Pizzato ST GD230N5-P11 ST G series 24 V DC RFID safety sensor with two IS1–IS2 safety inputs, two OS1–OS2 safety outputs, one O3 signalling output and an integrated PVC cable for industrial machine guard monitoring.
£213.09
The Pizzato ST GD230N5-P11 is a compact RFID non-contact safety sensor from the Pizzato ST G series, designed for reliable monitoring of movable guards, safety doors and access points on industrial machinery. Its RFID operating principle provides coded guard detection without mechanical contact, helping minimise wear while delivering dependable switching for frequently operated machine safety applications.
The GD230 architecture incorporates two safety inputs IS1–IS2, two safety outputs OS1–OS2 and one O3 signalling output. This combination enables the sensor to participate in compatible interconnected safety architectures, including series-connected arrangements used to simplify wiring on machinery with multiple monitored guards.
Operating from a 24 V DC supply, the ST GD230N5-P11 uses an N5 integrated PVC cable for direct machine wiring. The compact glass-fibre reinforced technopolymer housing, multicolour status indication and IP67 / IP69K protection provide a robust solution for demanding machine guarding, safety interlocking and industrial automation installations.
RFID safety sensors such as the Pizzato ST GD230N5-P11 monitor movable machine guards without requiring mechanical engagement between the sensor and actuator. The electronic sensing system evaluates the associated RFID actuator and communicates the resulting guard condition through the redundant OS1–OS2 safety outputs to a compatible safety module or safety PLC with OSSD inputs.
The GD230 architecture also incorporates IS1–IS2 safety inputs, enabling the sensor to participate in compatible series-connected safety circuits. Multiple ST series sensors can be interconnected to simplify safety-system wiring, while the dedicated O3 signalling output provides additional status information for machine control and diagnostics. When correctly integrated, ST series architectures can maintain safety performance up to PL e.
Tick the specs you need, then view products that match.
| Cable Length (m) | 5 m | |
|---|---|---|
| Sensing Principle | RFID (coded) | |
| Contacts | 2 safety outputs (OSSD) + 1 signalling | |
| Supplied As | Sensor only | |
| Connection | Integrated cable | |
| Product Series | Pizzato ST G (RFID) | |
| IP Rating | IP67, IP69K | |
| Manufacturer | Pizzato Elettrica | |
| Series | ST G RFID Safety Sensor Series | |
| Model | ST GD230N5-P11 | |
| Alternative SKU | STGD230N5P11 | |
| Product type | RFID non-contact electronic safety sensor | |
| Detection technology | RFID | |
| Supply voltage | 24 V DC | |
| Safety inputs | 2 × IS1–IS2 | |
| Safety outputs | 2 × OS1–OS2 | |
| Signalling output | 1 × O3 | |
| Connection type | Integrated PVC cable | |
| Cable configuration | N5 | |
| Product configuration | P11 | |
| Housing | Glass-fibre reinforced self-extinguishing technopolymer | |
| Safety capability | Up to PL e, Category 4 and SIL 3 when correctly integrated | |
| Protection rating | IP67 according to EN 60529 / IP69K according to ISO 20653 | |
| Operating principle | RFID non-contact guard detection | |
| Status indication | Multicolour RGB LED | |
| Application | Machine guarding, safety interlocking and industrial automation | |
| Barcode | 8018851606199 | |
| HS Code | 85369095 |
The ST GD230N5-P11 is designed for RFID non-contact monitoring of machine guards, safety doors and access points in industrial safety interlocking and automation systems.
The sensor provides two safety inputs IS1–IS2, two safety outputs OS1–OS2 and one O3 signalling output for integration into compatible industrial machine safety systems.
The N5 configuration uses an integrated PVC cable, providing direct electrical connection between the safety sensor and the machine safety or automation system.
Yes. Its IS1–IS2 safety inputs and OS1–OS2 safety outputs allow it to participate in compatible series-connected ST safety architectures, helping simplify wiring on machinery with multiple monitored guards.
Yes. The ST G series provides IP67 protection according to EN 60529 and IP69K protection according to ISO 20653, making it suitable for demanding industrial machine safety applications.
Pizzato ST G RFID safety sensors provide machine builders and automation engineers with compact non-contact guard monitoring, flexible series connectivity and robust electronic safety switching for modern industrial machinery and automated production systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.