2TLA022044R0500 ABB Mute R2 Retroreflective Photoelectric Sensor

2TLA022044R0500 ABB Mute R2 Retroreflective Photoelectric Sensor

ABB Mute R2 2TLA022044R0500 is an IP67/IP69K retroreflective PNP photoelectric sensor with polarising filters, adjustable sensitivity and a 0.1–5 m typical sensing range for muting applications with ABB Orion light guards.

SKU: 2TLA022044R0500Alt SKU: MUTE R2 SENSORMPN: 2TLA022044R0500
Price
List Price £156.08 ex VAT
Your Price (ex VAT) Save 10%
£140.47 10% OFF
You save £15.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £140.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£140.47

Why Choose the ABB Mute R2 2TLA022044R0500 Retroreflective Photoelectric Sensor?

The ABB Mute R2 2TLA022044R0500 is a retroreflective photoelectric sensor designed primarily for use as a muting sensor with ABB Orion light guards. As part of the ABB Light Guards, Beams and Scanners product group, it provides reliable object detection for automated muting applications where material needs to pass through an active protective field without unnecessarily stopping the machine.

The Mute R2 uses a visible 660 nm red light source with polarising filters and operates with a reflector positioned opposite the sensor. It provides a PNP open-collector output, selectable Light-on or Dark-on operation and sensitivity adjustment via an integrated trimmer. Depending on the ABB reflector used, the typical operating distance extends from 0.1 to 5 m.

Designed for demanding industrial environments, the Mute R2 features a robust M18 threaded plastic housing with IP67 and IP69K protection. A male M12 4-pole connector provides straightforward field connection, while a fast 1 ms response time and 500 Hz switching frequency support responsive detection in machine-safety muting installations.

Key Advantages

  • Purpose-designed muting sensor for ABB Orion light guards.
  • Retroreflective photoelectric sensing with polarising filters.
  • Typical sensing distance up to 5 m with the appropriate ABB reflector.
  • Fast 1 ms response time for responsive object detection.
  • PNP open-collector output with overload and short-circuit protection.
  • Selectable Light-on or Dark-on operating modes.
  • Adjustable sensitivity enables optimisation for the installation.
  • IP67 and IP69K protection for demanding industrial environments.

Key Features

  • ABB Mute R2 retroreflective photoelectric sensor.
  • ABB order code 2TLA022044R0500.
  • Designed for muting applications with Orion light guards.
  • 12–30 V DC operating supply range.
  • PNP open-collector output.
  • Maximum output current of 100 mA.
  • 1 ms response time.
  • 500 Hz switching frequency.
  • Visible red 660 nm emission.
  • Mono-turn sensitivity adjustment trimmer.
  • Selectable Dark-on / Light-on operation.
  • M18 × 1 threaded housing for convenient sensor mounting.
  • M12 4-pole male connector, compatible with an M12 5-pole female connector.
  • IP67 / IP69K mechanical protection.

Retroreflective Sensing for Light Guard Muting

Muting allows a safety light guard to be temporarily and automatically bypassed under defined conditions, typically so authorised material can enter or leave a hazardous area without stopping the production process. Sensors such as the ABB Mute R2 detect the material and provide the signals required by the muting system to determine when the protective function may be temporarily suspended.

The Mute R2 uses a retroreflective operating principle in which the sensor emits light towards a reflector and monitors the returned beam. Interruption of this beam changes the sensor output. Polarising filters help improve reliable differentiation of the reflector, while adjustable sensitivity, Light-on/Dark-on selection and ABB reflector options provide flexibility when commissioning the sensor for different machine layouts.

Typical Applications

  • Muting applications with ABB Orion light guards.
  • Pallet entry and exit monitoring.
  • Conveyor-based material transfer systems.
  • Automated production and assembly lines.
  • Packaging and palletising machinery.
  • Material handling and logistics equipment.
  • Robot cell material entry and exit points.
  • Industrial object detection applications requiring retroreflective sensing.
  • OEM machine-safety and automation installations.

Technical Specifications

Tick the specs you need, then view products that match.

IP Rating IP67
Device Type Muting sensor / accessory
Product group Light guards, beams, scanners
ABB order code 2TLA022044R0500
GTIN 7350024483147
Product type Retroreflective photoelectric sensor / muting sensor
Primary application Muting sensor for ABB Orion light guards
Sensing principle Retroreflective with polarising filters
Supply voltage 12–30 V DC
Maximum ripple 2 Vpp
Current consumption Maximum 30 mA, excluding output current
Output PNP open collector
Maximum output current 100 mA
Maximum output saturation voltage 2 V
Response time 1 ms
Switching frequency 500 Hz
Operating mode Selectable Light-on / Dark-on
Sensitivity adjustment Mono-turn trimmer
Emission type Red light, 660 nm
Operating distance with Reflect 1 Typically 0.1–4 m
Operating distance with Reflect 2 Typically 0.1–5 m
Reflect 1 63 mm diameter reflector, ABB order code 2TLA022044R2000
Reflect 2 82 mm diameter reflector, ABB order code 2TLA022044R3000
Connection M12 4-pole male connector
Housing M18 × 1 threaded plastic housing
Housing material ABS
Lens material PMMA
Protection rating IP67 / IP69K
Operating temperature -25 to +55 °C
Storage temperature -25 to +70 °C
Ambient light rejection According to EN 60947-5-2

Frequently Asked Questions

What is the ABB Mute R2 2TLA022044R0500 used for?

The Mute R2 is a retroreflective photoelectric sensor designed primarily for muting applications with ABB Orion light guards, detecting objects or materials as part of an appropriately configured muting system.

What is the sensing range of the ABB Mute R2?

The typical operating distance is 0.1–4 m with the ABB Reflect 1 reflector and 0.1–5 m with the larger Reflect 2 reflector.

What electrical output does the Mute R2 provide?

The Mute R2 provides a PNP open-collector output with overload and short-circuit protection and a maximum output current of 100 mA.

Which reflectors can be used with the Mute R2?

ABB specifies the Reflect 1 63 mm reflector, order code 2TLA022044R2000, and the Reflect 2 82 mm reflector, order code 2TLA022044R3000. The larger reflector provides a typical operating distance of up to 5 m.

Is the ABB Mute R2 suitable for demanding industrial environments?

Yes. The sensor has an IP67 and IP69K protection rating, an operating temperature range of -25 to +55 °C and a robust M18 threaded housing for industrial installation.

Reliable Optical Sensing for ABB Machine Safety Systems

ABB Mute R2 provides robust retroreflective object detection for Orion light guard muting applications, combining fast PNP switching, adjustable sensitivity and IP67/IP69K environmental protection in a compact M18 sensor format.