Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 2TLA020072R0300 20-072-03 URAX-C1 is an IP67 AS-i safe input slave with two safe inputs for safety devices using dual-channel NO+NO or NO+NC potential-free contacts.
£210.08
The ABB 2TLA020072R0300, type 20-072-03 / URAX-C1, is a safe input slave for AS-i bus within the ABB Safety PLC product group. It provides two safe inputs for safety devices with dual-channel contacts, enabling conventional electromechanical safety devices to be integrated into an AS-Interface safety system.
The URAX-C1 is designed for safety devices with two potential-free contacts in either NO+NO or NO+NC configurations. Typical compatible devices include emergency-stop push-buttons and safety switches such as ABB Smile and MKey products, making the module a practical interface between conventional dual-channel safety contacts and an AS-i safety network.
Designed for decentralised industrial machine-safety installations, the URAX-C1 is powered directly from the AS-i yellow cable at 30 V DC and requires less than 150 mA. Its compact yellow-and-black enclosure provides IP67 protection and operates from -25 to +65 °C, supporting installation close to safety devices on machinery and automated equipment.
Many conventional machine-safety devices use two potential-free contacts to provide redundant switching channels. The ABB URAX-C1 provides the interface required to connect these dual-channel devices to an AS-i safety network, supporting both NO+NO and NO+NC contact arrangements and allowing devices such as emergency stops and guard switches to be incorporated into the safety-control architecture.
With its 12 ms off reaction time, direct AS-i power supply and IP67 enclosure, the URAX-C1 is well suited to decentralised machine installations. Its safety characteristics support applications up to PL e / Category 4 and SIL 3 when the complete safety function is correctly designed, configured and validated.
Tick the specs you need, then view products that match.
| Device Type | Accessory | |
|---|---|---|
| SIL (up to) | SIL 3 | |
| Product group | Safety PLC | |
| Type | 20-072-03 | |
| ABB order code | 2TLA020072R0300 | |
| EAN | 7320500410721 | |
| Product main type | URAX | |
| Product name | AS-i Safe input slave | |
| Safe inputs | 2 for devices with dual-channel contacts | |
| Compatible contact configurations | NO+NO or NO+NC | |
| Compatible device type | Safety devices with two potential-free contacts | |
| Typical devices | Emergency-stop buttons and safety switches, including Smile and MKey | |
| AS-i profile | S-0.B.0 | |
| Addressing | Jack plug | |
| Supply | AS-i yellow cable | |
| Supply voltage | 30 V DC | |
| Supply-voltage range | 26.5–31.6 V DC | |
| Total AS-i current consumption | <150 mA | |
| Reaction time, off | 12 ms excluding sensors and other peripheral components | |
| Safety integrity | SIL 3 | |
| Performance Level | Up to PL e | |
| Safety category | Category 4 according to ISO 13849-1 | |
| Diagnostic coverage | High | |
| Enclosure protection | IP67 | |
| Ambient operating temperature | -25 to +65 °C | |
| Colour | Yellow and black | |
| Product net width | 60 mm | |
| Product net height | 96 mm | |
| Product net depth | 32 mm | |
| Product net weight | 0.18 kg | |
| ETIM classification | EC001584 – I/O device for bus system |
The ABB 2TLA020072R0300 is an AS-i safe input slave designed to connect safety devices with dual-channel potential-free contacts to an AS-Interface safety system.
The URAX-C1 provides two safe inputs for safety devices with dual-channel contacts.
The URAX-C1 is designed for safety devices using NO+NO or NO+NC potential-free contacts, including compatible emergency-stop buttons and safety switches.
No. The URAX-C1 is powered from the AS-i yellow cable, with a nominal AS-i supply of 30 V DC and an operating range of 26.5–31.6 V DC.
The ABB order code is 2TLA020072R0300, with the product identified as type 20-072-03 URAX-C1 safe input in the ABB Safety PLC product group.
ABB URAX-C1 provides a robust interface between conventional dual-channel safety contacts and AS-i safety networks, enabling emergency stops, guard switches and other compatible safety devices to be integrated into decentralised machine-safety systems.