Pizzato FY 60FD1E1Z-F20 is a 24 V AC/DC FY series safety interlock switch with separate F20 actuator, energised solenoid guard locking and a 2 NO + 2 NC contact arrangement for industrial machine guarding.
£101.46
The Pizzato FY 60FD1E1Z-F20 is an industrial safety switch with separate actuator and solenoid guard locking from the Pizzato FY series, designed for monitoring and controlling access through movable guards, doors and protective barriers on machinery. Its combined interlocking and locking functions make it suitable for automated equipment where guard position and lock status need to be incorporated into the machine control system.
The FY 60FD1E1Z-F20 uses a 24 V AC/DC solenoid and the FY family's 60F slow-action contact configuration, providing 1 NO actuator-operated contact plus 1 NO + 2 NC solenoid-operated contacts. This gives a total contact arrangement of 2 NO + 2 NC for signalling the state of the separate actuator and locking mechanism.
The E1Z configuration provides energised guard locking, retaining the actuator when the solenoid is powered, while the F20 suffix identifies the supplied actuator configuration. This makes the FY 60FD1E1Z-F20 a practical complete interlocking solution for industrial machine guards, automated production equipment and safety-related access-control applications.
Safety interlock switches with guard locking allow a machinery control system to monitor a movable protective guard while also controlling whether the guard actuator can be withdrawn. The Pizzato FY 60FD1E1Z-F20 combines these functions in a single assembly, providing separate electrical signalling for actuator position and the solenoid-operated locking mechanism.
With its energised locking arrangement, the actuator is mechanically retained when the locking solenoid is powered. The F20 actuator provides the corresponding mechanical interface on the movable guard, making this configuration suitable for machinery where guard locking is deliberately controlled through the electrical safety and automation system.
Tick the specs you need, then view products that match.
| Housing Material | Technopolymer | |
|---|---|---|
| Device Type | Guard-locking switch | |
| Product Series | Pizzato FY | |
| Safety Switch Type | Guard locking (solenoid) | |
| Guard Locking | Power to lock | |
| Manufacturer | Pizzato Elettrica | |
| Series | FY | |
| Model | FY 60FD1E1Z-F20 | |
| Alternative SKU | FY60FD1E1ZF20 | |
| Product type | Safety switch with separate actuator and guard locking | |
| Actuation type | Separate actuator | |
| Contact operation | Slow action | |
| Locking principle | Energised solenoid locking | |
| Lock condition | Actuator locked with solenoid energised | |
| Solenoid supply | 24 V AC/DC | |
| Actuator contact configuration | 1 NO | |
| Solenoid contact configuration | 1 NO + 2 NC | |
| Total contact configuration | 2 NO + 2 NC | |
| Actuator configuration | F20 | |
| Application | Industrial machine guard monitoring and locking | |
| Barcode / EAN | 8018851601361 | |
| Packed quantity | 1 | |
| HS Code | 85369095 |
The FY 60FD1E1Z-F20 is designed to monitor and mechanically lock movable machine guards and access doors as part of an industrial machinery safety and control system.
The switch uses an energised locking arrangement, meaning the separate actuator is mechanically retained when the locking solenoid is energised.
The locking solenoid operates from a 24 V AC/DC supply.
The FY 60FD1E1Z-F20 provides 1 NO actuator-operated contact together with 1 NO + 2 NC solenoid-operated contacts, giving a combined arrangement of 2 NO + 2 NC.
The F20 suffix identifies the actuator configuration associated with this FY series safety-switch variant, providing the mechanical interface between the movable guard and the switch.
With energised locking, electrical power to the solenoid causes the actuator to be retained. De-energised locking variants instead mechanically retain the actuator when the locking solenoid is not powered.
Yes. Its actuator-operated and solenoid-operated contacts provide separate electrical signalling that can be incorporated into an appropriately designed system for guard-position and locking-status monitoring.
Typical applications include industrial machine guards, robotic cells, automated production lines, packaging equipment, conveyors and other machinery requiring controlled guard locking.
Pizzato Elettrica FY series safety switches are used in industrial machinery and automation applications where dependable guard monitoring, controlled guard locking and integration with machine safety control systems are required.