Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 2TLA020071R8100 GATE-C2 is a 24 V DC DIN-rail Pluto gateway providing bidirectional communication between the ABB Pluto Safety Bus and CANopen industrial networks.
£350.80
The ABB 2TLA020071R8100, designated GATE-C2, is a dedicated Pluto Gateway for CANopen designed to provide two-way communication between the ABB Pluto Safety Bus and CANopen networks. Identified by ABB reference 20-071-81 and classified within the Safety PLC product group, it enables Pluto safety controllers to exchange information with supervisory PLCs and other compatible CANopen control systems.
The GATE-C2 incorporates electrically isolated Pluto Safety Bus CAN and CANopen CAN interfaces. Pluto Safety Bus communication supports automatic speed detection from 100 to 1000 kbit/s, while the CANopen interface supports multiple configurable communication rates from 10 to 1000 kbit/s. CANopen addressing can be configured using DIP switches or software, providing flexibility during commissioning and system integration.
Operating from a nominal 24 V DC supply, the GATE-C2 has a slim 22.5 mm module width and mounts on standard 35 mm DIN rail. Included terminal connections are provided for the Pluto Safety Bus, CANopen network and power supply, while front-panel LED indications provide convenient monitoring of Pluto Safety Bus and CANopen communication status.
The ABB GATE-C2 enables information to pass between an ABB Pluto network and a CANopen supervisory control system, allowing Pluto controllers to operate as part of a broader machine-automation architecture. Through CANopen, compatible supervisory systems can access Pluto I/O and other variables, while non-safety-related information can also be transmitted from the supervisory system to the Pluto network.
The gateway shares the established Pluto system interface and can be serviced and configured using ABB Pluto Manager where required. In addition to its gateway function, the GATE-C2 can also be used as an extension of the Pluto Safety Bus cable, providing additional flexibility when designing larger distributed Pluto installations.
Tick the specs you need, then view products that match.
| Safety Functions | Guard / gate monitoring | |
|---|---|---|
| Product Series | ABB Jokab Pluto | |
| Device Type | Programmable safety controller | |
| Output Type | Relay contacts | |
| Communication | CANopen | |
| Product group | Safety PLC | |
| Order code | 2TLA020071R8100 | |
| Reference | 20-071-81 | |
| Product type | Pluto CANopen gateway | |
| Gateway function | Two-way Pluto Safety Bus / CANopen communication | |
| Pluto interface | Isolated Pluto Safety Bus CAN | |
| Fieldbus interface | Isolated CANopen CAN | |
| Pluto Safety Bus speeds | 100, 200, 250, 400, 500, 800 and 1000 kbit/s | |
| Pluto bus speed selection | Automatic detection | |
| CANopen speeds via DIP switch | 125, 250 and 500 kbit/s | |
| CANopen speeds via software | 10, 20, 50, 100, 125, 250, 500, 800 and 1000 kbit/s | |
| CANopen address range | 1–63 | |
| CANopen address setting | DIP switches or software | |
| CANopen specification | CiA Draft Standard 301 Version 4.02 | |
| Operating voltage | 24 V DC, -15% to +20% | |
| Current consumption | <100 mA at 24 V DC | |
| Pluto Safety Bus connection | Top 3-pole terminal | |
| CANopen connection | Front 5-pole terminal | |
| Power connection | Bottom 2-pole terminal | |
| Status indication | Pluto Safety Bus and CANopen LEDs | |
| Protection rating | IP20 | |
| Installation | 35 mm DIN rail | |
| Operating ambient temperature | -10 to +55 °C | |
| Transport and storage temperature | -25 to +55 °C | |
| Dimensions (W × H × D) | 22.5 × 101 × 119 mm | |
| Product net weight | approx. 0.12 kg | |
| UPC | 7320500410653 |
The ABB 2TLA020071R8100 GATE-C2 provides two-way communication between the ABB Pluto Safety Bus and a CANopen network, allowing Pluto controllers to exchange data with compatible supervisory control systems.
The GATE-C2 is specifically designed for CANopen and incorporates isolated CAN interfaces for both the CANopen network and Pluto Safety Bus.
The Pluto Safety Bus supports 100–1000 kbit/s with automatic speed detection. CANopen supports selectable speeds from 10 to 1000 kbit/s through software, with 125, 250 and 500 kbit/s also selectable using DIP switches.
The GATE-C2 operates from a nominal 24 V DC supply, with an operating range of -15% to +20% around the nominal voltage.
The gateway is designed for installation on standard 35 mm DIN rail inside an industrial control panel and has a compact module width of approximately 22.5 mm.
ABB GATE-C2 Pluto gateways provide a practical interface between Pluto safety-controller networks and CANopen automation systems, enabling bidirectional data exchange and straightforward integration into larger industrial control architectures.