CS FS-13X120 Pizzato Safety module 1NO+2NC, delayed at energizing

CS FS-13X120 Pizzato Safety module 1NO+2NC, delayed at energizing

Pizzato CS FS-13X120 is a 120 V AC delay-at-energisation safety timer module with one delayed NO safety contact and two delayed NC signalling contacts for Category 4, PL e and SIL 3 machinery safety applications.

SKU: CSFS-13X120Alt SKU: CSFS13X120MPN: CS FS-13X120
Price
List Price £140.30 ex VAT
Your Price (ex VAT) Save 15%
£119.26 15% OFF
You save £21.05 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 4-5 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £119.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£119.26

Why Choose the Pizzato CS FS-13X120 Safety Timer Module?

The Pizzato CS FS-13X120 is a dedicated safety timer module designed for industrial safety circuits requiring delayed switching after energisation. Part of the Pizzato CS FS safety module series, it combines one normally open safety output with two normally closed signalling outputs for safety-related timed control.

The CS FS-13X120 operates from a 120 V AC supply and provides 1NO+2NC outputs delayed at energisation. Its safety architecture supports applications up to Category 4, Performance Level e (PL e) and SIL 3, making it suitable for demanding machinery safety systems where a controlled time delay is required.

Removable connectors with spring terminals, a start input, feedback loop and DIN rail compatibility simplify integration into industrial control cabinets. These features make the CS FS-13X120 a practical choice for machine builders requiring dependable delayed safety switching from a 120 V AC control supply.

Key Advantages

  • Dedicated delay-at-energisation safety function.
  • Provides 1NO safety output and 2NC signalling outputs.
  • Designed for safety functions up to Category 4.
  • Supports Performance Level e (PL e).
  • Supports safety integrity applications up to SIL 3.
  • 120 V AC supply suits compatible industrial control systems.
  • Integrated start input and feedback loop support monitored safety circuits.
  • Removable spring-terminal connectors simplify wiring and servicing.

Key Features

  • Pizzato CS FS safety module series.
  • Safety timer module for industrial machinery.
  • Outputs delayed at energisation.
  • 120 V AC supply voltage.
  • 1NO delayed safety output.
  • 2NC delayed signalling outputs.
  • Category 4 safety capability.
  • PL e according to EN ISO 13849-1.
  • SIL 3 safety integrity capability.
  • Integrated feedback loop.
  • Integrated start input.
  • Removable connectors with spring terminals.
  • Suitable for DIN rail mounting.
  • UL approved.

Delayed Safety Switching for Industrial Machinery

The Pizzato CS FS-13X120 is designed for safety functions where output switching must occur after energisation rather than immediately. Its timed operating principle enables machine designers to introduce a controlled delay into a safety-related sequence while retaining monitored safety functionality.

The module combines one delayed normally open safety contact with two delayed normally closed signalling contacts. Together with its Category 4, PL e and SIL 3 capability, start input and feedback loop, this configuration supports the integration of high-integrity timed functions into appropriate machinery safety systems.

Typical Applications

  • Delayed activation of safety-related circuits.
  • Timed industrial machinery safety functions.
  • Safety-related machine sequencing.
  • Interlocked machine safety systems.
  • Controlled enabling of machinery circuits.
  • Packaging and processing machinery.
  • Automated production and assembly equipment.
  • Machine tools and material handling equipment.
  • OEM machinery and automation systems.
  • Industrial safety control panels.

Technical Specifications

Tick the specs you need, then view products that match.

Contacts 1NO + 2NC
SIL (up to) SIL 3
Timing Function On-delay
Mounting Type DIN rail
Terminal Type Spring clamp
Auxiliary Contacts 2 NC
Safety Functions Delayed outputs
Device Type Safety timing relay
Safety Outputs 1NO + 2NC
Output Type Relay contacts
Product Series Pizzato CS FS
Coil / Supply Voltage 120 V AC
Manufacturer Pizzato Elettrica
Series CS FS Safety Modules
Model CS FS-13X120
Alternative SKU CSFS13X120
EAN 8018851595455
Product type Safety timer module
Function Delayed at energisation
Supply voltage 120 V AC
Safety outputs 1NO delayed contact
Signalling outputs 2NC delayed contacts
Maximum safety category Category 4
Maximum performance level PL e
Maximum SIL SIL 3
Start input Yes
Feedback loop Yes
Terminal type Removable connectors with spring terminals
Mounting type DIN rail
UL approval Yes
HS Code 85369095

Frequently Asked Questions

What is the Pizzato CS FS-13X120?

The CS FS-13X120 is a safety timer module providing delayed-at-energisation relay outputs for safety-related industrial machinery applications.

What supply voltage does the CS FS-13X120 use?

The Pizzato CS FS-13X120 operates from a 120 V AC supply.

What outputs does the CS FS-13X120 provide?

The module provides one normally open delayed safety contact together with two normally closed delayed signalling contacts.

Is the CS FS-13X120 delayed at energisation?

Yes. The CS FS-13X120 is specifically designed with its outputs delayed at energisation, enabling controlled timed switching after the module is energised.

What safety level does the CS FS-13X120 support?

The module supports safety functions up to Category 4, Performance Level e (PL e) and SIL 3 when correctly incorporated into the complete safety-related control system.

Does the CS FS-13X120 have a feedback loop?

Yes. The CS FS-13X120 provides a feedback loop for monitoring appropriate external switching devices within the safety circuit.

Does the CS FS-13X120 provide a start input?

Yes. A start input is provided for integration into appropriate safety-related control architectures.

What terminal type does the CS FS-13X120 use?

The CS FS-13X120 uses removable connectors with spring terminals, providing secure industrial wiring while simplifying installation and module replacement.

How is the Pizzato CS FS-13X120 mounted?

The module is suitable for DIN rail mounting inside an appropriate industrial control enclosure.

Trusted by Machine Builders Worldwide

Pizzato Elettrica CS FS safety timer modules provide machine builders, control-panel manufacturers and automation engineers with dependable delayed safety switching for machinery sequencing and other safety-related industrial control applications.