Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB BT50 2TLA010033R0000 is a compact 24 V DC safety and expansion relay with 3 NO safety outputs, 1 NC output and supervised internal relays for industrial machinery safeguarding and safety output expansion.
The ABB BT50 24DC 2TLA010033R0000 is a compact safety relay and safety expansion relay from the ABB Jokab Safety range, designed for machinery safeguarding and the expansion of existing safety circuits. It can be used with applications including emergency stops, safety gates, hatches and interlocking switches, as well as providing additional safety outputs where an existing safety controller or relay requires greater switching capacity.
Operating from a nominal 24 V DC supply, the BT50 provides 3 NO safety outputs and 1 NC information output. Its internal K1 and K2 relays are supervised so that both must return to their de-energised state before the module can be activated again, helping detect relay faults and preventing an unsafe restart condition.
The BT50 combines a fast response time, monitored test circuit and positively guided relay architecture with a slim 22.5 mm wide DIN rail housing. When correctly incorporated into a suitable safety system, it supports safety performance up to Category 4, PL e and SIL 3, making it a dependable legacy ABB solution for industrial machine-safety and output-expansion applications.
The ABB BT50 uses two internally supervised relays, K1 and K2, to control its safety outputs. When the required 24 V DC supply is present and the A1–X4 test circuit fulfils the activation condition, both relays energise. The three normally open safety outputs are formed by contacts from K1 and K2 connected internally in series, allowing them to interrupt power to downstream devices that stop or prevent hazardous machine movement.
If the supply is removed, K1 and K2 de-energise. Both relays must successfully return to their de-energised state before another activation can occur, providing internal supervision against certain relay faults. This operating principle allows the BT50 to function either as part of a safety control circuit or as an output expansion module where additional redundant safety contacts are required.
Tick the specs you need, then view products that match.
| SIL (up to) | SIL 3 | |
|---|---|---|
| Timing Function | None (instantaneous) | |
| Auxiliary Contacts | None | |
| Coil / Supply Voltage | 24 V DC | |
| Manufacturer | ABB | |
| Product family | ABB Jokab Safety | |
| Series | BT | |
| Model | BT50 24DC | |
| Manufacturer part number | 2TLA010033R0000 | |
| Product type | Safety relay / expansion relay | |
| Rated control supply voltage | 24 V DC | |
| Operational voltage range | 24 V DC +15% / -25% | |
| Safety outputs | 3 NO | |
| NC output | 1 NC | |
| Safety output terminals | 13–14, 23–24, 33–34 | |
| NC output terminals | 41–42 | |
| Test circuit | A1–X4 | |
| Maximum resistive AC switching capacity | 6 A at 250 V AC / 1500 VA | |
| AC-15 switching capacity | 2 A at 240 V AC | |
| Maximum resistive DC switching capacity | 6 A at 24 V DC / 150 W | |
| DC-13 switching capacity | 1 A at 24 V DC | |
| Maximum total resistive switching capacity | 12 A distributed across all contacts | |
| Minimum switching load | 10 mA at 10 V | |
| External output fuse | 5 A gL/gG | |
| Conditional short-circuit current protection | 6 A gG at 1 kA | |
| Maximum input wire resistance at nominal voltage | 200 Ω | |
| Deactivation response time | <20 ms for Version B | |
| Maximum safety category | Category 4 | |
| Maximum Performance Level | PL e | |
| Maximum Safety Integrity Level | SIL 3 | |
| PFHD | 1.22 × 10-8 | |
| Mounting | 35 mm DIN rail | |
| Electrical connection | Screw terminals / detachable connector blocks | |
| Maximum terminal torque | 1 Nm | |
| Single-strand terminal capacity | up to 2 × 1.5 mm² | |
| Enclosure protection | IP40 | |
| Terminal protection | IP20 | |
| Impulse withstand voltage | 2.5 kV | |
| Pollution degree | 2 | |
| Operating temperature | -10 to +55 °C | |
| Operating humidity | 35–85%, without icing or condensation | |
| LED indication | Electrical supply, relay and X4 | |
| Dimensions (H × W × D) | 84 × 22.5 × 120 mm | |
| Net weight | 0.20 kg | |
| EAN | 7350024431841 | |
| ABB replacement | Sentry BSR10 24VDC, 2TLA010040R0000 |
The ABB BT50 is a safety relay and expansion relay suitable for applications including emergency stops, safety gates, hatches, interlocking switches and safety output expansion.
The BT50 2TLA010033R0000 has a nominal 24 V DC supply, with ABB specifying an operational voltage tolerance of +15% / -25%.
The BT50 provides 3 normally open safety outputs and 1 normally closed output. The three NO safety output terminal pairs are 13–14, 23–24 and 33–34.
Yes. ABB describes the BT50 as a safety relay / expansion relay, making it suitable for adding redundant relay outputs to an existing safety-control system.
When correctly integrated into an appropriately designed and validated safety system, the BT50 supports performance up to Category 4 and PL e according to EN ISO 13849-1, and SIL 3 according to EN 62061.
The specified maximum resistive switching capacity is 6 A at 250 V AC / 1500 VA or 6 A at 24 V DC / 150 W, with a maximum total resistive load of 12 A distributed across all contacts.
The BT50 uses internal relays K1 and K2. Both must return to their de-energised state before they can be activated again, while the A1–X4 test circuit forms part of the activation and supervision arrangement.
The BT50 is designed for installation on a standard 35 mm DIN rail. Its compact enclosure measures approximately 84 × 22.5 × 120 mm and uses detachable connection blocks.
ABB identifies the Sentry BSR10 24VDC, part number 2TLA010040R0000, as the replacement for the legacy BT50 24DC safety relay.
ABB Jokab Safety BT50 safety relays provide supervised redundant contacts for industrial machinery safeguarding, combining compact DIN rail construction, three normally open safety outputs and flexible use as either a safety relay or an output expansion module.