Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB E1T 3s 2TLA010030R5000 is a 24 V DC safety expansion relay with four normally open relay outputs and a fixed 3-second off-delay for expanding industrial machine safety circuits.
The ABB E1T 3s 24DC 2TLA010030R5000 is a dedicated safety expansion relay with delayed outputs, designed to increase the number of safe relay outputs available from an existing machine safety relay. Part of the established ABB Jokab Safety E1T range, this module provides four redundant normally open outputs for controlling additional contactors, actuators and hazardous machine functions.
Operating from a 24 V DC supply, the E1T 3s provides 4 NO relay outputs with a fixed 3 s switch-off delay. This delayed release allows selected machine functions to remain energised for a controlled period after a stop command, which can be useful where machinery requires a defined run-down or controlled stopping sequence before power is removed from downstream equipment.
The E1T uses mechanically operated internal relays and a monitoring circuit that enables the primary safety relay to supervise correct operation of the expansion module. Its compact 22.5 mm wide DIN rail housing, two LED indicators and quick-release terminal blocks make it suitable for space-conscious industrial control panels. ABB identifies the legacy E1T 3s 24DC as replaced by the newer Sentry TSR10 24VDC.
The ABB E1T 3s is designed to expand an existing safety relay with four additional outputs while introducing a controlled 3 s switch-off delay. When the primary safety circuit is activated, the E1T's internal relays energise and its normally open outputs can control downstream contactors or other safety-related devices. When a stop signal or power failure occurs, the internal relays drop out after the fixed delay, allowing a defined run-down period before the expanded outputs open.
The internal K1 and K2 relays are mechanically operated and must be monitored through terminals X1 and X2 by the safety relay being expanded. If an output contact sticks closed, the associated monitoring contact cannot return to the required state, preventing a new ready signal from being given to the primary safety relay. This monitored architecture enables the E1T to provide additional delayed outputs while remaining integrated into the overall machine safety function.
Tick the specs you need, then view products that match.
| SIL (up to) | SIL 3 | |
|---|---|---|
| Timing Function | None (instantaneous) | |
| Manufacturer | ABB | |
| Product family | ABB Jokab Safety | |
| Series | E1T | |
| Model | E1T 3s 24DC | |
| Manufacturer part number | 2TLA010030R5000 | |
| Product type | Safety expansion relay | |
| Application | Safety relay output expansion / delayed output | |
| Operational voltage | 24 V DC ±15% | |
| Power consumption | 1.5 W | |
| Relay outputs | 4 NO | |
| Switch-off delay | 3 s | |
| Delay tolerance | ±20% | |
| Connection arrangement | Single or dual channel | |
| Maximum resistive AC switching capacity | 6 A at 250 V AC / 1500 VA | |
| AC-15 switching capacity | 2 A at 240 V AC | |
| Maximum resistive DC switching capacity | 6 A at 24 V DC / 150 W | |
| DC-13 switching capacity | 1 A at 24 V DC | |
| Maximum total switching capacity | 12 A distributed across all contacts | |
| Minimum switching load | 10 mA at 10 V | |
| Contact material | Silver with gold flash | |
| Safety category | Up to Category 4 | |
| Status indication | 2 LED indicators | |
| Mounting | 35 mm DIN rail | |
| Terminal arrangement | Quick-release detachable connector blocks | |
| Width | 22.5 mm | |
| Height | 84 mm | |
| Depth | 120 mm | |
| Net weight | 0.22 kg | |
| Colour | Grey | |
| EAN | 7350024432060 | |
| ABB replacement | Sentry TSR10 24VDC, 2TLA010060R0000 |
The ABB E1T 3s is a safety expansion relay designed to add four normally open delayed outputs to an existing safety relay, enabling additional contactors or machine functions to be controlled by the safety system.
The 2TLA010030R5000 operates from a nominal 24 V DC supply with a specified operational-voltage tolerance of ±15%.
The E1T 3s provides 4 normally open relay outputs for expanding the output capacity of an existing machine safety relay.
This version has a fixed 3 s switch-off delay. The delayed outputs are designed to remain active for the specified period before opening following a stop condition.
A delayed safety output can allow machinery to complete a controlled stopping or run-down sequence before downstream contactors or other equipment are de-energised. The suitability of a delay must be determined by the machine's safety design and risk assessment.
For resistive AC loads, the specified maximum switching capacity is 6 A at 250 V AC / 1500 VA. For resistive DC loads it is 6 A at 24 V DC / 150 W, with a maximum total switching capacity of 12 A distributed across all contacts.
The E1T uses mechanically operated internal relays. Its X1-X2 monitoring circuit is connected to the test or reset circuit of the safety relay being expanded, allowing faults such as a welded output contact to prevent the primary safety relay from receiving a new ready signal.
The E1T is designed for installation on a standard 35 mm DIN rail. Its enclosure measures approximately 84 × 22.5 × 120 mm and uses quick-release detachable terminal blocks.
ABB's replacement table identifies the Sentry TSR10 24VDC, part number 2TLA010060R0000, as the replacement for the legacy E1T 3s 24DC expansion relay.
ABB Jokab Safety E1T expansion relays provide additional monitored safety contacts for industrial machinery, with the 3-second version combining four normally open outputs with a fixed off-delay for applications requiring controlled machine run-down or delayed safety isolation.
We use cookies