Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPH-S66208 1TVC151800S3062 is an 8-way Protecta Home split-load steel consumer unit featuring a factory-fitted 63 A main switch isolator and two 63 A RCCBs. The RAL 7035 enclosure measures a nominal 250 x 330 x 105 mm and is supplied with a shrouded busbar, neutral and earth bars, and installation instructions. Designed to BS EN 61439-3.
£212.88
The ABB EPH-S66208 Protecta Home Consumer Unit (1TVC151800S3062) is a genuine ABB 8-way split-load consumer unit featuring a 63 A main switch isolator and two 63 A residual current circuit breakers (RCCBs). Designed for professional electrical distribution installations, it provides a compact, coordinated assembly for accommodating compatible outgoing circuit protection devices.
Part of the ABB Protecta Home range, the EPH-S66208 features a durable steel enclosure finished in RAL 7035 light grey. Its adaptable split-load arrangement enables suitable outgoing circuits to be divided between two RCCB-protected sections, subject to the installation design and ABB's assembly instructions.
With nominal dimensions of 250 mm high, 330 mm wide and 105 mm deep, this consumer unit offers a practical solution where installation space is limited. The assembly is supplied with factory-fitted incoming devices, a shrouded busbar, neutral and earth bars, and installation instructions, and is designed to BS EN 61439-3.
The ABB EPH-S66208 combines a 63 A incoming main switch with two 63 A RCCBs, allowing outgoing circuits to be organised into two residual current protection groups.
This arrangement can be useful in domestic electrical installations where circuits are divided between separate RCCB sections. If one RCCB trips, the circuits connected to that section may lose supply while circuits on the other section can remain energised, provided no wider supply interruption has occurred.
ABB identifies its RCCB split-load consumer units as having a variable split arrangement. The actual distribution of outgoing ways must be configured using the approved busbar and terminal arrangement and in accordance with the manufacturer's instructions.
The two 63 A RCCBs do not provide a combined incoming current rating of 126 A. The assembly has a 63 A main switch, and the complete installation must be designed within the applicable equipment and supply ratings.
With nominal dimensions of 250 x 330 x 105 mm, the ABB EPH-S66208 is one of the more compact dual-RCCB configurations in the Protecta Home range. Its eight-way layout makes it suitable for installations requiring a modest number of outgoing circuits while retaining a split-load arrangement.
The RAL 7035 steel enclosure provides a coordinated housing for the factory-fitted switching equipment, residual current devices and compatible outgoing circuit breakers.
Before installation, the electrician should verify the available mounting space, cable entry arrangement, accessibility and any required working clearances. The published dimensions are nominal enclosure dimensions and should not be treated as wall cut-out measurements.
The EPH-S66208 is supplied with the incoming 63 A switch disconnector and two 63 A RCCBs already fitted. ABB also specifies a shrouded busbar, neutral and earth bars, and installation instructions as part of the Protecta Home steel consumer unit assembly.
These components provide a coordinated foundation for the completed electrical distribution board. The neutral terminal arrangement must correspond to the two RCCB-protected circuit groups, while protective earth connections must maintain the required continuity.
Outgoing miniature circuit breakers are not identified as included in the standard EPH-S66208 configuration. They should be selected separately using the approved ABB device range and the requirements of each outgoing circuit.
The ABB EPH-S66208 should be installed by a competent electrical professional in accordance with the applicable wiring regulations, including BS 7671 where relevant, and ABB's product-specific instructions.
Each RCCB-protected circuit must have its line and neutral conductors arranged correctly. Neutrals from different RCCB groups must not be mixed, as incorrect connections can lead to unwanted tripping or improper operation.
RCCBs provide residual current protection but do not independently provide the overload and short-circuit protection required for outgoing circuits. Suitable circuit breakers or other approved protective devices must therefore be selected and installed as part of the completed assembly.
The specified 63 A RCCB rating refers to rated current, not residual-current sensitivity. The required RCCB type and residual operating current must be checked against the actual fitted devices and installation requirements.
Tick the specs you need, then view products that match.
| Material | Steel | |
|---|---|---|
| Product Series | ABB Protecta Home | |
| Device Type | Distribution Board | |
| Incomer | Main switch / isolator + RCCB | |
| Number of Outgoing Ways | 8 | |
| Current | 63 A | |
| Product group | Protecta Home | |
| Product series | EPH | |
| ABB order code | 1TVC151800S3062 | |
| Manufacturer designation | EPH-S66208 8W 63A ISO 2x63A RC | |
| Product type | Split-load consumer unit | |
| Enclosure construction | Steel | |
| Number of ways | 8 | |
| Incoming main switch | 63 A switch disconnector | |
| Number of factory-fitted RCCBs | 2 | |
| Rated current of each RCCB | 63 A | |
| RCCB arrangement | Dual RCCB split load | |
| Split-load configuration | Variable/adaptable | |
| Nominal enclosure height | 250 mm | |
| Nominal enclosure width | 330 mm | |
| Nominal enclosure depth | 105 mm | |
| Enclosure colour | RAL 7035 light grey | |
| Shrouded busbar | Included | |
| Neutral bars | Included | |
| Protective earth bars | Included | |
| Installation instructions | Included | |
| Factory-fitted switching equipment | 63 A main switch | |
| Factory-fitted residual current protection | 2 x 63 A RCCBs | |
| Outgoing circuit breakers | Selected separately according to circuit requirements | |
| Applicable assembly standard | BS EN 61439-3 | |
| RCCB rated residual operating current | Confirm from ABB's device specification | |
| RCCB residual-current type | Confirm from ABB's device specification | |
| Rated operational voltage | Refer to the ABB product-specific technical documentation | |
| Rated short-circuit capability | Refer to the ABB assembly specification | |
| Degree of protection | Refer to ABB's product-specific enclosure documentation | |
| Installation environment | As permitted by the specified enclosure protection rating and ABB installation instructions | |
| EAN / GTIN | Not independently verified |
The ABB EPH-S66208 is an 8-way Protecta Home split-load consumer unit supplied with a 63 A main switch isolator and two 63 A RCCBs. It features a steel enclosure finished in RAL 7035 light grey.
The EPH-S66208 includes two factory-fitted RCCBs, each rated at 63 A, together with a 63 A incoming main switch. The RCCB residual-current sensitivity and type should be verified from ABB's device documentation.
The ABB EPH-S66208 has nominal enclosure dimensions of 250 mm high, 330 mm wide and 105 mm deep.
Yes. ABB specifies that its Protecta Home steel consumer unit assemblies include a shrouded busbar, neutral and earth bars, and installation instructions, together with the factory-fitted incoming switching and residual current protection equipment.
The standard EPH-S66208 is specified with a 63 A main switch and two 63 A RCCBs. Outgoing miniature circuit breakers are selected separately according to the circuit design and ABB's approved device compatibility requirements.
The ABB EPH-S66208 combines an eight-way split-load layout, a 63 A main isolator and two 63 A RCCBs in a compact RAL 7035 steel enclosure. Supplied with essential distribution components and designed to BS EN 61439-3, it provides a practical foundation for professional residential electrical distribution installations.
We use cookies