ABB EPH-S16218 Protecta Home 18-way dual-RCD split-load consumer unit with 100 A main switch isolator and two 63 A residual current devices. Designed for suitable low-voltage electrical distribution installations. ABB order code 1TVC151800S3069.
£238.51
The ABB EPH-S16218 (ABB order code 1TVC151800S3069) is an 18-way split-load consumer unit from the ABB Protecta Home range. Its specified configuration combines a 100 A main switch isolator with two 63 A residual current devices (RCDs), providing a coordinated distribution arrangement for suitable residential and similar low-voltage electrical installations.
Identified by ABB as EPH-S16218 18W 100A ISO 2x63A RC, this consumer unit offers 18 outgoing ways together with two RCD-protected sections. The arrangement is designed to support the distribution of outgoing circuits across separate residual current protection groups, subject to the approved internal configuration and the requirements of the completed electrical installation.
The 100 A incoming isolator provides a means of disconnecting the consumer unit supply, while the two 63 A RCDs provide residual current protection for their associated circuit groups. The main switch and RCDs perform different electrical functions: the isolator provides switching and isolation, whereas the RCDs respond to residual current imbalance. Suitable overcurrent protection must also be provided for outgoing circuits.
Part of ABB's Protecta Home consumer unit family, the EPH-S16218 is intended for professional electrical distribution assembly and installation. It is a practical choice for projects requiring a relatively high number of outgoing ways and a dual-RCD arrangement rather than a main-switch-only consumer unit.
The ABB EPH-S16218 combines three important configuration elements: 18 outgoing ways, a 100 A main isolator and two 63 A RCDs. These elements determine the basic layout and purpose of the consumer unit, although the detailed allocation of circuit positions must be confirmed from ABB's installation documentation.
The 100 A main switch provides the incoming isolation function. It allows the supply to the consumer unit to be disconnected for appropriate switching and maintenance operations. The 100 A figure is the rated current of the switch; it does not automatically establish the permissible demand of the installation or the rating of individual outgoing circuits.
The two 63 A residual current devices are intended to protect their associated circuit groups against specified residual current conditions. Their 63 A rating is a current-carrying rating, not their residual operating sensitivity. The RCD sensitivity, device type and other performance characteristics must be verified from the actual devices and the manufacturer documentation.
A dual-RCD split-load arrangement allows circuits to be distributed between two residual current protection sections. This can support planned circuit grouping, but it does not guarantee that an earth leakage fault on one circuit will leave all other circuits energised. Circuits sharing the same RCD may be disconnected together if that RCD operates.
The 18 outgoing ways provide flexibility when designing a distribution schedule. Installers should consider the number of circuits, device widths, conductor routing and the exact allocation of ways to each RCD. The manufacturer-approved internal arrangement must be followed, including the separation of neutral conductors associated with different RCD groups.
Because an RCD does not replace an MCB or other overcurrent protective device, outgoing circuits require appropriate overload and short-circuit protection. Protective devices must be selected for the circuit design and confirmed as compatible with the ABB consumer unit and its busbar system.
The electrical design must also consider RCD selection and unwanted tripping. Modern installations may contain equipment with different residual current characteristics, and the suitability of the fitted RCD type should be assessed against the connected loads and applicable standards. Where individual-circuit residual current protection or improved circuit separation is required, an RCBO-based arrangement may be more appropriate.
The EPH-S16218 should be installed, inspected and commissioned by a competent electrical professional in accordance with ABB's instructions and BS 7671. The installer must verify the actual RCD ratings and types, conductor connections, protective device coordination, enclosure suitability and final test results before energising the installation.
Tick the specs you need, then view products that match.
| Current | 100 A | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Device Type | Consumer Unit | |
| Incomer | Main switch / isolator + RCCB | |
| Number of Outgoing Ways | 18 | |
| Brand | ABB | |
| Product group | Protecta Home | |
| Product range | Protecta Home | |
| ABB order code | 1TVC151800S3069 | |
| Manufacturer designation | EPH-S16218 18W 100A ISO 2x63A RC | |
| Product type | Dual-RCD split-load consumer unit | |
| Distribution application | Low-voltage final-circuit distribution | |
| Number of outgoing ways | 18 | |
| Incoming isolation arrangement | Main switch isolator | |
| Main switch rated current | 100 A | |
| Number of RCDs specified | 2 | |
| First RCD rated current | 63 A | |
| Second RCD rated current | 63 A | |
| RCD arrangement | Dual-RCD | |
| Consumer unit configuration | Split-load | |
| Number of RCD-protected groups | 2 | |
| Incoming isolation function | Yes | |
| Residual current protection | Provided by the two specified RCDs | |
| RCD rated residual operating current (IΔn) | Confirm against the fitted RCD markings and ABB documentation | |
| RCD type | Confirm against the fitted RCD markings and ABB documentation | |
| RCD poles | Confirm against the fitted device specification | |
| RCD short-circuit coordination | Subject to the complete assembly and upstream protection | |
| Outgoing circuit overcurrent protection | Requires suitable compatible protective devices | |
| Outgoing device compatibility | Subject to ABB's approved assembly requirements | |
| Distribution of ways between RCD sections | Confirm against the manufacturer's internal arrangement | |
| Enclosure construction | Confirm against the product-specific ABB datasheet | |
| Enclosure finish | Confirm against the product-specific ABB datasheet | |
| Overall height | Confirm against ABB's dimensional drawing | |
| Overall width | Confirm against ABB's dimensional drawing | |
| Overall depth | Confirm against ABB's dimensional drawing | |
| Ingress protection rating | Confirm against the exact enclosure specification | |
| Mechanical impact rating | Confirm against the exact enclosure specification | |
| Busbar arrangement | Confirm against the product-specific assembly documentation | |
| Neutral terminal arrangement | Must be appropriate to the two RCD-protected groups | |
| Protective earth terminal arrangement | Confirm against the supplied assembly | |
| Installation environment | As specified by ABB for the complete enclosure | |
| Applicable installation requirements | BS 7671 and the relevant assembly standards | |
| Installation and commissioning | By a competent electrical professional |
The ABB EPH-S16218 is an 18-way Protecta Home split-load consumer unit with a 100 A main switch isolator and two 63 A RCDs. It is designed for suitable low-voltage electrical distribution installations.
The ABB manufacturer order code is 1TVC151800S3069. The model designation is EPH-S16218.
The ABB EPH-S16218 is an 18-way consumer unit. The exact distribution of those ways between the two RCD-protected sections should be confirmed from ABB's assembly documentation.
The ABB EPH-S16218 is specified with a 100 A incoming main switch isolator. This is the switch's rated current and does not independently determine the allowable loading of each outgoing circuit.
The EPH-S16218 is specified with two RCDs, each having a rated current of 63 A.
The designation identifies an 18-way consumer unit with a 100 A isolator and two 63 A residual current devices. It describes the basic incoming switch and RCD arrangement.
Yes. The EPH-S16218 is a dual-RCD split-load consumer unit designed to distribute outgoing circuits across two RCD-protected sections.
Yes. The specified configuration includes a 100 A main switch isolator as well as the two 63 A RCDs.
No. 63 A is the RCD's rated current, not its residual operating sensitivity. The rated residual operating current, expressed in milliamps, must be checked against the fitted RCD specification.
The 100 A isolator and two RCDs do not independently provide outgoing circuit overload and short-circuit protection. Suitable compatible protective devices must be selected for the completed electrical installation.
The consumer unit is intended for an arrangement of compatible outgoing protective devices. Any MCBs must be suitable for ABB's approved busbar and enclosure configuration and correctly rated for their circuits.
Any proposed RCBO arrangement must be checked against ABB's approved device compatibility and the existing RCD configuration. The presence of two upstream RCDs may affect selectivity and circuit protection design.
If one RCD operates, it will disconnect the circuits supplied through its protected section. Circuits supplied through the other RCD may remain energised, provided no other protective device operates and the installation is correctly arranged.
The exact overall dimensions for 1TVC151800S3069 should be confirmed from ABB's product-specific dimensional drawing. Dimensions from other Protecta Home models should not be substituted when planning the installation.
Both models are 18-way Protecta Home consumer units with a 100 A isolator and two RCDs. The EPH-S16218 has two 63 A RCDs, while the EPH-S11218 is designated with two 100 A RCDs.
Both models specify a 100 A isolator and two 63 A RCDs. The EPH-S16218 provides 18 ways, whereas the EPH-S16216 provides 16 ways.
The ABB EPH-S16218 Protecta Home consumer unit combines 18 outgoing ways with a 100 A incoming isolator and two 63 A RCDs. Its dual-RCD split-load configuration provides a coordinated basis for professionally designed residential electrical distribution installations where separate residual current protection groups are required.