clp2ea1c230 - cond.level 2+1 dpdt plug

clp2ea1c230 – cond.level 2+1 dpdt plug

Carlo Gavazzi CLP2EA1C230 plug-in conductive 2-point level controller with filling and emptying functions, adjustable 250 Ω–500 kΩ sensitivity, dual DPDT relay outputs and 230 V AC supply.

SKU: CLP2EA1C230MPN: CLP2EA1C230
Price
List Price £89.93 ex VAT
Your Price (ex VAT) Save 15%
£76.44 15% OFF
You save £13.49 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £76.44
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 5

£76.44

Why Choose the Carlo Gavazzi CLP2EA1C230 Conductive Level Controller?

The Carlo Gavazzi CLP2EA1C230 is a versatile 2-point conductive level controller designed for monitoring and controlling electrically conductive liquids in tanks, reservoirs and industrial process systems. Part of the Carlo Gavazzi CL Series, it provides automatic filling and emptying control using remote conductive probes and offers an adjustable sensitivity range of 250 Ω–500 kΩ.

Designed for high- and low-level control, the CLP2EA1C230 uses two sensing probes plus a reference electrode to monitor the liquid between defined level points. When the liquid reaches or leaves the selected probes, the controller operates its relay outputs according to the filling or emptying function, allowing pumps, contactors, valves and alarm circuits to be controlled automatically.

The CLP2EA1C230 operates from a 230 V AC supply and provides 2 × DPDT relay outputs rated up to 8 A at 250 V AC. Its 11-pin plug-in connection, compact 35.5 × 81 × 60.2 mm housing, IP20 protection and adjustable sensitivity make it a practical solution for industrial liquid-level automation.

Key Advantages

  • Reliable 2-point conductive liquid level monitoring for industrial applications.
  • Supports automatic filling and emptying control.
  • 250 Ω–500 kΩ adjustable sensitivity range accommodates liquids with different conductivity levels.
  • 2 × DPDT relay outputs provide flexible switching and signalling options.
  • Relay contacts rated up to 8 A at 250 V AC.
  • Designed for a standard 230 V AC supply.
  • 11-pin plug-in mounting simplifies installation and replacement.
  • Conductive sensing has no moving parts at the liquid sensing points.

Key Features

  • Carlo Gavazzi CL Series conductive level controller.
  • 2-point high/low level control.
  • Two sensing inputs with reference electrode arrangement.
  • Filling and emptying functions.
  • Adjustable sensitivity from 250 Ω to 500 kΩ.
  • 2 × DPDT (2 Form C) relay outputs.
  • 8 A at 250 V AC relay contact rating.
  • 230 V AC supply voltage.
  • 1 s switching delay.
  • 11-pin plug-in termination.
  • 35.5 × 81 × 60.2 mm housing.
  • IP20 enclosure protection.
  • -20 to +50 °C operating temperature.
  • LED indication for controller status.

How Conductive Liquid Level Control Works

Conductive level controllers monitor liquid by applying a low-level electrical sensing signal between electrodes installed at defined points in a tank or vessel. When a conductive liquid reaches a probe, an electrical path is established through the liquid to the reference electrode and the controller detects the resulting change. The wide 250 Ω–500 kΩ sensitivity range of the CLP2EA1C230 allows it to work with a broad range of conductive media.

For two-point control, high and low sensing probes establish the required switching levels while a reference electrode completes the measurement circuit. The CLP2EA1C230 can use these signals to perform automatic filling or emptying control, operating its relay outputs to control external pumps, contactors or valves. This principle is widely used for water, wastewater and other conductive process liquids where reliable automatic level control is required.

Typical Applications

  • Water tank level control.
  • Automatic tank filling systems.
  • Automatic tank emptying systems.
  • Pump start and stop control.
  • Pump dry-running protection.
  • High- and low-level monitoring.
  • Industrial process tanks and vessels.
  • Water and wastewater treatment equipment.
  • Reservoir and storage tank monitoring.
  • Conductive chemical and process liquid monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Supply Voltage 230 V AC
Coil / Supply Voltage 230 V AC
IP Rating IP20
Output Type Relay
Sensing Principle Level (conductive)
Manufacturer Carlo Gavazzi
Series CL / CLP
Model CLP2EA1C230
Product type Conductive 2-point level controller
Detection principle Conductive liquid level sensing
Number of input probes 2 plus reference electrode
Control function Filling / emptying
Sensitivity range 250 Ω–500 kΩ
Sensitivity Adjustable
Output 2 × DPDT relay
Contact form DPDT / 2 Form C
Relay contact rating 8 A at 250 V AC
Supply voltage 230 V AC
Supply operating range 195–265 V AC
On-delay 1 s
Off-delay 1 s
Connection 11-pin plug-in
Mounting Socketable / plug-in
Housing dimensions 35.5 × 81 × 60.2 mm
Protection rating IP20
Operating temperature -20 to +50 °C
Suitable media Electrically conductive liquids

Frequently Asked Questions

What is the Carlo Gavazzi CLP2EA1C230 used for?

The CLP2EA1C230 is a 2-point conductive liquid level controller designed for automatic filling, emptying and high/low level monitoring of tanks and vessels containing electrically conductive liquids.

What supply voltage does the CLP2EA1C230 require?

The CLP2EA1C230 is the 230 V AC version of the CLP2 level controller, with a specified AC operating range of approximately 195–265 V AC.

What is the sensitivity range of the CLP2EA1C230?

The controller provides an adjustable sensitivity range of 250 Ω–500 kΩ, allowing it to detect a wide range of electrically conductive liquids.

What outputs does the CLP2EA1C230 provide?

The CLP2EA1C230 provides 2 × DPDT relay outputs with contacts rated up to 8 A at 250 V AC, providing flexible switching for compatible pumps, contactors, valves and alarm circuits.

How is the Carlo Gavazzi CLP2EA1C230 installed?

The CLP2EA1C230 uses an 11-pin plug-in connection and is installed using a compatible socket, allowing convenient panel installation and straightforward controller replacement during maintenance.

Reliable Conductive Level Control for Industrial Systems

Carlo Gavazzi CL Series controllers provide dependable conductive liquid level monitoring for industrial automation, with the CLP2EA1C230 combining two-point filling and emptying control, adjustable 250 Ω–500 kΩ sensitivity, dual DPDT relay outputs and convenient 11-pin plug-in installation.