ABB EPH-S66112 Protecta Home 12-way steel consumer unit featuring a factory-fitted 63 A incoming RCCB, shrouded busbar, neutral and earth bars, and a RAL 7035 enclosure measuring 250 x 330 x 105 mm for residential and light commercial electrical distribution.
£144.97
The ABB EPH-S66112 is a 12-way, 63 A RCCB-controlled consumer unit from the ABB Protecta Home range, designed for residential and light commercial electrical distribution. Featuring a 63 A residual current circuit breaker (RCCB) as its incoming protective device, this consumer unit combines residual current protection with a practical arrangement for distributing electricity to multiple outgoing circuits.
With 12 outgoing circuit ways, the EPH-S66112 provides a versatile distribution solution for installations requiring a single RCCB-protected circuit group. Its incoming RCCB monitors residual current imbalance and disconnects the associated circuits when its specified operating conditions are met, supporting electrical safety when installed as part of a correctly designed protection system.
Housed in a durable steel enclosure measuring 250 × 330 × 105 mm, the ABB EPH-S66112 offers additional circuit capacity compared with smaller Protecta Home consumer units. The assembly is supplied with its specified factory-fitted RCCB, shrouded busbar, neutral and earth bars, and installation instructions, providing a convenient foundation for professional electrical distribution installations.
The ABB EPH-S66112 is designed for electrical installations requiring a consumer unit with a single incoming residual current protective device and sufficient space for multiple outgoing circuits. Its 12-way configuration provides capacity for compatible miniature circuit breakers and other approved modular protective devices, allowing electricians to organise lighting, socket outlet and fixed appliance circuits according to the installation design.
The consumer unit incorporates a 63 A RCCB as its incoming protective device. Unlike a main switch-only consumer unit, this arrangement provides residual current protection for the outgoing circuits connected through the RCCB. The device monitors the balance between outgoing and returning current and disconnects the protected circuits when a qualifying residual current imbalance occurs.
The 63 A rating describes the current-carrying capacity of the RCCB and must not be confused with its residual current operating sensitivity. The precise residual current sensitivity, RCCB type and operating characteristics should be confirmed from the installed protective device specification and matched to the electrical installation requirements.
Because the EPH-S66112 uses a single RCCB-controlled arrangement, a residual current fault on one outgoing circuit may cause the incoming RCCB to disconnect all circuits supplied through it. This shared protection arrangement should be considered when assessing circuit grouping, continuity of supply and the suitability of the consumer unit for a particular installation.
Importantly, an RCCB does not independently provide overload or short-circuit protection. Appropriate miniature circuit breakers or other compatible overcurrent protective devices must therefore be selected for the outgoing circuits. Suitable upstream overcurrent protection must also be provided for the RCCB in accordance with the installation design and ABB instructions.
The incoming RCCB may provide switching and isolation functionality where the installed device is approved and suitable for that purpose. However, the EPH-S66112 is an RCCB-controlled consumer unit rather than a separate 63 A main switch plus RCCB configuration. This distinction is important when comparing different ABB Protecta Home models.
The steel enclosure provides robust housing for the electrical distribution assembly. Its nominal dimensions of 250 × 330 × 105 mm, RAL 7035 finish, shrouded busbar and conductor termination bars provide an organised platform for professional installation.
Final protective device selection, conductor sizing, earthing arrangements, circuit coordination and installation methods must comply with ABB instructions and applicable electrical installation regulations, including relevant BS 7671 requirements.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Device Type | Consumer Unit | |
| Incomer | RCCB | |
| Number of Outgoing Ways | 12 | |
| Current | 63 A | |
| Product range | Protecta Home | |
| Manufacturer description | EPH-S66112 12W 63A RCCB | |
| Product type | RCCB-controlled consumer unit | |
| ABB order code | 1TVS151800S3054 | |
| Product group | Protecta Home | |
| Number of outgoing ways | 12 | |
| Outgoing modular capacity | 12 modules | |
| Incoming protective device | Residual current circuit breaker (RCCB) | |
| Incoming RCCB rated current | 63 A | |
| Number of incoming RCCBs | 1 | |
| Residual current protection groups | 1 | |
| Consumer unit configuration | Single RCCB-controlled distribution | |
| Enclosure material | Steel | |
| Enclosure colour | Light grey | |
| RAL colour code | RAL 7035 | |
| Nominal height | 250 mm | |
| Nominal width | 330 mm | |
| Nominal depth | 105 mm | |
| Nominal dimensions (H × W × D) | 250 × 330 × 105 mm | |
| Factory-fitted RCCB | Included | |
| Shrouded busbar | Included | |
| Neutral bar | Included | |
| Protective earth bar | Included | |
| Installation instructions | Included | |
| Consumer unit assembly standard | BS EN 61439-3 | |
| Application | Residential and light commercial electrical distribution | |
| Outgoing circuit protection | Compatible protective devices selected according to installation requirements | |
| Manufacturer product family | Protecta Home steel consumer units |
The ABB EPH-S66112 is a 12-way Protecta Home consumer unit featuring a 63 A incoming RCCB. It is designed for residential and light commercial electrical distribution installations requiring a single RCCB-protected circuit group.
The EPH-S66112 provides 12 outgoing circuit ways for compatible modular protective devices. The outgoing circuits are supplied through the consumer unit's 63 A RCCB-controlled arrangement.
Yes. The EPH-S66112 is specified with a factory-fitted 63 A residual current circuit breaker. The RCCB provides residual current protection for its associated outgoing circuits, while suitable overcurrent protective devices must be selected separately.
The ABB EPH-S66112 has nominal dimensions of 250 × 330 × 105 mm (height × width × depth). It features a steel enclosure with a RAL 7035 light grey finish.
The EPH-S66112 incorporates a 63 A RCCB as its incoming protective device, providing residual current protection for the associated outgoing circuits. A 12-way main switch-only consumer unit instead uses a switch disconnector for incoming isolation and does not provide the same built-in RCCB protection.
ABB Protecta Home consumer units provide practical electrical distribution solutions through robust steel enclosures, integrated protective equipment and organised modular circuit arrangements. The EPH-S66112 combines 12 outgoing ways with a 63 A incoming RCCB in a durable steel enclosure, supporting professional residential and light commercial electrical installations.