Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPH-S11108 Protecta Home 8-way steel consumer unit featuring a factory-fitted 100 A incoming RCCB, shrouded busbar, neutral and earth bars, and a RAL 7035 enclosure measuring 250 x 270 x 105 mm for residential and light commercial electrical distribution.
£157.10
The ABB EPH-S11108 is an 8-way, 100 A RCCB-controlled consumer unit from the ABB Protecta Home range, designed for residential and light commercial electrical distribution. Featuring a 100 A residual current circuit breaker (RCCB) as its incoming protective device, this consumer unit provides residual current protection and switching for its associated outgoing circuits.
Designed to accommodate 8 outgoing circuit ways, the EPH-S11108 provides a compact and practical distribution solution for installations requiring a single RCCB-protected circuit group. The 100 A RCCB monitors residual current imbalance and disconnects the protected circuits when its specified operating conditions are met, supporting electrical safety when installed as part of a correctly designed protection system.
Housed in a durable steel enclosure with nominal dimensions of 250 × 270 × 105 mm, the ABB EPH-S11108 combines compact construction with practical circuit organisation. Supplied with the specified factory-fitted RCCB, shrouded busbar, neutral and earth bars, and installation instructions, it provides a convenient platform for professional electrical distribution board assembly.
The ABB EPH-S11108 is designed for electrical installations requiring a compact distribution board with a single incoming residual current protective device. Its 8-way configuration provides space for compatible miniature circuit breakers and other approved modular protection devices, allowing electrical contractors to arrange outgoing circuits according to the installation design.
The consumer unit incorporates a 100 A RCCB as its incoming device. Unlike a main switch-only consumer unit, this configuration provides residual current protection for the outgoing circuits connected through the RCCB. The device monitors the balance between outgoing and returning current and disconnects the protected circuits when a qualifying residual current imbalance is detected.
The 100 A rating describes the current-carrying capacity of the RCCB and should not be confused with its residual current operating sensitivity. The precise residual current sensitivity and RCCB type must be confirmed from the installed device specification and matched to the electrical installation requirements.
Because the EPH-S11108 uses a single RCCB-controlled arrangement, a residual current fault on one outgoing circuit may cause the RCCB to disconnect all circuits supplied through it. Electrical designers should consider this shared protection arrangement when determining circuit allocation and continuity-of-supply requirements.
Importantly, an RCCB does not independently provide overload or short-circuit protection. Appropriate miniature circuit breakers or other compatible overcurrent protective devices must therefore be selected for the outgoing circuits. The incoming RCCB must also have suitable upstream overcurrent protection in accordance with the electrical design and manufacturer instructions.
The RCCB can provide switching and isolation functionality where the installed device is approved and suitable for that purpose. However, the EPH-S11108 is an RCCB-controlled consumer unit rather than a separate 100 A main switch plus RCCB configuration. This distinction is important when selecting the correct ABB Protecta Home model.
The steel enclosure provides a robust housing for the distribution assembly, while its compact 250 × 270 × 105 mm dimensions support practical installation planning. The RAL 7035 finish, factory-fitted RCCB, shrouded busbar and termination bars help provide an organised foundation for a professionally assembled consumer unit.
Final device selection, conductor sizing, earthing arrangements, residual current protection coordination and installation methods must comply with ABB installation instructions and applicable electrical installation regulations, including relevant BS 7671 requirements.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Device Type | Consumer Unit | |
| Incomer | RCCB | |
| Number of Outgoing Ways | 8 | |
| Current | 100 A | |
| Product range | Protecta Home | |
| Manufacturer description | EPH-S11108 8W 100A RCCB | |
| Product type | RCCB-controlled consumer unit | |
| ABB order code | 1TVC151800S3100 | |
| Product group | Protecta Home | |
| Number of outgoing ways | 8 | |
| Outgoing modular capacity | 8 modules | |
| Incoming protective device | Residual current circuit breaker (RCCB) | |
| Incoming RCCB rated current | 100 A | |
| Number of incoming RCCBs | 1 | |
| Residual current protection groups | 1 | |
| Consumer unit configuration | Single RCCB-controlled distribution | |
| Enclosure material | Steel | |
| Enclosure colour | Light grey | |
| RAL colour code | RAL 7035 | |
| Nominal height | 250 mm | |
| Nominal width | 270 mm | |
| Nominal depth | 105 mm | |
| Nominal dimensions (H × W × D) | 250 × 270 × 105 mm | |
| Factory-fitted RCCB | Included | |
| Shrouded busbar | Included | |
| Neutral bar | Included | |
| Protective earth bar | Included | |
| Installation instructions | Included | |
| Consumer unit assembly standard | BS EN 61439-3 | |
| Application | Residential and light commercial electrical distribution | |
| Outgoing circuit protection | Compatible protective devices selected separately according to installation requirements | |
| Manufacturer product family | Protecta Home steel consumer units |
The ABB EPH-S11108 is an 8-way Protecta Home consumer unit featuring a 100 A incoming RCCB. It is designed for residential and light commercial electrical distribution installations requiring a single RCCB-protected circuit group.
The EPH-S11108 provides 8 outgoing circuit ways for compatible modular protective devices. The outgoing circuits are supplied through the consumer unit's 100 A RCCB-controlled arrangement.
Yes. The EPH-S11108 is specified with a factory-fitted 100 A residual current circuit breaker. The RCCB provides residual current protection for its associated outgoing circuits, while suitable overcurrent protective devices must be selected separately.
The ABB EPH-S11108 has nominal dimensions of 250 × 270 × 105 mm (height × width × depth). It features a steel enclosure with a RAL 7035 light grey finish.
The EPH-S11108 incorporates a 100 A RCCB as its incoming protective device, providing residual current protection for the associated outgoing circuits. An 8-way main switch-only consumer unit instead uses a switch disconnector for incoming isolation and does not provide the same built-in RCCB protection.
ABB Protecta Home consumer units provide practical electrical distribution solutions through robust steel enclosures, integrated protective equipment and organised modular circuit arrangements. The EPH-S11108 combines 8 outgoing ways with a 100 A incoming RCCB in a compact steel enclosure, supporting professional residential and light commercial electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.