1SDA054452R1 ABB T5V 400 TMA 320-3200 3P F F Moulded Case Circuit Breaker 320 A

1SDA054452R1 ABB T5V 400 TMA 320-3200 3P F F Moulded Case Circuit Breaker 320 A

ABB 1SDA054452R1 T5V 400 TMA is a 320 A three-pole fixed moulded case circuit breaker with front terminals, adjustable thermomagnetic protection and a 200 kA ultimate breaking capacity at 380–415 V AC.

SKU: 1SDA054452R1MPN: 1SDA054452R1
Price
List Price £4,134.41 ex VAT
Your Price (ex VAT) Save 25%
£3,100.81 25% OFF
You save £1,033.60 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,100.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,100.81

Why Choose the ABB T5V 400 TMA 320-3200 3P F F Circuit Breaker?

The ABB 1SDA054452R1 is a high-performance SACE Tmax T5V moulded case circuit breaker (MCCB) designed for dependable overload and short-circuit protection in demanding industrial and commercial low-voltage power distribution systems. This three-pole fixed circuit breaker uses an ABB TMA thermomagnetic trip unit rated at 320 A.

The TMA release combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection. Its thermal setting range is 224–320 A, while the magnetic trip threshold is adjustable from 1,600–3,200 A, allowing protection to be coordinated with the characteristics of the feeder, cables and connected equipment.

The T5V performance level provides an exceptional ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC. Combined with a 400 A frame rating, fixed construction and front terminals, the 1SDA054452R1 is particularly well suited to switchboards and distribution systems where substantial prospective fault currents demand robust interruption performance.

Key Advantages

  • High-performance ABB SACE Tmax T5V moulded case circuit breaker.
  • 320 A rated TMA thermomagnetic release.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Adjustable thermal overload protection from 224–320 A.
  • Adjustable instantaneous magnetic protection from 1,600–3,200 A.
  • Exceptional ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC.
  • 690 V AC rated operational voltage for industrial applications.
  • Fixed construction with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax T5 series.
  • T5V 400 frame with V short-circuit performance level.
  • 320 A rated current.
  • 400 A rated uninterrupted current.
  • 3-pole circuit breaker configuration.
  • TMA thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Adjustable instantaneous magnetic short-circuit protection.
  • 200 kA Icu at 380–415 V AC.
  • 1,000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • Fixed installation with front terminal connections.

Adjustable Thermomagnetic Protection for Power Distribution

Thermomagnetic moulded case circuit breakers such as the ABB SACE Tmax T5V combine thermal overload protection with magnetic short-circuit protection in a robust mechanical package. On the 1SDA054452R1, the thermal release can be adjusted between 224–320 A, while the instantaneous magnetic threshold can be set between 1,600–3,200 A, providing useful flexibility when coordinating protection with the characteristics of the electrical installation.

The 320 A TMA release makes this breaker suitable for substantial three-phase feeders, while the T5V platform's 200 kA ultimate breaking capacity at 380–415 V AC provides exceptionally high fault-current interruption capability. This combination makes the breaker particularly suitable for industrial switchboards and distribution systems where both overload protection and very high short-circuit performance are required.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-distribution switchboards.
  • Three-phase feeder circuit protection.
  • Manufacturing and process plant electrical systems.
  • Commercial building power distribution.
  • Infrastructure and utility electrical installations.
  • Industrial machinery and production facilities.
  • Installations with exceptionally high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T5
ABB order code 1SDA054452R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker (MCCB)
Frame T5 400
Performance level V
Rated current (In) 320 A
Rated uninterrupted current (Iu) 400 A
Number of poles 3P
Trip unit TMA thermomagnetic release
Thermal overload adjustment 224–320 A
Instantaneous magnetic adjustment 1,600–3,200 A
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1,000 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate short-circuit breaking capacity (Icu) at 220–230 V AC 200 kA
Ultimate short-circuit breaking capacity (Icu) at 380–415 V AC 200 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 180 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 80 kA
Rated short-time withstand current (Icw) 5 kA for 1 s
Mounting type Fixed
Terminal type Front terminals
Electrical durability 7,000 operating cycles
Mechanical durability 20,000 operating cycles
Power loss 13.6 W per pole at rated operating conditions
Dimensions (H × W × D) 205 × 140 × 103.5 mm
Net weight 4.8 kg
EAN 8015644555566
Standards IEC

Frequently Asked Questions

What is the ABB 1SDA054452R1 used for?

The ABB 1SDA054452R1 is a three-pole moulded case circuit breaker designed to provide adjustable thermomagnetic overload and short-circuit protection for demanding industrial and commercial low-voltage power distribution systems.

What is the rated current of the ABB T5V 400 TMA 1SDA054452R1?

The circuit breaker has a 320 A rated TMA release within a T5V frame with a rated uninterrupted current of 400 A.

What adjustment ranges does the TMA trip unit provide?

The TMA trip unit provides adjustable thermal overload protection from 224–320 A and adjustable instantaneous magnetic short-circuit protection from 1,600–3,200 A.

What breaking capacity does the ABB 1SDA054452R1 provide?

The T5V circuit breaker provides an ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC, making it suitable for electrical systems with exceptionally high prospective fault currents.

How is the ABB 1SDA054452R1 installed?

The 1SDA054452R1 is a fixed three-pole circuit breaker with front terminals, designed for integration into low-voltage switchboards and distribution assemblies.

Trusted ABB Protection for Industrial Power Systems

ABB SACE Tmax moulded case circuit breakers provide dependable protection for low-voltage distribution systems, combining robust construction, adjustable thermomagnetic protection and high short-circuit interruption capability for demanding industrial, commercial and infrastructure applications.