ABB JSR2A expansion relay 10A 24AC/DC

ABB JSR2A expansion relay 10A 24AC/DC

ABB JSR2A 2TLA010027R0100 is a 24 V AC/DC high-capacity safety expansion relay with four normally open safety outputs, one normally closed information output and switching capability up to 10 A for expanding industrial machine safety systems.

SKU: 2TLA010027R0100Alt SKU: JSR2AMPN: 2TLA010027R0100
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB JSR2A 2TLA010027R0100 Safety Expansion Relay?

The ABB JSR2A 2TLA010027R0100 is a high-capacity safety expansion relay designed to increase the number of safety outputs available from a compatible safety relay in industrial machinery and automation systems. Part of the ABB Jokab Safety JSR range, the JSR2A combines redundant relay operation with high switching capacity, making it particularly suitable where additional safety contacts are required for contactors, valves and other safety-related equipment.

The JSR2A is connected to and monitored by a suitable safety relay and can be configured for either single-channel or dual-channel operation. Its mechanically positively guided internal relays provide reliable fault monitoring, while the monitoring circuit allows the controlling safety relay to verify that both internal relays have returned to their safe state before permitting a new machine start.

Operating from a 24 V AC/DC supply, the JSR2A provides 4 NO safety outputs plus 1 NC information output. Its high-capacity contacts can switch resistive loads up to 10 A at 24–115 V AC or 8 A at 230 V AC, making this expansion relay suitable for demanding industrial machine safety applications.

Key Advantages

  • High-capacity safety expansion relay for increasing safety system outputs.
  • 24 V AC/DC supply provides flexible integration into industrial control systems.
  • 4 NO safety outputs plus 1 NC information output.
  • Resistive switching capacity up to 10 A at 24–115 V AC.
  • Supports both single-channel and dual-channel connection.
  • Mechanically positively guided relay contacts enable reliable monitoring.
  • Safety performance up to PL e / Category 4 / SIL 3 when correctly incorporated into a suitable safety system.
  • Detachable connector blocks simplify installation and maintenance.

Key Features

  • ABB Jokab Safety JSR2A safety expansion relay.
  • 24 V AC/DC supply.
  • 50–60 Hz AC supply frequency.
  • 4 NO + 1 NC relay outputs.
  • Up to 10 A resistive AC switching capacity at lower AC voltages.
  • 8 A at 230 V AC resistive switching capacity.
  • 8 A at 24 V DC resistive switching capacity.
  • Maximum total resistive switching current of 16 A distributed across all contacts.
  • Single-channel or dual-channel operation.
  • Activation response time of <15 ms.
  • Deactivation response time of <25 ms.
  • LED indication for supply and output relay status.
  • 35 mm DIN-rail mounting with detachable connector blocks.

High-Capacity Safety Output Expansion for Industrial Machinery

Safety expansion relays such as the ABB JSR2A increase the number of safety contacts available from an existing safety relay. When its safety inputs are energised, the redundant internal K1 and K2 relays operate the output contacts. If the inputs open or the power supply fails, both internal relays drop out and the safety outputs return to their de-energised state.

The JSR2A is designed to be monitored by the safety relay it expands. Monitoring terminals can be connected to the test or reset circuit of the controlling safety relay so that the condition of the positively guided internal relays is checked before another ready signal is permitted. This provides a practical way to add high-capacity outputs while maintaining the required safety architecture.

Typical Applications

  • Expanding the outputs of industrial safety relays.
  • Emergency-stop systems requiring additional safety contacts.
  • Machine guard and interlock safety circuits.
  • Control of multiple safety contactors.
  • Safety-related valve and actuator control.
  • Industrial machinery and automated production equipment.
  • Manufacturing and material handling systems.
  • Control panels requiring additional high-capacity safety outputs.

Technical Specifications

Tick the specs you need, then view products that match.

SIL (up to) SIL 3
Timing Function None (instantaneous)
Auxiliary Contacts None
Current 10 A
Coil / Supply Voltage 24 V AC, 24 V DC
IP Rating IP20, IP40
Manufacturer ABB
Product family ABB Jokab Safety
Series JSR2A / JSR
Model JSR2A 10A 24AC/DC
Article number 2TLA010027R0100
Product type Safety expansion relay
Supply voltage 24 V AC/DC
AC supply frequency 50–60 Hz
Power consumption 2.7 W / 2.4–4 VA
Safety outputs 4 NO
Information output 1 NC
Operating configuration Single-channel / dual-channel
Resistive AC switching capacity at 230 V AC 8 A / 1840 VA
Resistive AC switching capacity at 24–115 V AC up to 10 A / 1840 VA
Inductive AC switching capacity AC-15, 4 A NO / 1.5 A NC at 230 V AC
Resistive DC switching capacity 8 A at 24 V DC / 192 W
Inductive DC switching capacity DC-13, 1.2 A at 24 V DC
Maximum total resistive switching current 16 A distributed across all contacts
Minimum load 10 mA at 10 V / 100 mW
Contact material AgSnO2 + Au flash
Recommended external output fuse 6 A gL
Conditional short-circuit current protection 10 A gG at 1 kA
Maximum input wire resistance 100 Ω at 24 V AC/DC
Activation response time <15 ms
Deactivation response time <25 ms
Mechanical operational life >107 operations
Maximum safety performance PL e / Category 4 / SIL 3
PFHD 1.55 × 10-8
Impulse withstand voltage 2.5 kV
Pollution degree 2
Protection rating IP40 enclosure / IP20 terminals
Operating temperature -10–+55 °C
Operating humidity 35–85%
LED indication Supply voltage and output relays
Terminal type Detachable connector blocks
Mounting type 35 mm DIN rail
Dimensions (W × H × D) 45 × 74 × 120 mm
Weight approximately 313 g

Frequently Asked Questions

What is the ABB JSR2A 2TLA010027R0100 used for?

The ABB JSR2A is a safety expansion relay used to increase the number and switching capacity of safety outputs available from a compatible safety relay in industrial machine safety systems.

What supply voltage does the ABB JSR2A 2TLA010027R0100 require?

This version of the JSR2A operates from a 24 V AC/DC supply, with AC operation at 50–60 Hz.

How many outputs does the ABB JSR2A provide?

The JSR2A provides 4 normally open safety outputs and 1 normally closed information output.

What is the switching capacity of the ABB JSR2A?

The JSR2A can switch resistive loads up to 10 A at 24–115 V AC, 8 A at 230 V AC and 8 A at 24 V DC, subject to the specified total contact loading limits.

Can the ABB JSR2A be used as a standalone safety relay?

The JSR2A is designed as an expansion relay connected to and monitored by a suitable safety relay. It can be connected for either single-channel or dual-channel operation as part of the overall safety system.

Trusted ABB Jokab Safety Technology

ABB Jokab Safety JSR2A expansion relays provide dependable high-capacity safety output expansion for industrial machinery, combining redundant positively guided relay operation with flexible single-channel or dual-channel connection and compact DIN-rail installation.