitable for applications operating at up to 1,150 V AC.
  • Ultimate breaking capacity of 20 kA at 1,000 V AC and 12 kA at 1,150 V AC.
  • Fixed construction with front terminals for copper cables.

Key Features

  • ABB SACE Tmax T4 series.
  • T4V 250 frame with V breaking-capacity performance level.
  • 250 A rated current.
  • 3-pole circuit breaker configuration.
  • PR222DS/P-LSI electronic trip unit.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 20 kA Icu at 1,000 V AC.
  • 12 kA Icu at 1,150 V AC.
  • Fixed mounting configuration.
  • Front terminals for copper cables.

Advanced LSI Electronic Protection for Elevated-Voltage AC Systems

The ABB SACE Tmax T4 range includes specialist circuit breakers engineered for AC systems operating at voltages beyond conventional low-voltage distribution levels. The PR222DS/P-LSI release fitted to the 1SDA054519R1 provides long-time, short-time and instantaneous protection, supporting selective and coordinated protection of substantial three-phase circuits.

The T4V performance level provides 20 kA ultimate breaking capacity at 1,000 V AC and 12 kA at 1,150 V AC. Together with its 250 A rating, fixed construction and front copper-cable terminals, this makes the breaker a strong choice for specialist industrial switchboards, power conversion systems and other elevated-voltage AC distribution assemblies.

Typical Applications

  • Industrial power distribution systems operating up to 1,150 V AC.
  • Elevated-voltage three-phase feeder protection.
  • Specialist industrial switchboards and distribution assemblies.
  • Power conversion and industrial energy systems.
  • Manufacturing and process plant electrical installations.
  • Industrial machinery operating at elevated AC voltages.
  • Renewable energy and power-generation auxiliary systems.
  • Applications requiring advanced LSI electronic circuit protection.

Technical Specifications

Series SACE Tmax T4
ABB order code 1SDA054519R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker (MCCB)
Frame T4 250
Performance level V
Rated current (In) 250 A
Number of poles 3P
Trip unit PR222DS/P-LSI electronic release
Protection functions Long-time, short-time and instantaneous
Maximum application voltage 1,150 V AC
Ultimate short-circuit breaking capacity (Icu) at 1,000 V AC 20 kA
Ultimate short-circuit breaking capacity (Icu) at 1,150 V AC 12 kA
Mounting type Fixed
Terminal type Front terminals for copper cables
Net weight 2.5 kg
EAN 8015644556211

Frequently Asked Questions

What is the ABB 1SDA054519R1 used for?

The ABB 1SDA054519R1 is a three-pole moulded case circuit breaker designed for advanced electronic protection and switching in specialist industrial AC distribution systems operating at up to 1,150 V AC.

What is the rated current of the ABB T4V 250 1SDA054519R1?

The circuit breaker has a rated current of 250 A and uses an ABB PR222DS/P-LSI electronic trip unit.

What protection does the PR222DS/P-LSI trip unit provide?

The PR222DS/P-LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What breaking capacity does the ABB 1SDA054519R1 provide?

The T4V circuit breaker provides an ultimate short-circuit breaking capacity of 20 kA at 1,000 V AC and 12 kA at 1,150 V AC.

What terminal configuration does the ABB 1SDA054519R1 use?

The 1SDA054519R1 is a fixed three-pole circuit breaker with front terminals for copper cables, designed for permanent installation within suitable electrical distribution assemblies.

Trusted ABB Protection for Industrial Power Systems

ABB SACE Tmax moulded case circuit breakers provide dependable protection for demanding power distribution systems, with specialist T4V configurations combining advanced electronic protection with operation at AC voltages up to 1,150 V.