Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPH-SURGE-M (1TVC151800S3299) is a Protecta Home MMP275 Type 2 surge protection device with a manufacturer-stated 10 kA surge rating, designed to help limit transient overvoltages in suitable low-voltage electrical distribution installations.
£146.03
The ABB EPH-SURGE-M (1TVC151800S3299) is a Type 2 surge protection device (SPD) from the ABB Protecta Home product group, identified by the manufacturer as MMP275 Type 2 SPD 10kA. Designed for integration into suitable low-voltage electrical distribution installations, this surge protective device helps limit transient overvoltages that could otherwise damage connected electrical and electronic equipment.
Transient overvoltages can occur as a result of lightning-related disturbances, electrical switching operations and other events affecting the electricity supply. The ABB EPH-SURGE-M provides a dedicated surge protection solution for appropriately configured consumer units and distribution assemblies. Its Type 2 classification makes it relevant to installations requiring protection against transient overvoltages within the electrical distribution system.
With a manufacturer-stated 10 kA surge current rating and MMP275 designation, the EPH-SURGE-M is a practical choice for electrical contractors specifying surge protection within the ABB Protecta Home range. Correct selection, installation and coordination with the electrical supply and upstream protective devices are essential to achieving the intended level of protection.
A Type 2 surge protection device is designed to limit transient overvoltages within an electrical installation. Such disturbances can arise from indirect lightning effects and switching events on the electrical network. When correctly selected and installed, an SPD helps divert surge current through an appropriate protective path and limit the voltage experienced by downstream equipment.
The ABB EPH-SURGE-M is identified as an MMP275 Type 2 SPD rated at 10 kA. The 10 kA value is a surge current rating and must not be interpreted as the device's continuous load current or the fault current rating of a circuit breaker. Surge protection datasheets distinguish between parameters such as nominal discharge current (In), maximum discharge current (Imax) and impulse current (Iimp). The precise meaning of the 10 kA rating should therefore be checked against ABB's product-specific technical documentation before final specification.
For effective protection, the SPD must be suitable for the installation's supply voltage, earthing arrangement and prospective fault conditions. The installer must also consider backup overcurrent protection, conductor routing, connection lengths and coordination with any other surge protection devices. These factors influence the performance of the completed surge protection system.
Importantly, a Type 2 SPD does not replace an MCB, RCBO, RCCB or main switch. Each device performs a different protective function. Surge protection should be considered as part of the wider electrical installation design, with the requirements of BS 7671 and the manufacturer's instructions used to determine the appropriate arrangement.
Tick the specs you need, then view products that match.
| Device Type | Incomer / Metering / Surge Kit | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Product group | Protecta Home | |
| Product model | EPH-SURGE-M | |
| ABB order code | 1TVC151800S3299 | |
| Manufacturer description | EPH-SURGE-M MMP275 Type 2 SPD 10kA | |
| Product type | Surge protection device (SPD) | |
| Product category | Low-voltage surge protection accessories | |
| SPD designation | MMP275 | |
| SPD classification | Type 2 | |
| Manufacturer-stated surge current rating | 10 kA | |
| Primary protective function | Limitation of transient overvoltages | |
| Protection application | Low-voltage electrical distribution | |
| Product range association | ABB Protecta Home | |
| Applicable installation requirements | BS 7671 and ABB installation instructions | |
| Surge current parameter | The manufacturer's description states 10 kA; the exact parameter designation must be verified against the product datasheet | |
| Maximum continuous operating voltage (Uc) | Confirm from the product-specific technical documentation | |
| Voltage protection level (Up) | Confirm from the product-specific technical documentation | |
| Number of poles | Confirm from the product-specific technical documentation | |
| Mounting and connection arrangement | Confirm from ABB's installation instructions | |
| Backup overcurrent protection | Select according to ABB's requirements and the installation design | |
| Compatible earthing systems | Confirm suitability for the intended supply arrangement | |
| Typical use | Surge protection within appropriately configured electrical distribution assemblies |
The ABB EPH-SURGE-M is a Type 2 surge protection device designed to help limit transient overvoltages in suitable low-voltage electrical distribution installations. It is part of the ABB Protecta Home product group.
The official ABB order code is 1TVC151800S3299. The product model is EPH-SURGE-M, with the manufacturer description EPH-SURGE-M MMP275 Type 2 SPD 10kA.
The EPH-SURGE-M is classified as a Type 2 surge protection device (SPD). Type 2 SPDs are used to limit transient overvoltages in appropriately designed electrical distribution systems.
The 10 kA figure is the surge current rating stated in ABB's product description. It does not represent the normal continuous load current. The exact surge current parameter, such as In or Imax, should be confirmed from the product-specific datasheet.
MMP275 is the device designation included in ABB's description of the EPH-SURGE-M. The complete model-specific technical documentation should be consulted to confirm its voltage characteristics and other electrical ratings.
The EPH-SURGE-M belongs to ABB's Protecta Home product group and is intended for suitable electrical distribution surge protection applications. Compatibility with a particular consumer unit, mounting arrangement and supply configuration must be confirmed before installation.
The EPH-SURGE-M is specified as a Type 2 SPD, which is primarily intended to limit transient overvoltages associated with indirect lightning effects and switching events. Installations requiring direct lightning current handling may need an appropriately selected Type 1 or combined Type 1+2 SPD.
No. A surge protection device limits transient overvoltages, while MCBs and other overcurrent protective devices protect against overloads and short circuits, and RCDs provide residual current protection. The EPH-SURGE-M does not replace these devices.
Suitability depends on the supply voltage, earthing system, installation conditions and required protection arrangement. The relevant ABB technical documentation must be checked to confirm compatibility before specifying or installing the device.
The EPH-SURGE-M (1TVC151800S3299) is described as an MMP275 Type 2 SPD 10 kA, while the EPH-SURGE (1TVC151800S3208) is listed as an MMP275 Type 2 SPD 6 kA. The manufacturer descriptions identify different surge current ratings; the precise rating parameters should be verified using the corresponding datasheets.
The ABB EPH-SURGE-M Type 2 Surge Protection Device offers a dedicated solution for limiting transient overvoltages within suitable low-voltage electrical distribution installations. Identified by ABB as the MMP275 Type 2 SPD 10 kA, it complements the Protecta Home range and supports professional electrical installations where correctly specified surge protection is required.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.