Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 72.51.0.240.0002 is a conductive liquid level control relay with a 110–240 V AC/DC supply, one 6 A changeover contact, adjustable 5–450 kΩ sensitivity, six filling, emptying and window monitoring functions, selectable 0.5 s or 7 s delays and compact DIN rail mounting for automatic tank and pump control.
£38.47
The Finder 72.51.0.240.0002 is a multifunctional conductive liquid level control relay designed for automatic tank filling, emptying, pump control and liquid level monitoring. Part of the Finder 72 Series, this compact electronic relay uses conductive sensing electrodes to detect liquid levels in tanks, wells, reservoirs and industrial process vessels.
Featuring a wide-range 110–240 V AC/DC power supply, one 6 A changeover output contact and an extended 5–450 kΩ adjustable sensitivity range, the Finder 72.51.0.240.0002 provides flexible monitoring of conductive liquids, including liquids with relatively low electrical conductivity.
With six selectable operating functions, 0.5 s or 7 s switching delays, dual LED status indication and compact 35 mm DIN rail mounting, this level control relay offers a practical solution for water treatment, pumping stations, irrigation, industrial automation and building water management systems.
The Finder 72.51.0.240.0002 monitors liquid levels by detecting electrical conductivity between sensing electrodes installed inside a tank, reservoir, well or process vessel. When the liquid reaches a sensing electrode, the conductive path allows the relay to identify the corresponding level condition and change the state of its output contact according to the selected operating function.
This sensing method is particularly useful for applications involving water and other conductive liquids where automatic filling, emptying or level monitoring is required. Unlike mechanical float switches, conductive electrodes do not rely on a moving float mechanism, although correct electrode positioning, material selection and installation remain essential.
The 5–450 kΩ adjustable sensitivity is a defining feature of the 72.51.0.240.0002 version. Compared with the standard 5–150 kΩ model, the extended sensitivity range enables monitoring of liquids with higher electrical resistance and correspondingly lower conductivity.
The relay also incorporates electrical isolation between the supply, sensing electrodes and output contacts. Its wide-range 110–240 V AC/DC supply makes it particularly convenient for installations where a separate 24 V control supply is not available.
The Finder 72.51.0.240.0002 provides six operating functions selected using the front-mounted function selector. Each function combines a particular level monitoring arrangement with a short or long switching delay.
The filling and emptying functions allow the relay to control suitable pumping or valve systems according to the detected liquid level. Window monitoring provides an additional option for applications requiring detection of a defined level condition.
The selectable delay helps reduce unwanted output switching caused by liquid movement, splashing and temporary changes in electrode contact.
Important: After changing the operating function, the relay must be disconnected from its power supply and then powered on again to apply the new selection.
The Finder 72.51.0.240.0002 is intended for conductive liquids such as drinking water, rainwater, seawater, wastewater and other liquids with sufficient electrical conductivity. It can also be used with certain conductive food and beverage liquids where the electrode materials and installation arrangement are suitable.
The relay is generally not suitable for non-conductive liquids such as petrol, oil, paraffin or highly purified demineralised water. Reliable operation depends on the actual electrical conductivity of the liquid and the correct adjustment of the sensing sensitivity.
Compatible accessories include Finder suspended electrodes, fixed sensing electrodes, electrode holders and associated probe components. Suitable two- or three-electrode arrangements can be selected according to the required level control function and tank construction.
For longer installations, the manufacturer's guidance specifies electrode cable lengths up to 200 m, subject to cable capacitance and correct wiring practices.
| Manufacturer | Finder |
|---|---|
| Series | 72 Series |
| Type | 72.51 |
| Model | 72.51.0.240.0002 |
| Product type | Conductive liquid level control relay |
| Detection principle | Conductive electrode sensing |
| Nominal supply voltage | 110–240 V AC/DC |
| Operating supply range | 88–264 V AC/DC |
| AC supply frequency | 50/60 Hz |
| Rated AC power consumption | 2 VA |
| Rated DC power consumption | 1 W |
| Output contact configuration | 1 CO (SPDT) |
| Rated output current | 6 A |
| Maximum peak output current | 15 A |
| Rated contact voltage | 250 V AC |
| Maximum switching voltage | 400 V AC |
| Rated AC-1 load | 1,500 VA |
| Rated AC-15 load at 230 V AC | 250 VA |
| Single-phase motor rating at 230 V AC | 0.185 kW |
| DC-1 breaking capacity at 24 V DC | 3 A |
| DC-1 breaking capacity at 110 V DC | 0.35 A |
| DC-1 breaking capacity at 220 V DC | 0.2 A |
| Contact material | Silver tin oxide (AgSnO2) |
| Adjustable sensitivity range | 5–450 kΩ |
| Number of operating functions | 6 |
| Filling functions | FL and FS |
| Emptying functions | EL and ES |
| Window monitoring functions | WL and WS |
| Short switching delay | 0.5 s |
| Long switching delay | 7 s |
| Electrode input terminals | B1, B2 and B3 |
| Electrode configurations | Two-electrode or three-electrode operation |
| Maximum electrode cable length | 200 m, subject to cable capacitance limits |
| Maximum specified cable capacitance | 100 nF/km |
| Impulse insulation rating | 6 kV (1.2/50 µs) between specified circuits |
| Status indication | Supply voltage LED and output status LED |
| Operating temperature range | −20 to +60 °C |
| Protection rating | IP20 |
| Mounting type | 35 mm DIN rail |
| DIN rail standard | EN 60715 |
| Terminal construction | Box-clamp terminals |
| Housing width | 17.5 mm |
| EAN | 8012823465623 |
The Finder 72.51.0.240.0002 is a conductive liquid level control relay used for automatic filling, emptying and level monitoring in tanks, wells, reservoirs and industrial water management installations.
The relay operates from a nominal 110–240 V AC/DC supply, with a specified operating voltage range of 88–264 V AC/DC. AC operation supports 50/60 Hz supplies.
The relay provides an extended 5–450 kΩ adjustable sensitivity range, allowing it to detect conductive liquids with different electrical resistance characteristics, including relatively low-conductivity liquids.
Both models have a 110–240 V AC/DC supply and a 6 A changeover output contact. The 72.51.0.240.0000 has a sensitivity range of 5–150 kΩ, while the 72.51.0.240.0002 offers an extended 5–450 kΩ range.
Both models provide 5–450 kΩ adjustable sensitivity and the same general liquid level control functions. The difference is the power supply: the 72.51.0.024.0002 operates from 24 V AC/DC, while the 72.51.0.240.0002 operates from 110–240 V AC/DC.
The Finder 72.51.0.240.0002 provides six selectable functions: filling with short or long delay, emptying with short or long delay, and window monitoring with short or long delay.
The relay provides 0.5 s and 7 s delay options. The delay is selected through the operating function and helps reduce unwanted switching caused by splashing or temporary liquid level changes.
The Finder 72.51.0.240.0002 has one changeover (SPDT) output contact rated at 6 A and 250 V AC. The connected load must remain within the applicable switching and utilisation category ratings.
Yes. The relay can be used for automatic pump control. Smaller loads may be switched directly if they are within the specified contact ratings, while larger motors should be controlled through a suitably rated motor contactor and appropriate protection equipment.
No. The relay operates by measuring conductivity between electrodes and is not suitable for liquids that do not provide sufficient electrical conductivity, such as oil, petrol or highly purified demineralised water.
The relay provides three electrode input terminals and supports suitable two- or three-electrode arrangements, depending on the selected operating function and required level monitoring configuration.
The manufacturer's installation guidance specifies a maximum electrode cable length of 200 m, subject to a cable capacitance limit of 100 nF/km and appropriate installation practices.
Yes. The relay is designed for 35 mm DIN rail mounting according to EN 60715. Its slim 17.5 mm housing makes it suitable for compact electrical control panels.
After changing the operating function, the relay must be disconnected from the supply and then powered on again to ensure that the new operating mode is correctly applied.
The Finder 72.51.0.240.0002 provides flexible conductive liquid level control for industrial, commercial and agricultural applications. Combining a wide-range 110–240 V AC/DC supply, extended 5–450 kΩ sensitivity, six selectable functions and a compact DIN rail housing, it offers a practical solution for electrical engineers, pump installers, control panel builders and water management professionals.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.