Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB JSBR4 2TLA010002R0400 is a 115 V AC dual-channel machine safety relay with 3 NO safety outputs, 1 NC information output, supervised manual reset and 0.5 s input synchronisation for two-hand controls and other industrial safety applications.
The ABB JSBR4 115AC 2TLA010002R0400 is a dedicated machine safety relay designed for monitoring two-hand control devices and a wide range of other industrial safety functions. Part of the proven ABB Jokab Safety JSB series, the JSBR4 combines dual-channel monitoring, supervised manual reset and positively guided relay outputs to provide dependable safety control in machinery and automation systems.
This version operates from a 115 V AC, 50–60 Hz supply and provides 3 NO safety outputs plus 1 NC information output. The relay supports dual-channel safety circuits with a synchronisation time of 0.5 s, making it particularly suitable for two-hand control applications where both input channels must operate within a defined time interval.
The JSBR4 also incorporates a test input for monitoring external positively guided relays and contactors, supervised manual reset and three LED status indicators. Its compact 45 mm wide DIN rail housing, removable terminal blocks and Category 4 safety capability make it a practical solution for established industrial machine-safety installations.
The ABB JSBR4 monitors safety input circuits and only enables its safety outputs when the required operating and reset conditions have been satisfied. Its dual-channel architecture and 0.5 s synchronisation monitoring make it especially effective for two-hand control systems, where both actuating devices must be operated within the permitted time interval before hazardous machine movement can be enabled.
The relay can also be integrated with emergency stops, interlocking switches, safety mats, contact strips and other safety devices. Supervised reset and external contactor monitoring provide additional control over the safety circuit, while the positively guided output contacts allow the JSBR4 to form part of high-integrity machinery safety systems.
Tick the specs you need, then view products that match.
| SIL (up to) | SIL 3 | |
|---|---|---|
| Timing Function | None (instantaneous) | |
| Auxiliary Contacts | None | |
| Reset Type | Manual | |
| Coil / Supply Voltage | 115 V AC | |
| Manufacturer | ABB | |
| Product family | ABB Jokab Safety | |
| Series | JSB | |
| Model | JSBR4 115AC | |
| Manufacturer part number | 2TLA010002R0400 | |
| Product type | Safety relay | |
| Rated control supply voltage | 115 V AC | |
| Supply tolerance | ±15% | |
| Supply frequency | 50–60 Hz | |
| Power consumption | 3.3 VA | |
| Safety outputs | 3 NO | |
| Information output | 1 NC | |
| Maximum switching capacity | 6 A at 250 V AC / 1500 VA resistive load | |
| AC-15 rating | 2 A at 240 V AC | |
| DC resistive switching capacity | 6 A at 24 V DC / 150 W | |
| DC-13 rating | 1 A at 24 V DC | |
| Input configuration | Dual channel | |
| Input synchronisation | 0.5 s | |
| Reset | Manual supervised reset | |
| Status indication | 3 LED indicators | |
| Safety category | Category 4 | |
| Mounting | 35 mm DIN rail | |
| Housing protection | IP40 | |
| Terminal protection | IP20 | |
| Operating temperature | -10 to +55 °C | |
| Width | 45 mm | |
| Height | 74 mm | |
| Depth | 120 mm | |
| Net weight | 0.46 kg | |
| Colour | Black and beige | |
| EAN | 7350024432596 |
The ABB JSBR4 2TLA010002R0400 is a machine safety relay designed particularly for two-hand control devices, while also supporting applications including emergency stops, interlocking switches, safety mats and contact strips.
This JSBR4 version operates from a 115 V AC, 50–60 Hz supply with a rated supply tolerance of ±15%.
The relay provides 3 normally open safety outputs and 1 normally closed information output.
Yes. Two-hand control is a principal application of the JSBR4. It uses dual-channel monitoring with a 0.5 s synchronisation time to supervise the two input channels.
Yes. The JSBR4 incorporates a manual supervised reset, helping ensure that the safety circuit is deliberately reset before machine operation resumes.
Yes. A test input enables the safety relay to monitor external positively guided relays or contactors used within the machine safety circuit.
The relay is designed for installation on a standard 35 mm DIN rail inside an electrical control panel and has a compact width of 45 mm.
The ABB JSBR4 is designed for safety applications up to Category 4 when correctly incorporated into an appropriately designed and validated machine safety system.
ABB Jokab Safety JSBR4 relays have been used in industrial machinery safety systems for two-hand controls, emergency stops, safety guards and other protective devices, providing dependable dual-channel monitoring and positively guided safety outputs for demanding automation applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.