Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPH-S66219-AF Protecta Home 19-way AFDD-compatible split-load consumer unit featuring a 63 A main switch isolator, two 63 A RCCBs and a 38-module steel enclosure for domestic electrical distribution.
£366.64
The ABB EPH-S66219-AF is a robust and versatile 19-way split-load consumer unit designed for MCB and Arc Fault Detection Device (AFDD) installations in domestic and residential electrical distribution systems. As part of the established ABB Protecta Home series, this consumer unit incorporates a 63 A main switch isolator and two 63 A residual current circuit breakers (RCCBs), providing a practical arrangement for circuit isolation and residual current protection.
Designed to accommodate modern electrical protection requirements, the EPH-S66219-AF provides space for suitable miniature circuit breakers (MCBs) and arc fault detection devices, allowing electricians to configure outgoing circuits according to installation requirements. Its split-load configuration separates circuits into RCCB-protected groups, while its AFDD-compatible layout supports the use of additional arc fault protection where required.
With 19 outgoing ways, a 63 A main isolator and two 63 A RCCBs, the EPH-S66219-AF is suitable for residential installations requiring organised electrical distribution and flexible protective device selection. Its 38-module capacity and nominal dimensions of 500 × 450 × 105 mm (H × W × D) provide the additional installation space required for MCB and AFDD arrangements within a durable steel enclosure.
Modern domestic electrical installations require effective circuit protection, reliable isolation and sufficient space for protective devices. The ABB EPH-S66219-AF Protecta Home consumer unit provides a practical distribution solution by combining a 63 A main switch isolator with two 63 A RCCBs and an enclosure arrangement designed to accommodate suitable MCBs and AFDDs.
The two RCCBs provide residual current protection for their respective groups of outgoing circuits. These devices monitor the balance between live and neutral currents and disconnect the protected circuits when a residual current fault exceeds the device's operating threshold. This helps reduce the risk of electric shock and certain electrical fault hazards when the installation is correctly designed and maintained. RCCBs do not provide overload or short-circuit protection independently, so suitable overcurrent protective devices must be installed.
The AFDD-compatible design allows electricians to incorporate appropriate arc fault detection devices into the distribution system. AFDDs are designed to detect characteristic electrical arcing faults that may not be identified by conventional overcurrent or residual current protective devices. When correctly selected and installed, they provide an additional level of protection against electrical fire risks associated with dangerous arcing conditions. The EPH-S66219-AF is designed to accommodate AFDDs; individual AFDD devices must be selected separately according to the circuit requirements.
The 38-module enclosure capacity provides the space required for wider protective devices, while the robust steel construction, shrouded busbar and integrated terminal bars support organised installation and maintenance. As part of the ABB Protecta Home range, this consumer unit offers a dependable platform for residential electrical distribution systems requiring flexible circuit protection arrangements.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Device Type | Consumer Unit | |
| Incomer | Main switch / isolator + 2× RCCB + AFDD | |
| Number of Outgoing Ways | 19 | |
| Module Capacity | 38 modules | |
| Current | 63 A | |
| Product Series | ABB Protecta Home | |
| Series | Protecta Home | |
| ABB order code | 1TVC151800S3089 | |
| Product type | AFDD-compatible split-load consumer unit | |
| Distribution type | Low-voltage domestic electrical distribution | |
| Number of ways | 19 | |
| Module capacity | 38 modules | |
| Main switch type | Switch isolator | |
| Main switch rated current | 63 A | |
| Residual current protection | 2 × RCCB | |
| RCCB 1 rated current | 63 A | |
| RCCB 2 rated current | 63 A | |
| Load arrangement | Split load | |
| Protective device compatibility | Suitable MCBs and AFDDs | |
| Enclosure material | Steel | |
| Enclosure colour | RAL 7035 | |
| Nominal height | 500 mm | |
| Nominal width | 450 mm | |
| Nominal depth | 105 mm | |
| Dimensions (H × W × D) | 500 × 450 × 105 mm | |
| Internal distribution | Shrouded busbar | |
| Terminal arrangement | Earth and neutral terminal bars | |
| Applicable standard | BS EN 61439-3 | |
| Application | Domestic and residential electrical distribution |
The ABB EPH-S66219-AF is a 19-way split-load consumer unit designed for domestic electrical distribution. It incorporates a 63 A main switch and two 63 A RCCBs and provides an AFDD-compatible arrangement for suitable outgoing circuit protective devices.
The EPH-S66219-AF provides 19 outgoing ways with a total capacity of 38 modules. This arrangement provides space for suitable MCBs and wider protective devices such as AFDDs.
The consumer unit incorporates a 63 A main switch isolator, providing a central means of isolating the incoming electrical supply to the distribution board.
The EPH-S66219-AF includes two 63 A residual current circuit breakers (RCCBs). These provide residual current protection for separate groups of outgoing circuits within the split-load arrangement.
Yes. The EPH-S66219-AF is an AFDD-compatible consumer unit designed to accommodate suitable arc fault detection devices. AFDDs provide additional protection by detecting dangerous electrical arcing faults that may create fire risks. Compatible devices must be selected according to the installation requirements.
The EPH-S66219-AF is an AFDD-compatible consumer unit supplied with a factory-fitted main switch and RCCBs. The AFDD designation identifies the enclosure arrangement and does not establish that individual AFDD protective devices are included. Suitable outgoing protective devices should be specified separately.
The consumer unit has nominal dimensions of 500 mm high, 450 mm wide and 105 mm deep. Its steel enclosure provides space for the 38-module protective device arrangement.
The included RCCBs provide residual current protection but do not independently provide overload or short-circuit protection. Suitable MCBs, RCBOs or other correctly selected protective devices must be installed to provide the required overcurrent protection for outgoing circuits.
Yes. The ABB Protecta Home EPH-S66219-AF is designed for domestic and residential electrical distribution applications. The installation must be designed, assembled and verified by a competent electrician in accordance with applicable electrical installation standards and manufacturer instructions.
ABB Protecta Home consumer units provide professional electricians and electrical contractors with practical solutions for residential power distribution, combining durable steel enclosures, flexible circuit arrangements and compatibility with modern protective devices to support reliable domestic electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.