ABB EPP-1004R is a 100 A four-pole 30 mA Type AC RCD incoming connection kit with left-side neutral for compatible ABB Protecta Plus distribution boards.
£252.66
The ABB EPP-1004R, ABB order code 1TVS151800S2563, is a 100 A four-pole RCD incoming connection kit designed for ABB Protecta Plus distribution boards. As part of the ABB Protecta Plus Distribution Board range, it provides incoming residual current protection and isolation for compatible three-phase and neutral electrical distribution installations.
The EPP-1004R incorporates a 30 mA Type AC RCD with a left-side neutral configuration, providing residual current protection at the incoming side of the distribution board. It is supplied as a coordinated incoming kit, helping installers configure compatible Protecta Plus boards using components specifically designed for the ABB distribution system.
With a rated current of 100 A and a four-pole configuration, the EPP-1004R is suitable for Protecta Plus applications requiring three-phase and neutral residual current protection. The kit includes the incoming device, copper connection kit and fittings, cover plate and instruction leaflet for straightforward integration into the compatible distribution board.
An RCD monitors the balance of current flowing through the live conductors and disconnects the electrical supply when residual current above its operating threshold is detected. The ABB EPP-1004R combines this protective function with the incoming arrangement required for compatible Protecta Plus distribution boards, providing a coordinated solution for installations requiring 30 mA residual current protection.
The ABB Protecta Plus range is designed as a flexible low-voltage distribution platform with dedicated incoming, metering, surge protection and other accessory kits. Using the EPP-1004R allows installers to configure a compatible Protecta Plus board with a purpose-designed 100 A four-pole RCD incomer while maintaining the integrated arrangement of the distribution system.
Tick the specs you need, then view products that match.
| Device Type | Incomer / Metering / Surge Kit | |
|---|---|---|
| Current | 100 A | |
| Incomer | RCCB | |
| Product Series | ABB Protecta Plus | |
| Series | Protecta Plus Distribution Board | |
| ABB order code | 1TVS151800S2563 | |
| Product type | RCD incoming connection kit | |
| Rated current | 100 A | |
| Number of poles | 4 | |
| RCD type | Type AC | |
| Rated residual operating current | 30 mA | |
| Neutral position | Left-side neutral | |
| For use with | ABB Protecta Plus distribution boards | |
| Kit contents | Copper connection kit and fittings, incoming device, cover plate and instruction leaflet |
The EPP-1004R is a 100 A four-pole RCD incoming connection kit designed to provide incoming residual current protection for compatible ABB Protecta Plus distribution boards.
The ABB EPP-1004R has a rated current of 100 A.
The incoming RCD has a rated residual operating current of 30 mA.
The EPP-1004R uses a Type AC four-pole RCD with a left-side neutral configuration.
The kit includes the copper connection kit and fittings, incoming RCD device, cover plate and instruction leaflet.
ABB Protecta Plus distribution equipment provides a flexible platform for low-voltage electrical distribution, with dedicated incoming kits such as the EPP-1004R enabling coordinated residual current protection and straightforward integration into compatible distribution boards.