ca18cll12bp - cap prox pl m18 npn/pnp teach cab

ca18cll12bp – cap prox pl m18 npn/pnp teach cab

Carlo Gavazzi CA18CLL12BP is a flush-mountable M18 TRIPLESHIELD capacitive proximity and level sensor with a 0.5–12 mm teach-in sensing range, 10–40 V DC supply, automatic NPN/PNP output, selectable NO/NC operation, 2 m PVC cable and IP68 protection.

SKU: CA18CLL12BPMPN: CA18CLL12BP
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Carlo Gavazzi CA18CLL12BP Capacitive Proximity Sensor?

The Carlo Gavazzi CA18CLL12BP is a high-performance M18 capacitive proximity and level sensor designed for reliable non-contact detection of liquids, dry bulk materials and other conductive or non-conductive targets. Part of the Carlo Gavazzi CA18 TRIPLESHIELD™ series, it combines single-step teach-in adjustment with automatic NPN/PNP load detection for flexible integration into industrial automation and process-control systems.

The CA18CLL12BP provides an adjustable 0.5–12 mm sensing range, allowing the detection point to be configured to suit the target material and installation. Its three-wire DC output automatically detects an NPN or PNP load, while normally open or normally closed switching can be selected through the teach-in function. Humidity compensation helps maintain stable operation in applications where environmental conditions may affect conventional capacitive sensors.

Operating from a 10–40 V DC supply, the sensor features a flush-mountable M18 thermoplastic polyester housing and a 2 m PVC cable. TRIPLESHIELD™ protection, short-circuit protection, reverse-polarity protection, transient protection and an IP68 enclosure rating make the CA18CLL12BP particularly suitable for demanding level-detection and industrial sensing applications.

Key Advantages

  • Versatile capacitive detection of liquids, dry bulk materials and non-metallic targets.
  • 0.5–12 mm adjustable sensing range with single-step teach-in configuration.
  • Automatic NPN/PNP load detection simplifies connection to different control systems.
  • Selectable normally open (NO) or normally closed (NC) switching operation.
  • Humidity compensation helps improve sensing stability under changing environmental conditions.
  • TRIPLESHIELD™ sensor protection supports reliable operation in electrically demanding industrial environments.
  • IP68 protection provides excellent resistance to dust and moisture ingress.
  • Sensing face withstands temperatures up to 120 °C for demanding level-detection applications.

Key Features

  • Carlo Gavazzi CA18 TRIPLESHIELD™ series.
  • M18 threaded capacitive proximity and level sensor.
  • 0.5–12 mm teach-in sensing range.
  • 10–40 V DC operating voltage.
  • Automatic NPN/PNP output load detection.
  • Selectable NO/NC switching function.
  • Three-wire DC output with NPN alarm functionality.
  • 5 Hz operating frequency.
  • Maximum output current of 250 mA.
  • Single-step teach-in via push-button or control input.
  • Humidity compensation and remote setup functionality.
  • Alarm output for unsafe operation or heavy contamination of the sensing surface.
  • 2 m PVC cable connection.
  • Short-circuit, transient and reverse-polarity protection.
  • IP68-rated thermoplastic polyester housing.

Reliable Capacitive Level Detection for Industrial Processes

Capacitive sensors detect changes in capacitance at the sensing face, enabling them to detect materials that cannot be reliably sensed using conventional inductive proximity switches. The CA18CLL12BP is particularly suited to liquid and dry bulk material detection and can be used with materials including plastics, rubber compounds, powders, granulates and fluids.

The single-step teach-in function allows the sensing distance and switching behaviour to be configured for the application, while automatic NPN/PNP load detection simplifies control-system integration. Humidity compensation, TRIPLESHIELD™ protection and the integrated alarm function further improve reliability by helping identify unsuitable operating conditions or significant contamination at the sensing surface.

Typical Applications

  • Liquid level detection in tanks and containers.
  • Dry bulk material, powder and granulate level monitoring.
  • Plastic and rubber processing machinery.
  • Packaging, filling and dispensing equipment.
  • Plastic, glass and non-metallic object detection.
  • Industrial conveyors and material handling systems.
  • Process control and production machinery.
  • OEM automation and machine-building applications.

Technical Specifications

Tick the specs you need, then view products that match.

Coil / Supply Voltage 10–40 V DC
Mounting Condition Flush
IP Rating IP68
Output Type NPN, PNP
Sensing Principle Capacitive
Housing Size M18
Sensing Distance 12 mm
Output Function Selectable NO/NC
Connection Cable
Manufacturer Carlo Gavazzi
Series CA18 TRIPLESHIELD™
Model CA18CLL12BP
Product type Capacitive proximity / level sensor
Sensing principle Capacitive
Housing format Cylindrical threaded barrel
Thread M18 × 1 × 50 mm
Mounting Flush
Sensing range 0.5–12 mm adjustable
Adjustment Single-step teach-in
Supply voltage 10–40 V DC
Output configuration Automatic NPN / PNP
Output function Selectable NO / NC
Output current ≤250 mA
Voltage drop ≤2.5 V DC
Operating frequency 5 Hz
Connection Pre-wired PVC cable
Cable length 2 m
Housing dimensions M18 × 89.55 mm
Housing material Thermoplastic polyester
LED indication Yellow
Protection rating IP68
Operating temperature -20 to +85 °C
Maximum sensing-face temperature 120 °C
Protection functions Short-circuit, transient and reverse-polarity protection
Special functions Humidity compensation, remote setup and alarm output
Approvals / marks CE, UL and CSA

Frequently Asked Questions

What is the Carlo Gavazzi CA18CLL12BP used for?

The CA18CLL12BP is a capacitive proximity and level sensor designed for non-contact detection of liquids, dry bulk materials and other conductive or non-conductive targets in industrial automation and process applications.

What is the sensing range of the CA18CLL12BP?

The sensor provides an adjustable sensing distance of 0.5–12 mm, configured using its single-step teach-in function.

Does the CA18CLL12BP have an NPN or PNP output?

The CA18CLL12BP provides automatic NPN/PNP load detection and supports selectable normally open or normally closed switching operation.

What supply voltage does the CA18CLL12BP require?

The sensor operates from a 10–40 V DC supply and can switch loads up to 250 mA.

Is the CA18CLL12BP suitable for level detection?

Yes. The CA18CLL12BP is specifically suited to liquid and dry bulk material level detection, with teach-in adjustment, humidity compensation and an alarm output helping provide reliable operation in industrial process applications.

Trusted by Industrial Automation Engineers

Carlo Gavazzi CA18 TRIPLESHIELD™ capacitive sensors combine teach-in configuration, automatic NPN/PNP detection, humidity compensation and robust environmental protection for dependable level and presence sensing in industrial automation.