ABB EPX-PA412 1SKV580240S0001 is a 400 A, 12-way Protecta Power pan assembly designed for internal power distribution within compatible ABB low-voltage MCCB panelboard systems.
£3,685.02
The ABB EPX-PA412, manufacturer order code 1SKV580240S0001, is a 400 A, 12-way pan assembly designed for the ABB Protecta Power low-voltage electrical distribution system. It provides the designated internal power distribution assembly for compatible Protecta Power panelboard configurations, supporting the arrangement of outgoing moulded case circuit breaker (MCCB) circuits.
With a specified 400 A current rating and 12 outgoing ways, the EPX-PA412 is intended for distribution applications requiring a coordinated internal assembly within the Protecta Power enclosure system. It is particularly relevant to electrical panel builders and contractors assembling or maintaining compatible ABB Protecta Power 400 A panelboards.
The EPX-PA412 is supplied as a pan assembly component rather than a complete enclosed panelboard. This distinction allows the correct internal assembly to be identified separately from the enclosure, incoming protective equipment, outgoing MCCBs and other installation accessories required for the finished distribution board.
The ABB Protecta Power system is designed for low-voltage distribution applications using outgoing MCCB arrangements. Its panelboard range includes different current ratings and outgoing way configurations, allowing electrical designers to select a suitable assembly for the required distribution capacity and circuit layout.
The EPX-PA412 provides the 400 A, 12-way pan assembly option. Within the same product family, ABB also identifies the EPX-PA408 as a 400 A, 8-way pan assembly and the EPX-PA418 as a 400 A, 18-way pan assembly. Corresponding 800 A variants include the EPX-PA808, EPX-PA812 and EPX-PA818. These distinct models allow selection according to the required current rating and number of outgoing ways.
The associated EPX-PB412 complete panelboard configuration is specified with a 400 A busbar rating, 12 outgoing ways and enclosure dimensions of 1700 × 1000 × 300 mm. These are the dimensions of the associated panelboard enclosure, not the standalone physical dimensions of the EPX-PA412 pan assembly.
When assembling a Protecta Power distribution board, the pan assembly must be matched with the correct enclosure, incoming device, outgoing circuit breakers and other required accessories. Electrical designers should verify the complete assembly's short-circuit withstand capability, protective device coordination, cable connections and applicable installation requirements. The 400 A rating identifies the specified pan assembly capacity and does not mean that every outgoing circuit is individually rated at 400 A.
Tick the specs you need, then view products that match.
| Metering | No metering | |
|---|---|---|
| Product Series | ABB Protecta Power | |
| Device Type | Distribution Board | |
| Number of Outgoing Ways | 12 | |
| Current | 400 A | |
| Product family | Protecta Power Enclosures | |
| Series | ABB Protecta Power | |
| ABB order code | 1SKV580240S0001 | |
| Manufacturer description | EPX-PA412 Pan Assembly 400A - 12 Ways | |
| Product type | Electrical distribution pan assembly | |
| Rated current | 400 A | |
| Number of outgoing ways | 12 | |
| Associated panelboard family | ABB Protecta Power | |
| Associated panelboard configuration | 400 A, 12-way | |
| Associated complete panelboard model | EPX-PB412 | |
| Associated panelboard enclosure dimensions (H × W × D) | 1700 × 1000 × 300 mm | |
| Primary function | Internal power distribution assembly for outgoing circuits | |
| Installation arrangement | Within a compatible Protecta Power panelboard enclosure | |
| Application | Low-voltage MCCB distribution systems | |
| Product classification | Panelboard internal assembly component | |
| Manufacturer product group | Protecta Power Enclosures |
The ABB EPX-PA412 is a 400 A, 12-way pan assembly designed for compatible ABB Protecta Power electrical distribution panelboards. It forms part of the internal distribution arrangement supporting outgoing circuits.
The EPX-PA412 has a specified current rating of 400 A. The rating applies to the pan assembly and should not be interpreted as the individual rating of every outgoing circuit breaker position.
The EPX-PA412 provides 12 outgoing ways within its designated Protecta Power distribution configuration. The selection and arrangement of outgoing MCCBs must follow ABB's applicable assembly requirements.
The EPX-PA412 corresponds to the 400 A, 12-way Protecta Power configuration associated with the EPX-PB412 panelboard. The EPX-PB412 enclosure is specified at 1700 mm high × 1000 mm wide × 300 mm deep; these are not the standalone dimensions of the pan assembly.
No. The EPX-PA412 is a pan assembly component, not a complete enclosed distribution board. The finished installation requires the appropriate compatible enclosure, incoming equipment, outgoing protective devices and any other specified accessories.
ABB Protecta Power provides a coordinated range of low-voltage panelboards, pan assemblies, moulded case circuit breakers and installation accessories for commercial and industrial electrical distribution. The ABB EPX-PA412 offers a dedicated 400 A, 12-way internal distribution assembly for compatible Protecta Power panelboard configurations, supporting structured and professional switchboard construction.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.