CS ME-20VU24-TF2 Pizzato Expansion module 4NO+2NC, delayed at de-energizing

CS ME-20VU24-TF2 Pizzato Expansion module 4NO+2NC, delayed at de-energizing

Pizzato CSME-20VU24-TF2 expansion module with delayed de-energising outputs, 4 NO and 2 NC contacts, designed for controlled shutdown in industrial safety systems.

SKU: CSME-20VU24-TF2Alt SKU: CSME20VU24TF2MPN: CS ME-20VU24-TF2
Price
List Price £136.91 ex VAT
Your Price (ex VAT) Save 15%
£116.37 15% OFF
You save £20.54 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 4-5 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £116.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£116.37

Why Choose the Pizzato CSME-20VU24-TF2 Expansion Safety Module?

The Pizzato CSME-20VU24-TF2 is a high-performance safety expansion module with delayed output functionality, designed to enhance industrial safety systems. As part of the advanced Pizzato CS ME series, it provides additional safety outputs combined with controlled delay behaviour for improved machine protection.

This module features delayed de-energising outputs (TF2 function), allowing machinery to stop in a controlled and predictable manner. This is essential in applications where immediate shutdown could cause mechanical stress or safety risks.

Operating on a 24 V DC supply, the CSME-20VU24-TF2 provides 4 normally open (NO) safety contacts and 2 normally closed (NC) contacts, plus a feedback contact. It is designed for DIN rail mounting, enabling easy integration into control panels and safety systems.

Key Advantages

  • Expansion module for safety systems, increasing output capacity.
  • Delayed de-energising function (TF2) for controlled shutdown.
  • 4 NO + 2 NC contact configuration for flexible safety circuit design.
  • 24 V DC operation suitable for industrial control systems.
  • Integrated feedback circuit for monitoring and diagnostics.
  • Improves safety performance in emergency stop and fault conditions.

Key Features

  • Pizzato CS ME series expansion module.
  • Delayed output contacts at de-energising (TF2).
  • 4 NO safety contacts + 2 NC contacts + 1 NC feedback.
  • Supports single or dual-channel safety systems.
  • Screw terminal connections for secure installation.
  • Compact DIN rail mounting design.

Controlled Safety Shutdown for Industrial Machinery

Safety modules such as the Pizzato CSME-20VU24-TF2 are essential where controlled stop sequences are required. The delayed de-energising function ensures that outputs remain active for a defined period after a stop signal, allowing machinery to decelerate safely.

This functionality is particularly valuable in systems with inertia, such as conveyors, rotating machinery and automated production lines, where sudden stops could lead to damage or hazards.

Typical Applications

  • Safety circuits requiring delayed shutdown functionality.
  • Industrial conveyors and material handling systems.
  • Machine guarding and emergency stop systems.
  • Packaging and processing machinery.
  • Automation systems with controlled stopping requirements.
  • OEM machinery and control panel integration.

Technical Specifications

Tick the specs you need, then view products that match.

Contacts 4NO + 2NC
SIL (up to) SIL 3
Timing Function Off-delay
Mounting Type DIN rail
Terminal Type Screw
Auxiliary Contacts 2 NC
Safety Functions Contact expansion, Delayed outputs
Device Type Safety timing relay
Safety Outputs 4NO + 2NC
Output Type Relay contacts
Product Series Pizzato CS ME
Voltage 24 V
Coil / Supply Voltage 24 V DC
Series CS ME
Product type Safety expansion module with delayed outputs
Supply voltage 24 V DC
Function Contact expansion with delayed de-energising (TF2)
Contact configuration 4 NO + 2 NC + 1 NC feedback
Mounting type DIN rail
Connection type Screw terminals
Application Industrial safety circuits requiring controlled shutdown
HS Code 85369095

Frequently Asked Questions

What is the Pizzato CSME-20VU24-TF2 used for?

It is used to expand safety relay outputs while providing a delayed shutdown function in industrial safety systems.

What does the TF2 function mean?

TF2 refers to delayed de-energising outputs, allowing machinery to stop safely over a defined period.

How many contacts does this module provide?

It provides 4 normally open safety contacts and 2 normally closed contacts, plus a feedback contact.

What supply voltage does the module require?

The CSME-20VU24-TF2 operates on a 24 V DC power supply.

Where is this module typically installed?

It is installed on DIN rail inside industrial control panels as part of safety relay systems.

Trusted by Machine Builders Worldwide

Pizzato safety expansion modules are widely used by automation engineers to ensure reliable, controlled and compliant machine shutdown in demanding industrial environments.