ABB 2TLA020072R0400 20-072-04 URAX-C1R is an IP67 AS-i safe input slave with two safe inputs for dual-channel potential-free contacts and an input for local reset.
£238.88
The ABB 2TLA020072R0400, type 20-072-04 / URAX-C1R, is an AS-i safe input slave within the ABB Safety PLC product group. It provides two safe inputs for safety devices with dual-channel contacts together with a dedicated input for local reset, enabling conventional machine-safety devices to be integrated into an AS-Interface safety system.
The URAX-C1R is designed for safety devices with two potential-free contacts in NO+NO or NO+NC configurations. This makes it suitable for devices such as emergency-stop push-buttons and electromechanical safety switches where redundant contact channels must be monitored by the safety system.
Powered directly from the AS-i yellow cable, the module operates from a nominal 30 V DC AS-i supply and consumes less than 150 mA. Its compact yellow-and-black enclosure provides IP67 protection, while the local-reset functionality makes the URAX-C1R particularly useful for decentralised safety installations where a reset device is required close to the protected machine area.
Dual-channel emergency stops and safety switches use redundant contacts so that the safety-control system can detect faults that could otherwise prevent a protective function from operating correctly. The ABB URAX-C1R provides the interface required to connect these devices to an AS-i safety network, accepting safety devices with either NO+NO or NO+NC potential-free contacts.
The additional local reset input allows a reset device to be incorporated close to the machine or guarded area where required by the safety design. Combined with its direct AS-i supply, 12 ms module reaction time and IP67 enclosure, the URAX-C1R provides a compact decentralised interface for safety applications up to PL e / Category 4 and SIL 3 when the complete safety function is appropriately designed and validated.
Tick the specs you need, then view products that match.
| Device Type | Accessory | |
|---|---|---|
| SIL (up to) | SIL 3 | |
| Product group | Safety PLC | |
| Type | 20-072-04 | |
| Product designation | URAX-C1R safe input | |
| ABB order code | 2TLA020072R0400 | |
| Product main type | URAX | |
| Product type | AS-i safe input slave | |
| Safe inputs | 2 for devices with dual-channel contacts | |
| Compatible contact configurations | NO+NO or NO+NC | |
| Contact type | Potential-free contacts | |
| Local reset input | Yes | |
| AS-i profile | S-0.B.0 | |
| Addressing | Jack plug | |
| Supply | AS-i yellow cable | |
| Nominal supply voltage | 30 V DC | |
| Supply-voltage range | 26.5–31.6 V DC | |
| Total AS-i current consumption | <150 mA | |
| Reaction time, off | 12 ms excluding sensors and other peripheral components | |
| Safety integrity | SIL 3 | |
| Performance Level | PL e | |
| Safety category | Category 4 | |
| Enclosure protection | IP67 | |
| Ambient operating temperature | -25 to +65 °C | |
| Colour | Yellow and black | |
| Dimensions (H × W × D) | 96 × 60 × 25 mm | |
| Weight | 150 g |
The ABB 2TLA020072R0400 is an AS-i safe input slave for connecting safety devices with two potential-free contacts to an AS-i safety system, with an additional input for local reset.
The URAX-C1R provides two safe inputs for safety devices with dual-channel contacts.
The module supports safety devices with NO+NO or NO+NC potential-free contacts, including compatible emergency-stop push-buttons and safety switches.
Both models provide safe inputs for dual-channel contact devices, but the URAX-C1R additionally provides an input for local reset.
The ABB order code is 2TLA020072R0400, with the product identified as type 20-072-04 URAX-C1R safe input in the ABB Safety PLC product group.
ABB URAX-C1R provides a robust interface between dual-channel safety contacts and AS-i safety networks, combining safe input monitoring with local reset capability for flexible decentralised machine-safety installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.