2TLA020072R0300 ABB 20-072-03 URAX-C1 Safe Input

2TLA020072R0300 ABB 20-072-03 URAX-C1 Safe Input

ABB 2TLA020072R0300 20-072-03 URAX-C1 is an IP67 AS-i safe input slave with two safe inputs for safety devices using dual-channel NO+NO or NO+NC potential-free contacts.

SKU: 2TLA020072R0300Alt SKU: 20-072-03MPN: 2TLA020072R0300
Price
List Price £247.15 ex VAT
Your Price (ex VAT) Save 15%
£210.08 15% OFF
You save £37.07 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £210.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£210.08

Why Choose the ABB 2TLA020072R0300 URAX-C1 Safe Input?

The ABB 2TLA020072R0300, type 20-072-03 / URAX-C1, is a safe input slave for AS-i bus within the ABB Safety PLC product group. It provides two safe inputs for safety devices with dual-channel contacts, enabling conventional electromechanical safety devices to be integrated into an AS-Interface safety system.

The URAX-C1 is designed for safety devices with two potential-free contacts in either NO+NO or NO+NC configurations. Typical compatible devices include emergency-stop push-buttons and safety switches such as ABB Smile and MKey products, making the module a practical interface between conventional dual-channel safety contacts and an AS-i safety network.

Designed for decentralised industrial machine-safety installations, the URAX-C1 is powered directly from the AS-i yellow cable at 30 V DC and requires less than 150 mA. Its compact yellow-and-black enclosure provides IP67 protection and operates from -25 to +65 °C, supporting installation close to safety devices on machinery and automated equipment.

Key Advantages

  • Safe AS-i input slave for dual-channel safety devices.
  • Provides two safe inputs for devices with potential-free contacts.
  • Supports NO+NO and NO+NC contact configurations.
  • Suitable for emergency-stop buttons, safety switches and other compatible dual-channel devices.
  • Compatible with safety devices such as ABB Smile and MKey.
  • Powered directly from the AS-i yellow cable without a separate auxiliary supply.
  • IP67 enclosure protection supports decentralised machine installation.
  • Safety capability up to PL e / Category 4 and SIL 3 when correctly incorporated into the safety system.

Key Features

  • ABB Safety PLC product group.
  • URAX-C1 model designation.
  • 20-072-03 type designation.
  • ABB order code 2TLA020072R0300.
  • AS-i safe input slave.
  • 2 safe inputs for devices with dual-channel contacts.
  • Supports safety devices with NO+NO or NO+NC potential-free contacts.
  • AS-i profile S-0.B.0.
  • Slave address at delivery: 0.
  • 30 V DC AS-i supply.
  • Reaction time of 12 ms, excluding sensors and other peripheral components.
  • IP67 enclosure protection.
  • Compact yellow-and-black industrial housing.

Reliable Dual-Channel Safety Device Integration with AS-i

Many conventional machine-safety devices use two potential-free contacts to provide redundant switching channels. The ABB URAX-C1 provides the interface required to connect these dual-channel devices to an AS-i safety network, supporting both NO+NO and NO+NC contact arrangements and allowing devices such as emergency stops and guard switches to be incorporated into the safety-control architecture.

With its 12 ms off reaction time, direct AS-i power supply and IP67 enclosure, the URAX-C1 is well suited to decentralised machine installations. Its safety characteristics support applications up to PL e / Category 4 and SIL 3 when the complete safety function is correctly designed, configured and validated.

Typical Applications

  • ABB Pluto AS-i Safety PLC installations.
  • AS-Interface Safety at Work systems.
  • Dual-channel emergency-stop push-buttons.
  • Safety switches with potential-free contacts.
  • ABB Smile emergency-stop devices.
  • ABB MKey safety switches.
  • Machine guard and access-point monitoring.
  • Conveyor and material-handling machinery.
  • Automated production and processing equipment.
  • OEM machine building and functional-safety systems.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Accessory
SIL (up to) SIL 3
Product group Safety PLC
Type 20-072-03
ABB order code 2TLA020072R0300
EAN 7320500410721
Product main type URAX
Product name AS-i Safe input slave
Safe inputs 2 for devices with dual-channel contacts
Compatible contact configurations NO+NO or NO+NC
Compatible device type Safety devices with two potential-free contacts
Typical devices Emergency-stop buttons and safety switches, including Smile and MKey
AS-i profile S-0.B.0
Addressing Jack plug
Supply AS-i yellow cable
Supply voltage 30 V DC
Supply-voltage range 26.5–31.6 V DC
Total AS-i current consumption <150 mA
Reaction time, off 12 ms excluding sensors and other peripheral components
Safety integrity SIL 3
Performance Level Up to PL e
Safety category Category 4 according to ISO 13849-1
Diagnostic coverage High
Enclosure protection IP67
Ambient operating temperature -25 to +65 °C
Colour Yellow and black
Product net width 60 mm
Product net height 96 mm
Product net depth 32 mm
Product net weight 0.18 kg
ETIM classification EC001584 – I/O device for bus system

Frequently Asked Questions

What is the ABB 2TLA020072R0300 URAX-C1 used for?

The ABB 2TLA020072R0300 is an AS-i safe input slave designed to connect safety devices with dual-channel potential-free contacts to an AS-Interface safety system.

How many safe inputs does the URAX-C1 have?

The URAX-C1 provides two safe inputs for safety devices with dual-channel contacts.

Which contact configurations can the ABB URAX-C1 accept?

The URAX-C1 is designed for safety devices using NO+NO or NO+NC potential-free contacts, including compatible emergency-stop buttons and safety switches.

Does the URAX-C1 require a separate 24 V auxiliary supply?

No. The URAX-C1 is powered from the AS-i yellow cable, with a nominal AS-i supply of 30 V DC and an operating range of 26.5–31.6 V DC.

What is the ABB order code for the URAX-C1 safe input?

The ABB order code is 2TLA020072R0300, with the product identified as type 20-072-03 URAX-C1 safe input in the ABB Safety PLC product group.

Designed for ABB AS-i Machine Safety Systems

ABB URAX-C1 provides a robust interface between conventional dual-channel safety contacts and AS-i safety networks, enabling emergency stops, guard switches and other compatible safety devices to be integrated into decentralised machine-safety systems.