RX9363.215 Rittal RilineX NH fuse-switch disconnector 400A, 3-pole

RX9363.215 Rittal RilineX NH fuse-switch disconnector 400A, 3-pole

Rittal RX9363.215 RiLineX NH Size 2 fuse switch disconnector with electronic fuse monitoring, 400 A rated current and 690 V AC operating voltage for industrial power distribution.

SKU: RX9363.215Alt SKU: 9363215MPN: RX9363.215
Price
List Price £321.84 ex VAT
Your Price (ex VAT) Save 15%
£273.56 15% OFF
You save £48.28 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £273.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£273.56

Why Choose the Rittal RX9363.215 RiLineX NH Fuse Switch Disconnector?

The Rittal RX9363.215 is a heavy-duty RiLineX NH fuse switch disconnector engineered for mounting plate installation within industrial low voltage power distribution systems. It provides reliable circuit isolation, overcurrent protection and enhanced operational safety, making it ideal for switchgear assemblies, distribution boards and OEM control panels.

Part of the innovative Rittal RiLineX power distribution platform, the RX9363.215 features a lockable and sealable cover, integrated voltage measuring points, a maintenance park position and electronic fuse monitoring for rapid fault indication. These features help reduce maintenance time while improving operator safety and system availability.

Designed for NH Size 2 fuse links, the RX9363.215 supports applications up to 400 A with a rated operating voltage of 690 V AC. Its three-pole construction, M10 screw terminal connections and flexible top or bottom cable entry make it suitable for demanding industrial electrical installations.

Key Advantages

  • Designed for modern RiLineX power distribution systems.
  • 400 A rated operating current for demanding industrial applications.
  • Compatible with NH Size 2 fuse links.
  • Integrated electronic fuse monitoring for rapid fault detection.
  • Lockable and sealable cover enhances operational safety.
  • Integrated voltage measuring points for safe testing.
  • Tool-free cable outlet conversion between top and bottom entry.
  • Maintenance park position simplifies servicing.

Key Features

  • Rittal RiLineX series.
  • NH fuse switch disconnector for mounting plate installation.
  • NH Size 2 fuse compatibility.
  • 400 A rated operating current.
  • 690 V AC rated operating voltage.
  • 1,000 V rated insulation voltage.
  • Three-pole configuration.
  • M10 screw terminal connections.
  • Top or bottom cable outlet.
  • Electronic and visual fuse monitoring.
  • Lockable cover prepared for lead sealing.
  • Integrated voltage measuring points.
  • IP2XB contact protection.

Reliable Protection for Industrial Power Distribution

The Rittal RX9363.215 combines dependable circuit protection with safe manual isolation, making it an excellent choice for high-current industrial installations. When used with suitable NH Size 2 fuse links, it helps protect electrical equipment from overloads and short circuits while providing a clearly defined isolation point for maintenance.

Integrated electronic fuse monitoring provides immediate indication of a blown fuse, helping maintenance personnel identify faults quickly and minimise production downtime. Together with its lockable cover and maintenance park position, the RX9363.215 delivers enhanced safety and servicing convenience.

Typical Applications

  • Industrial power distribution systems.
  • Low voltage switchgear assemblies.
  • Motor control centres.
  • OEM machinery and automation equipment.
  • Manufacturing and processing plants.
  • Infrastructure and utility installations.
  • Commercial electrical distribution panels.

Technical Specifications

Tick the specs you need, then view products that match.

Product Series Rittal RiLineX
Device Type Terminal / feed-in
Current 400 A
Phase Three Phase
Poles 3-pole
Manufacturer Rittal
Series RiLineX
Model RX9363.215
Alternative SKU 9363215
Product type NH fuse switch disconnector
Installation Mounting plate assembly
Fuse size NH 2
Rated operating current 400 A
Rated operating voltage 690 V AC
Rated insulation voltage 1,000 V
Number of poles 3
Connection type M10 screw terminals
Cable outlet Top or bottom
Fuse monitoring Electronic and visual
Protection rating IP2XB
Material Polyamide (PA6) with silver-plated electrolytic copper contacts
Dimensions (H × W × D) approx. 298 × 209 × 129 mm
Operating temperature -5°C to +35°C
Storage temperature -25°C to +70°C
Weight approx. 3.3 kg
HS Code 85369095

Frequently Asked Questions

What is the Rittal RX9363.215 used for?

It is an NH fuse switch disconnector designed to provide safe circuit isolation and overcurrent protection in industrial power distribution systems.

Does the RX9363.215 include electronic fuse monitoring?

Yes. The unit includes both electronic and visual fuse monitoring to help identify blown fuse links quickly.

Which fuse size is compatible with this unit?

The RX9363.215 is designed for NH Size 2 fuse inserts.

What is the maximum rated current?

The switch disconnector has a rated operating current of 400 A.

Can the cable outlet be configured during installation?

Yes. The cable outlet can be positioned at either the top or bottom without tools, allowing greater installation flexibility.

Trusted by Electrical Engineers Worldwide