1SDA054469R1 ABB T5L630 TMA 500-5000 500 A 3-Pole MCCB

1SDA054469R1 ABB T5L630 TMA 500-5000 500 A 3-Pole MCCB

ABB 1SDA054469R1 SACE Tmax T5L630 fixed three-pole 500 A moulded case circuit breaker with TMA thermomagnetic release, 350–500 A thermal adjustment, 2,500–5,000 A magnetic adjustment and 120 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA054469R1Alt SKU: T5L630MPN: 1SDA054469R1
Price
List Price £5,095.89 ex VAT
Your Price (ex VAT) Save 25%
£3,821.92 25% OFF
You save £1,273.97 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,821.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,821.92

Why Choose the ABB T5L630 TMA 500-5000 500 A 1SDA054469R1 Circuit Breaker?

The ABB 1SDA054469R1 is a high-performance SACE Tmax T5L 630 moulded case circuit breaker (MCCB) designed for dependable protection and isolation in demanding low-voltage power distribution systems. Configured as a fixed three-pole breaker with front terminals, it uses an ABB TMA thermomagnetic trip unit with a rated current of 500 A.

The TMA release combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection. For this version, the thermal setting is adjustable from 350–500 A, while the instantaneous magnetic threshold is adjustable from 2,500–5,000 A, allowing protection to be coordinated with the characteristics of the protected circuit.

As a T5L performance-level breaker, the 1SDA054469R1 provides an ultimate short-circuit breaking capacity (Icu) of 120 kA at 415 V AC. Its combination of a 630 A frame, 500 A thermomagnetic release, three-pole construction and high interruption capability makes it well suited to substantial industrial and commercial distribution circuits.

Key Advantages

  • High-performance ABB SACE Tmax T5L 630 moulded case circuit breaker.
  • 500 A rated current for substantial low-voltage distribution loads.
  • Three-pole configuration for three-phase electrical systems.
  • TMA thermomagnetic release provides overload and short-circuit protection.
  • Adjustable thermal protection from 350–500 A.
  • Adjustable instantaneous magnetic threshold from 2,500–5,000 A.
  • 120 kA Icu at 415 V AC for installations with high prospective fault currents.
  • Fixed construction with front terminals for practical switchboard integration.

Key Features

  • ABB SACE Tmax T5L 630 circuit breaker platform.
  • 500 A rated current.
  • 630 A frame size.
  • 3-pole construction.
  • TMA thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Thermal adjustment range of 350–500 A.
  • Adjustable instantaneous magnetic short-circuit protection.
  • Magnetic adjustment range of 2,500–5,000 A.
  • 120 kA ultimate breaking capacity at 415 V AC.
  • Fixed mounting configuration.
  • Front-terminal connection arrangement.

Reliable Circuit Protection for Power Distribution

The ABB SACE Tmax T5L platform is designed for demanding low-voltage distribution applications requiring substantial current capacity and strong short-circuit interruption performance. The 500 A TMA release combines adjustable thermal overload protection with an adjustable instantaneous magnetic threshold, helping protect conductors and connected equipment against sustained overcurrents and severe short-circuit faults.

With an Icu of 120 kA at 415 V AC, the 1SDA054469R1 is suitable for installations where prospective fault currents can be significant. Its fixed three-pole construction and front terminals provide a practical configuration for integration into industrial switchboards, distribution panels and other low-voltage electrical assemblies.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-main distribution switchboards.
  • High-current three-phase feeder circuits.
  • Manufacturing and process installations.
  • Commercial and infrastructure power distribution.
  • Applications requiring adjustable thermomagnetic overload and short-circuit protection.

Technical Specifications

Series SACE Tmax T5
ABB order code 1SDA054469R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker (MCCB)
Frame T5 630
Performance level L
Rated current (In) 500 A
Number of poles 3
Trip unit TMA thermomagnetic release
Thermal overload adjustment (I1) 350–500 A
Instantaneous magnetic threshold (I3) 2,500–5,000 A
Ultimate breaking capacity (Icu) at 415 V AC 120 kA
Mounting type Fixed
Terminal type Front terminals
Electrical durability 5,000 cycles
Mechanical durability 20,000 cycles
Dimensions (H × W × D) 205 × 140 × 103.5 mm
Net weight 3.25 kg
EAN 8015644555726

Frequently Asked Questions

What is the ABB 1SDA054469R1 used for?

The ABB 1SDA054469R1 is a 500 A three-pole moulded case circuit breaker designed to protect and isolate demanding low-voltage distribution circuits against overload and short-circuit conditions.

What is the current rating of the ABB T5L630 1SDA054469R1?

The circuit breaker uses a 500 A TMA thermomagnetic release and is built on the ABB SACE Tmax T5L 630 frame.

What does TMA 500-5000 mean on the ABB 1SDA054469R1?

The TMA designation identifies the thermomagnetic trip unit. This version has a rated current of 500 A, thermal overload protection adjustable from 350–500 A and an instantaneous magnetic threshold adjustable from 2,500–5,000 A.

What is the breaking capacity of the ABB 1SDA054469R1?

The T5L version provides an ultimate short-circuit breaking capacity (Icu) of 120 kA at 415 V AC, making it suitable for distribution systems with high prospective fault currents.

How is the ABB 1SDA054469R1 installed?

The 1SDA054469R1 is a fixed three-pole circuit breaker with front terminals, designed for integration into low-voltage switchboards and electrical distribution panels.

Trusted Protection from ABB

ABB SACE Tmax moulded case circuit breakers combine robust interruption performance with dependable thermomagnetic protection, providing effective overload and short-circuit protection for demanding industrial and commercial low-voltage distribution systems.