nx2-14dsl-rh1 chint dual rcd split load consumer unit fitted with miniture circuit breakers

nx2-14dsl-rh1 chint dual rcd split load consumer unit fitted with miniture circuit breakers

Chint NX2-14DSL-RH1 14 way dual RCD split load consumer unit supplied complete with fitted protective devices for domestic and light commercial electrical installations.

SKU: NX2-14DSL-RH1Alt SKU: NX214DSLRH1MPN: NX2-14DSL-RH1
Price
List Price £208.82 ex VAT
Your Price (ex VAT) Save 55%
£93.97 55% OFF
You save £114.85 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £93.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£93.97

Why Choose the Chint NX2-14DSL-RH1 Dual RCD Split Load Consumer Unit?

The Chint NX2-14DSL-RH1 is a high-quality 14 way dual RCD split load consumer unit supplied pre-configured with protective devices, providing a practical and reliable solution for domestic and light commercial electrical installations. Designed to simplify installation, it offers organised final circuit distribution with enhanced electrical safety through dual residual current protection.

As part of the proven Chint NX2 consumer unit range, the NX2-14DSL-RH1 provides a robust enclosure for modular protective devices while supporting safe circuit segregation across two RCD-protected sections. This helps minimise disruption by ensuring that not all circuits are disconnected if a single RCD trips.

With a 14 way split load configuration, this consumer unit is ideal for new installations, property refurbishments and electrical upgrades where dependable circuit protection, straightforward installation and compliance with current wiring practices are required.

Key Advantages

  • 14 way dual RCD split load consumer unit.
  • Supplied complete with fitted protective devices.
  • Dual RCD arrangement improves circuit segregation.
  • Suitable for domestic and light commercial installations.
  • DIN rail design accepts modular protective devices.
  • Provides organised and reliable final circuit distribution.

Key Features

  • Chint NX2 Series consumer unit.
  • 14 usable ways.
  • Dual RCD split load configuration.
  • Supplied complete with factory-fitted protective devices.
  • DIN rail mounted modular design.
  • Integrated neutral and earth terminal bars.
  • Wall-mounted enclosure.
  • Suitable for 230V AC low voltage installations.

Reliable Distribution for Modern Electrical Installations

The Chint NX2-14DSL-RH1 provides a practical solution for distributing final circuits while improving electrical safety through dual RCD protection. Its split load arrangement helps reduce inconvenience by separating circuits across two protected sections, allowing unaffected circuits to remain energised if one RCD operates.

The pre-configured design helps reduce installation time while providing a tidy and organised consumer unit suitable for residential properties, apartments, offices and other light commercial applications.

Typical Applications

  • Domestic consumer unit installations.
  • New build residential properties.
  • Property refurbishment projects.
  • Small commercial premises.
  • Final circuit distribution.
  • Electrical upgrades and rewires.

Technical Specifications

Tick the specs you need, then view products that match.

Current 100 A
Product Series Chint NX
Device Type Distribution Board
Incomer RCCB
Number of Outgoing Ways 14
Manufacturer Chint
Series NX2
Model NX2-14DSL-RH1
Product type Dual RCD split load consumer unit
Configuration Factory assembled consumer unit
Number of ways 14 Way
Protection type Dual RCD split load
Rated voltage 230V AC
Rated current Up to 100A
Frequency 50 / 60Hz
Mounting type Wall mounted
Device mounting DIN rail
Application Final circuit distribution
Standard IEC/EN 61439-3

Frequently Asked Questions

What is the Chint NX2-14DSL-RH1 used for?

It is used as a dual RCD split load consumer unit for distributing and protecting final electrical circuits in residential and light commercial installations.

How many ways does this consumer unit provide?

The NX2-14DSL-RH1 is a 14 way consumer unit.

What does the dual RCD split load design offer?

The split load arrangement separates circuits across two RCDs, helping minimise disruption by preventing all protected circuits from disconnecting during a single fault.

Is this consumer unit supplied complete?

Yes. The NX2-14DSL-RH1 is supplied as a factory assembled consumer unit fitted with protective devices.

Where is this consumer unit typically installed?

It is commonly installed in domestic properties, apartments, offices and other light commercial electrical installations.

Trusted by Electrical Professionals Worldwide

Chint NX2 consumer units are trusted by electricians, contractors and panel builders for reliable circuit protection, straightforward installation and dependable performance in modern low voltage electrical installations.