Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPH-S17208 Protecta Home eight-way dual-RCD split-load consumer unit with 100 A main switch isolator, one 80 A RCCB and one 63 A RCCB. Nominal dimensions 250 × 330 × 105 mm. ABB order code 1TVC151800S3070.
£231.49
The ABB EPH-S17208 (ABB order code 1TVC151800S3070) is an 8-way, 100 A split-load consumer unit from the ABB Protecta Home range. Designed for low-voltage electrical distribution, this consumer unit combines a 100 A main switch isolator with two residual current devices (RCDs), rated at 80 A and 63 A respectively. This configuration provides a practical solution for suitable residential electrical installations requiring two RCD-protected circuit groups.
Identified by ABB as EPH-S17208 8W 100A ISO 1x80A+63A RC, the unit provides eight outgoing ways within a coordinated split-load arrangement. The two RCDs allow outgoing circuits to be divided between separately protected sections, with the exact allocation determined by the approved consumer unit configuration and installation requirements.
The EPH-S17208 features nominal enclosure dimensions of 250 × 330 × 105 mm (H × W × D), as listed in ABB's Protecta Home consumer unit selection guide. The compact format makes it suitable for installations where eight outgoing ways are sufficient and a larger distribution board would be unnecessary.
With a 100 A incoming isolator, an 80 A RCCB and a 63 A RCCB, the ABB EPH-S17208 offers a defined dual-RCD configuration for professional electrical installers. The main switch provides incoming isolation, while the RCCBs provide residual current protection to their associated outgoing circuit groups. Appropriate overcurrent protection must be provided separately for the final circuits.
The ABB EPH-S17208 is designed around a specific combination of electrical devices: a 100 A incoming isolator, an 80 A RCCB and a 63 A RCCB. This differs from Protecta Home consumer units fitted with two identically rated RCCBs and provides an alternative arrangement for projects requiring the manufacturer's mixed-rating dual-RCD configuration.
The 100 A main switch provides the incoming isolation function for the consumer unit. It is used to disconnect the supply to the assembly when appropriate. The switch's rated current must not be confused with the permissible load of the individual outgoing circuits or the rated current of either RCCB.
The 80 A RCCB provides residual current protection for one section of the consumer unit. Its 80 A rating represents the device's rated current-carrying capacity, subject to its installation conditions and coordination. It does not describe the amount of earth leakage required to operate the device.
The 63 A RCCB provides corresponding residual current protection for the other section. The two RCCBs have different rated currents, so the installer must ensure that the proposed circuit allocation, upstream protection and expected loading are appropriate for each device.
ABB's Protecta Home selection guide notes that RCCB split consumer units have a variable split arrangement. The precise allocation of the eight outgoing ways between the two RCCBs should therefore be confirmed against the supplied assembly and manufacturer's installation instructions rather than assuming a fixed four-way/four-way division.
Although the consumer unit provides two RCD-protected sections, an earth leakage fault on a circuit may disconnect other circuits supplied through the same RCCB. Where a design requires more individualised fault protection or improved continuity of supply, the electrician should consider whether a compatible RCBO-based arrangement is more appropriate.
The RCCBs do not replace outgoing overcurrent protective devices. Suitable MCBs or other approved protective devices must be provided for overload and short-circuit protection. The selected equipment must be compatible with the ABB busbar system, enclosure arrangement and completed assembly specification.
The nominal enclosure dimensions of 250 × 330 × 105 mm should be considered during installation planning. Sufficient space must be allowed for mounting, conductor routing, cable entry, access to protective devices and the safe operation of the main switch and RCCBs.
Installation, inspection and commissioning must be undertaken by a competent electrical professional in accordance with ABB's instructions and applicable requirements of BS 7671. The installer must confirm RCCB sensitivity and type, circuit grouping, neutral conductor separation, device compatibility, earthing arrangements and final electrical test results.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Device Type | Consumer Unit | |
| Incomer | Main switch / isolator + RCCB | |
| Number of Outgoing Ways | 8 | |
| Current | 100 A | |
| Brand | ABB | |
| Product group | Protecta Home | |
| Product range | Protecta Home | |
| ABB order code | 1TVC151800S3070 | |
| Manufacturer designation | EPH-S17208 8W 100A ISO 1x80A+63A RC | |
| Product type | Dual-RCD split-load consumer unit | |
| Consumer unit configuration | Main switch with two RCCBs | |
| Number of outgoing ways | 8 | |
| Incoming isolation device | Main switch isolator | |
| Main switch rated current | 100 A | |
| Number of RCCBs | 2 | |
| First RCCB rated current | 80 A | |
| Second RCCB rated current | 63 A | |
| RCCB arrangement | 1 × 80 A + 1 × 63 A | |
| Number of RCD-protected sections | 2 | |
| Nominal height | 250 mm | |
| Nominal width | 330 mm | |
| Nominal depth | 105 mm | |
| Nominal dimensions (H × W × D) | 250 × 330 × 105 mm | |
| Dimensional reference | ABB Protecta Home consumer unit selection guide | |
| RCCB rated residual operating current (IΔn) | Confirm against the fitted devices and ABB documentation | |
| RCCB type | Confirm against the fitted devices and ABB documentation | |
| RCCB pole configuration | Confirm against the fitted device specification | |
| RCCB current ratings | 80 A and 63 A | |
| Incoming isolation function | Provided by the 100 A main switch | |
| Residual current protection | Provided by the two RCCBs | |
| Outgoing circuit overcurrent protection | Requires suitable compatible protective devices | |
| Outgoing circuit arrangement | Subject to ABB's approved split-load configuration | |
| Split arrangement | Variable, subject to ABB's instructions | |
| Enclosure material | Steel, as specified for the Protecta Home consumer unit family | |
| Enclosure finish | RAL 7035 grey, as specified for the Protecta Home steel enclosure family | |
| Busbar arrangement | Confirm against the supplied assembly and ABB installation instructions | |
| Neutral bar arrangement | Must correspond to the separate RCCB-protected sections | |
| Protective earth bar arrangement | Confirm against the supplied assembly | |
| Ingress protection | Confirm against the exact product documentation | |
| Mechanical impact resistance | Confirm against the exact product documentation | |
| Electrical application | Low-voltage final-circuit distribution | |
| Installation environment | Suitable indoor electrical distribution locations | |
| Relevant assembly standard | BS EN 61439-3, as applicable to the completed assembly | |
| Installation requirements | BS 7671 and ABB manufacturer instructions | |
| Professional installation | Required |
The ABB EPH-S17208 is an eight-way Protecta Home split-load consumer unit with a 100 A main switch isolator, one 80 A RCCB and one 63 A RCCB. It is intended for suitable low-voltage electrical distribution installations.
The ABB manufacturer order code is 1TVC151800S3070. The model designation is EPH-S17208.
The ABB EPH-S17208 provides eight outgoing ways. The distribution of these ways between the two RCCB-protected sections must follow ABB's approved split-load arrangement.
The consumer unit is specified with a 100 A incoming main switch isolator. This provides the incoming isolation function for the assembly.
The ABB EPH-S17208 is specified with two RCCBs: one rated at 80 A and one rated at 63 A.
The designation identifies an eight-way consumer unit with a 100 A main switch isolator, one 80 A RCCB and one 63 A RCCB.
Yes. The EPH-S17208 is a dual-RCD split-load consumer unit designed to accommodate outgoing circuits across two separately RCCB-protected sections.
ABB lists nominal dimensions of 250 × 330 × 105 mm (height × width × depth) for the EPH-S17208 in its Protecta Home consumer unit selection guide.
The EPH-S17208 uses ABB's specified mixed-rating dual-RCCB arrangement. The suitability of each section depends on its expected loading, upstream protection and the approved circuit distribution. The two current ratings do not establish the residual operating sensitivity of either RCCB.
No. 80 A is the RCCB's rated current, not its residual operating sensitivity. The rated residual operating current is expressed in milliamps and must be verified against the fitted device markings.
The main switch and RCCBs do not independently provide outgoing circuit overload or short-circuit protection. Suitable compatible protective devices must be incorporated into the completed electrical installation.
The EPH-S17208 is intended for use with compatible outgoing circuit protective devices. Any MCBs must be suitable for the ABB enclosure and busbar system and correctly selected for their circuits.
ABB notes that its RCCB split consumer units have a variable split arrangement. An equal division should not be assumed without checking the specific supplied assembly and manufacturer's installation instructions.
If one RCCB operates, it disconnects the circuits supplied through its protected section. Circuits supplied through the other RCCB may remain energised, provided no other protective device operates and the installation is correctly arranged.
Both are eight-way Protecta Home consumer units with a 100 A main switch and two RCCBs. The EPH-S17208 has one 80 A and one 63 A RCCB, whereas the EPH-S16208 has two 63 A RCCBs.
Both models specify a 100 A main switch with one 80 A RCCB and one 63 A RCCB. The EPH-S17208 provides eight ways, while the EPH-S17212 provides twelve ways.
The ABB EPH-S17208 Protecta Home consumer unit combines eight outgoing ways with a 100 A incoming isolator, one 80 A RCCB and one 63 A RCCB. With nominal dimensions of 250 × 330 × 105 mm, it provides a compact, coordinated dual-RCD solution for professionally designed residential electrical distribution installations.
We use cookies